The manufacturer Cisco has not yet set up its devicebase profile. Content such as updates, compatibilities and support may only be maintained with a delay.
Update

Multiple new upgrades and enhancements Part 2

Bug fixes

CSCvz42028 - In some cases, in PVST mode the output from the command "show spanning-tree active vlan " may show access ports that do not belong to the specified VLAN

CSCwc39424 - After about 2 hours SNTP stops polling SNTP servers that were configured by hostname

CSCwc39428 - Wrong LDP MAC-PHY TLV value for 2.5 and 10G interfaces

CSCwc39431 - Following a stack switchover to a Standby unit, the Probe does not automatically reconnect to CBD Dashboard

CSCvu81808 - In some cases, an ACE will be deleted if edited via GUI

CSCwc39432 - Auto negotiation of MAC/PHY configuration/Status TLV indicates disable although the interface is set to auto-negotiation

CSCwc39434 - After importing a CA certificate with "tab" characters through the GUI, the "signer" CA will be displayed twice

CSCwc39437 - PoE settings and statistics page display on the GUI is very slow

CSCwc39514 - When switching a DHCPv6 client from a VLAN interface to a physical interface, the device may crash in some cases

CSCwc39515 - Command renew dhcp oob fails if previously the OOB interface declined an address due to conflict with default IP on VLAN 1

CSCwc39531 - Login via CBD mobile app fails if device credentials are added/changed via GUI

CSCwb57285 - A Class0-4 PoE PD with low priority and no LLDP negotiated may reboot when a Class4 PD is plugged in

CSCvz97713 - CBS250-8P-E-2G - The link flaps and "denied counter" increments in PoE

Known Issues

CSCwc39517 - After a brief power outage, the switch may occasionally fail to respond. CBS350-24XTS is the only SKU with this symptom

CSCwc39527 - On some platforms legacy PoE PDs are detected as 802.3AT instead of 802.3AF

CSCwc39529 - Sometimes I2C related messages are generated when inserting SFP GLC-BX, GLC-BX-D or MGBLX1-V2-1G transceivers

CSCwc44155 - Backup Dashboard data to USB before enabling CBD, as "File operations" on the web page become invalid

CSCwc39519 - Login Attack prevention- the failed login attempt count, time period and quite mode are reset when an active unit switchover occurs

CSCwc39521 - When setting VLAN1 to static IP address 192.168.1.254 and quickly pinging another device the ping fails

CSCwc39522 - Unable to access device GUI management if device software is downgraded from 3.2.0.x to 3.1.1.7 or lower version – unless user removes browser cookies

CSCwc39527 - On some platforms legacy PoE PDs are detected as 802.3AT instead of 802.3AF

CSCwc39529 - I2C related messages are generated when inserting SFP GLC-BX, GLC-BX-D or MGBLX1-V2-1G transceivers

CSCwc39530 - Certificate revocation configuration is missing from the configuration file after upgrading from an earlier version to version 3.1.1.7

Version: 3.2.0.84 Link
Receive Important Update Messages Stay tuned for upcoming Cisco Business 250 Series updates

Was the content helpful to you?

Advertisement Advertise here?