Via ControlSpace Designer: Newly added support features
Improvements
- Added support for Windows 11
- Added MSA12X health and status indicators in Project View
- Added guidance in MSA12X control panel to enable endpoint control
Changes
- MSA12X IP address is now set via Dante Controller
- Reduced time to go online in designs with multiple logic routes
- Improved input labels in MSA12X control panel
Bug fixes
General issues
- Fixed issue when EX and ESP processors do not acquire a link-local address when DHCP lease expires.
- Fixed issue changing network configuration on virtual NICs.
- Fixed issue updating MSA12X firmware.
- Fixed issue when successful MSA12X firmware update incorrectly reported as failed.
- Fixed issue reconnecting to MSA12X after firmware update.
- Fixed issue right-clicking on logic routes and audio routes in the Project Directory.
- Fixed issue moving PowerMatch and PowerShare-D signal processing blocks.
- Fixed issue generating missing loudspeaker EQ presets during ControlSpace Designer startup.
Audio Processing
- Fixed issue muting a matrix mixer input or output channel.
- Fixed issue copying mute state when duplicating a matrix mixer.
- Fixed issue copying matrix mixer mute state from the context menu.
- Fixed issue renaming multiple signal processing blocks from the context menu.
- Fixed issue displaying ATS value in Gated AMM signal processing blocks with more than 16 channels.
- Fixed issue repeatedly clicking a boundary wall in the Standard Room Combiner control panel.
- Fixed issue when wires connected to Room Combine Inputs may disappear when deleting a Standard Room Combiner signal processing block.
- Fixed issue displaying the Enhanced AGC Total Gain as 60 dB without signal.
- Fixed issue displaying AEC references in Project Directory.
Control
- Fixed issue entering an incomplete Serial Out IP address.
- Fixed issue validating Serial Out IP addresses.
3rd Party Devices
- Fixed issue copying TCC2 LED color and brightness state
- Fixed issue operating TCC2 control panel while CSD is online.
- Fixed issue allowing TCC2 logic blocks to be assigned to Parameter Sets and Timers.
Logic
- Fixed issue displaying correct Serial Out logic connector state via the control panel and serial command.
Dante
- Fixed issue when Dante endpoint subscriptions may not be created when opening a project file.
- Fixed issue displaying imported Dante firmware files in Dante Updater as available for update. Resolved with Dante Updater 4.6.
- Fixed issue when disconnected Dante endpoints show partial settings in Hardware Manager.
- Fixed issue displaying Dante endpoints configured with static IP addresses in uppercase in Hardware Manager.
Open issues
Signal Processing
If a USB Input module is not wired to an Output module, that module will not show metering data.
ControlSpace Designer Logic Blocks
- Assigning a logic action from an ESP-00 to a trigger on an EX-1280 will result in an error.
- The states of logic connectors within the Logic Wiring View may sometimes show the incorrect state. This does not affect the functionality.
- If you are experiencing issues with go-online time or ControlSpace Designer crashes when going online, consider dragging and dropping logic blocks instead of copying and pasting them.
- If you are finding ControlSpace Designer crashes when going online with a large number of logic routes, try going online from Project View.
Dante Endpoints
- The EX-8ML may boot up with a link-local address upon first use rather than DHCP. Rebooting the device will then revert the address to DHCP.
Telephone Call Functionality
- PSTN and VoIP ring and voice levels are not being properly set. There is no difference in audible level between 0 dB and +10 dB.
ControlSpace Remote
- On an Avaya system, it is not possible to end a VoIP call with ControlSpace Remote when the far end is in a hold state.
Other Issues
- When programming selectors, gains, analog inputs/outputs for digital GPI, they may not function when using EX-1280C with legacy devices.
- PowerMatch will not alert the use