Bug fixes and workarounds
Bug fixes
CSCwd60295 - WrongSTP output may be visible ifSTP is disabled and mode is set toPVST or RPVST.
CSCwe64339 - Management ACL generates error for built-in probe.
CSCwe64160 - FATAL error when enabling MSTP and show spanning-tree detail on a stack.
CSCwd59624 - The "SmartPort is enabled" line must be removed from the "display macro auto ports" command.
Known issues
CSCwe76469
Symptom
- CBD probe does not respond when HTTPs port is changed.
Workaround
- After changing the HTTPs port, disable the CBD probe and then enable it again, or set the CBD
- probe with the CLI command "cbd reset" or the WEB GUI button "Reset Connection".
CSCwe76605
Symptom
- On the CBD settings page, the plain text input field for the Access Key Secret is grayed out.
Workaround
- Click on the plaintext field, then change to encrypted, then back to plaintext.
CSCwe87662
Symptom
- Cannot start the CBD Connection Wizard on a standalone device with device ID 2.
Remedy
- Configure as device 1.
CSCwe87686
Symptom
- Sometimes the "clear ipv6 neighbor binding table" command can cause unexpected log messages on the console.
Workaround
- None