Update

Multiple new upgrades and enhancements Part 2

Bug fixes

CSCvz42028 - In some cases, in PVST mode the output from the command "show spanning-tree active vlan <#>" may show access ports that do not belong to the specified VLAN

CSCwc39424 - After about 2 hours SNTP stops polling SNTP servers that were configured by hostname

CSCwc39428 - Wrong LDP MAC-PHY TLV value for 2.5 and 10G interfaces

CSCwc39431 - Following a stack switchover to a Standby unit, the Probe does not automatically reconnect to CBD Dashboard

CSCvu81808 - In some cases, an ACE will be deleted if edited via GUI

CSCwc39432 - Auto negotiation of MAC/PHY configuration/Status TLV indicates disable although the interface is set to auto-negotiation

CSCwc39434 - After importing a CA certificate with "tab" characters through the GUI, the "signer" CA will be displayed twice

CSCwc39437 - PoE settings and statistics page display on the GUI is very slow

CSCwc39514 - When switching a DHCPv6 client from a VLAN interface to a physical interface, the device may crash in some cases

CSCwc39515 - Command renew dhcp oob fails if previously the OOB interface declined an address due to conflict with default IP on VLAN 1

CSCwc39531 - Login via CBD mobile app fails if device credentials are added/changed via GUI

CSCwb57285 - A Class0-4 PoE PD with low priority and no LLDP negotiated may reboot when a Class4 PD is plugged in

CSCvz97713 - CBS250-8P-E-2G - The link flaps and "denied counter" increments in PoE

Known Issues

CSCwc39517 - After a brief power outage, the switch may occasionally fail to respond. CBS350-24XTS is the only SKU with this symptom

CSCwc39527 - On some platforms legacy PoE PDs are detected as 802.3AT instead of 802.3AF

CSCwc39529 - Sometimes I2C related messages are generated when inserting SFP GLC-BX, GLC-BX-D or MGBLX1-V2-1G transceivers

CSCwc44155 - Backup Dashboard data to USB before enabling CBD, as "File operations" on the web page become invalid

CSCwc39519 - Login Attack prevention- the failed login attempt count, time period and quite mode are reset when an active unit switchover occurs

CSCwc39521 - When setting VLAN1 to static IP address 192.168.1.254 and quickly pinging another device the ping fails

CSCwc39522 - Unable to access device GUI management if device software is downgraded from 3.2.0.x to 3.1.1.7 or lower version – unless user removes browser cookies

CSCwc39527 - On some platforms legacy PoE PDs are detected as 802.3AT instead of 802.3AF

CSCwc39529 - I2C related messages are generated when inserting SFP GLC-BX, GLC-BX-D or MGBLX1-V2-1G transceivers

CSCwc39530 - Certificate revocation configuration is missing from the configuration file after upgrading from an earlier version to version 3.1.1.7

Version: 3.2.0.84 Link
Receive Important Update Messages Stay tuned for upcoming Cisco Business 350 Series updates
The manufacturer Cisco has not yet set up its devicebase profile. Content such as updates, compatibilities and support may only be maintained with a delay.

Was the content helpful to you?

Advertisement Advertise here?
Udemy IT certification ad