New RackUltra FX Features

Feature Release

New RackUltra FX Features

  • New Rhythm Delay FX.

Other New Features

  • CompStortion DEEP compressor model.
  • RF Integration Support for Shure SLX-D devices.
  • Group to Group routing.
  • Mute Group override.
  • Scene Safe overlay.
  • Peak Limiter 76 Gain Link mode.

Bug fixes

  • ID367 dLive MixPad / OneMix connection no longer causes errors in logs.
  • ID9230 Password can no longer be changed without entering password.
  • ID9237 Bank view could display incorrect information after a Show recall.
  • ID9268 Changing IP address of IP controllers could cause meters to freeze.
  • ID9270 Removing a mix assigned to PAFL Softkey no longer causes an error.
  • ID9281 Editing Scene descriptions could cause a touchscreen freeze
  • ID9502 Main Level change Action now correctly updates Stereo FX Sends.
  • ID9403 Fader bank controller now self-recovers from static discharge events.
  • ID9507 Input / Group sends to UFX channels now update correctly when
  • ganged.
  • ID9527 Mute Group page could show incorrect Stereo information.
  • ID9537 Combining Main faders when PEQ/GEQ ganged could cause no audio
  • to pass following reboot.
  • ID9244 First Relative Scene update following a Show recall or startup could fail
  • to update Scenes correctly.

Known Issues

  • ID7480 With DX boxes configured as ‘Connected’ offline, Director can show Offline
  • configuration when connected to a MixRack.
  • ID6928 Connection of a ME personal mixing system to the DX2 socket on
  • GX4816 is not supported.
  • ID6623 PAFL delay is reset after a Mixer Config change.
  • ID7484 Director restart required to connect to IP controllers when going from
  • Online to Offline.
  • ID7237 Sending a Scene Recall message to the MixRack MIDI/TCP port will
  • ignore Role Filters of connected Surfaces in a multi-surface setup.
  • ID8791 Touching both touchscreens at the same time can result in some menus
  • not working correctly.
  • ID8934 Trackpad drag adjustments may appear laggy in macOS Director.
  • ID362 dLive MixPad 2.00 doesn’t correctly indicate compressor state in gain
  • reduction meter.
  • ID9675 If any channel is currently in Mute Group override, pushing settings from
  • Director will cause DCA Mute LEDs to show incorrect indication.
  • ID9674 Surface may freeze following a MixRack disconnection requiring a
  • reboot.
  • ID9724 Recalling Mix Channel Library via an Action will not recall Group to Group
  • routing if Group to Group warning is enabled.
  • ID9718 Incorrect DCA mute LED state for certain channels when assigned to 2
  • DCAs, if Mute Group Override has been used.
  • ID8984 On rare occasions the Surface may timeout connecting to a MixRack.
  • Restarting the Surface will correct the issue.
  • ID9758 Scene updates in Director may fail to update compressors on stereo Mix