The manufacturer Bose has set up its devicebase profile. Contents like updates, compatibilities and support are maintained regularly.
Update

Newly added support features and bug fixes

Improvements

  • Added support for Windows 11
  • Added MSA12X health and status indicators in Project View
  • Added guidance in MSA12X control panel to enable endpoint control

Changes

  • MSA12X IP address is now set via Dante Controller
  • Reduced time to go online in designs with multiple logic routes
  • Improved input labels in MSA12X control panel

Bug fixes

General issues

  • Fixed issue when EX and ESP processors do not acquire a link-local address when DHCP lease expires.
  • Fixed issue changing network configuration on virtual NICs.
  • Fixed issue updating MSA12X firmware.
  • Fixed issue when successful MSA12X firmware update incorrectly reported as failed.
  • Fixed issue reconnecting to MSA12X after firmware update.
  • Fixed issue right-clicking on logic routes and audio routes in the Project Directory.
  • Fixed issue moving PowerMatch and PowerShare-D signal processing blocks.
  • Fixed issue generating missing loudspeaker EQ presets during ControlSpace Designer startup.

Audio Processing

  • Fixed issue muting a matrix mixer input or output channel.
  • Fixed issue copying mute state when duplicating a matrix mixer.
  • Fixed issue copying matrix mixer mute state from the context menu.
  • Fixed issue renaming multiple signal processing blocks from the context menu.
  • Fixed issue displaying ATS value in Gated AMM signal processing blocks with more than 16 channels.
  • Fixed issue repeatedly clicking a boundary wall in the Standard Room Combiner control panel.
  • Fixed issue when wires connected to Room Combine Inputs may disappear when deleting a Standard Room Combiner signal processing block.
  • Fixed issue displaying the Enhanced AGC Total Gain as 60 dB without signal.
  • Fixed issue displaying AEC references in Project Directory.

Control

  • Fixed issue entering an incomplete Serial Out IP address.
  • Fixed issue validating Serial Out IP addresses.

3rd Party Devices

  • Fixed issue copying TCC2 LED color and brightness state
  • Fixed issue operating TCC2 control panel while CSD is online.
  • Fixed issue allowing TCC2 logic blocks to be assigned to Parameter Sets and Timers.

Logic

  • Fixed issue displaying correct Serial Out logic connector state via the control panel and serial command.

Dante

  • Fixed issue when Dante endpoint subscriptions may not be created when opening a project file.
  • Fixed issue displaying imported Dante firmware files in Dante Updater as available for update. Resolved with Dante Updater 4.6.
  • Fixed issue when disconnected Dante endpoints show partial settings in Hardware Manager.
  • Fixed issue displaying Dante endpoints configured with static IP addresses in uppercase in Hardware Manager.

Open issues

Signal Processing

  • If a USB Input module is not wired to an Output module, that module will not show metering data.

ControlSpace Designer Logic Blocks

  • Assigning a logic action from an ESP-00 to a trigger on an EX-1280 will result in an error.
  • The states of logic connectors within the Logic Wiring View may sometimes show the incorrect state. This does not affect the functionality.
  • If you are experiencing issues with go-online time or ControlSpace Designer crashes when going online, consider dragging and dropping logic blocks instead of copying and pasting them.
  • If you are finding ControlSpace Designer crashes when going online with a large number of logic routes, try going online from Project View.

Dante Endpoints

  • The EX-8ML may boot up with a link-local address upon first use rather than DHCP. Rebooting the device will then revert the address to DHCP.

Telephone Call Functionality

  • PSTN and VoIP ring and voice levels are not being properly set. There is no difference in audible level between 0 dB and +10 dB.

ControlSpace Remote

  • On an Avaya system, it is not possible to end a VoIP call with ControlSpace Remote when the far end is in a hold state.

Other Issues

  • When programming selectors, gains, analog inputs/outputs for digital GPI, they may not function when using EX-1280C with legacy devices.
  • PowerMatch will not alert the use
Receive Important Update Messages Stay tuned for upcoming Bose EX-UH updates

Was the content helpful to you?