The manufacturer Bose has set up its devicebase profile. Contents like updates, compatibilities and support are maintained regularly.
Update

New progress bar information when retrieving a design file.

Improvements

PSX amplifiers: PSXProxy - allows for the control of PowerShareX parameters using ParameterSets, ParameterSet Lists, Timers, Groups, GPI, Serial I/O, Serial Control, and controllers including CC-16/64/xD, and CSR 3.1.

  • ParameterSets – Each signal processing block of the PSX amplifier can be registered to a Parameter Set
  • ParameterSet Lists – The parameters of each signal processing block of the PSX amplifier can be changed by recalling a ParameterSet via the ParameterSet List.
  • Timers - The “Level” and “Mute” parameters of each PSX Output block may be registered to a Timer.
  • Groups (Level and Mute) - The “Level” and “Mute” parameters of each PSX Output block may be registered to a Group. They may be grouped across multiple PSX amplifiers as well as with PowerMatch and PowerShareD amplifiers and controlled together by a master fader.
  • Groups (Signal Processing blocks) - The parameters of each signal processing block (such as two or more parameteric EQ
  • GPI - The “Level” and “Mute” parameters of each PSX Output block may be registered in “’Digital Control Input,’ Digital Up/Down,’ ‘Analog (+) Control Input,’ or ‘Analog (-) Control Input’” of the “GP In” of EX/ESP processors.
  • Serial Input - The “Level” and “Mute” parameters of each PSX Output block may be registered in “Serial Input ON” or “Serial Input OFF” of the “Serial In” of EX/ESP processors.
  • Serial Control – PowerShareX devices can be controlled via serial commands sent over Ethernet using a TCP/IP connection via the RTC (EX/ESP processor) and a specified port number. See the Serial Control Protocol 5.15 guide for more information.
  • CC-16/64/xD - The “Level” and “Mute” parameters of each PSX Output block or “Grouped” Output blocks may be registered to the “Volume Control” of ControlCenter controllers.
  • CSR 3.1 - The “Level” and “Mute” parameters of each PSX Output block may be added to a canvas via ControlSpace Remote. Input and Output meters, ParameterSets, ParameterSet Lists, and Groups associated with PSX amplifiers may also be added to the canvas.

New Tools menu option - “Run PSXProxy on PC”

  • This option is available for larger systems. It is forced on when the number of
    amplifiers in the design exceeds the threshold of the processor

New Tools menu option - “CPU Resources”

  • This option displays the calculated CPU resources associated with an EX/ESP
    processor

Changes

  • Added a new help file topic: PSX Proxy.
  • ControlSpace Serial Control Protocol updated for v5.15.
  • Updated PSX “Measure Load” control panel UI options and performance for improved system diagnostics.
  • Prior to selecting devices for network connection when going online a new progress bar will display.
  • New progress bar information when retrieving a design file.

Defect Fixes

  • Fixed a defect that resulted in “Toggle Standby” option appearing enabled when offline.
  • Fixed a defect that resulted in EX-4ML/EX-8ML becoming unresponsive with CSD open.
  • Fixed a defect in the PowerShareX alarm UI that resulted in the detected impedance value overrunning the ohm symbol.
  • Fixed defects in the Matrix control panel of PowerMatch and PowerShareX amplifiers.
  • Fixed a defect in EX processors that resulted in the content of “Digital Control Input 1” of “GP In” becoming lost.
  • Fixed a defect that resulted in several MSA12X control becoming erroneously enabled.
  • Fixed a defect that resulted in the standby parameter for MSA12X not updating when changed via ParameterSet.
  • Fixed a defect that resulted in small values being reported when measuring the load of an output in PowerShareX amplifiers.
  • Fixed a defect for PowerMatch amplifiers where “Out 1” could not be registered to Timers 1 – 16.
  • Fixed a defect that resulted in certain operations of a CRR caused CSD to crash.
  • Fixed a defect that allowed two RTC devices to exist in a system design.
  • Fixed a defect that disabled the test button for “GP In 5” in EX processors.
  • Fixed a defect that resulted in subordinate output channels of V-bridge/I-Share/Quad registering to “Serial In” / “GP In” / “Timers”.
  • Fixed a defect that resulted in some processor input blocks moving after connecting a CC-16.
  • Fixed a defect that resulted in parameters registered to “Volume” of a CC_16 not deleting appropriately.
  • Fixed a defect that resulted in the maximum value of Property of the controls of the CC-64 is
    reset to the default value.
  • Fixed a defect that resulted in the maximum value of Volume of the controls of the CC-16 is reset to the default value.
  • Fixed a defect that resulted in the maximum value of Volume of the controls of the CC-xD is reset to the default value.
  • Fixed a defect that resulted in the maximum value of Property of the controls of the CC-xD is not correct for PowerMatch or PowerShare-D.
  • Fixed a defect that resulted in the maximum value of the range setting of “GP In” in EX processors is reset to the default value.
  • Fixed a defect that caused a firmware error when “Get from device(s)” was used and an MSA12X stack was in the project file.
  • Fixed a defect that resulted in only the Project View sometimes being displayed after starting CSD.
  • Fixed a defect that resulted in the warning dialog not appearing after deteling a Dante endpoint block.
  • Fixed a defect that resulted in some MSA12X parameters not saving to the .csp file.
  • Fixed a defect that caused copy/paste parameters to not work for MSA12X.
  • Fixed a defect that resulted in the warning dialog not indicating old PSX firmware when scanning.
  • Fixed a defect that resulted in the adjustment of time in by the ntp in an EX processor is not performed.
  • Fixed a defect that resulted in telemetry information not sending to ControlSpace Cloud.
  • Fixed a defect that caused the mute in CC-64 simulator not reflecting correctly when controlled by CC-64 mute.
  • Fixed a defect that resulted in the limiter’s threshold of PowerShare-D amplifiers not reacting to the mouse wheel.
  • Fixed a defect that caused “Copy Parameters” to not appear in the context menu for PowerMatch and PowerShareX amplifiers.
  • Fixed a defect that resulted in ParameterSet List selection by ParameterSet not working correctly on hardware.
  • Fixed a defect that resulted in a Limiter’s gain reduction meters in PowerShareX amplifier freezing.
  • Fixed a defect in PowerShareD amplifiers that resulted in incorrect frequency responses when speaker presets were used
Receive Important Update Messages Stay tuned for upcoming Bose PowerMatch Series updates

More from the Audio Technology section

Was the content helpful to you?