Update

Big changes in the new update

Improvements:

  • Added support for reading multiple Maxicode symbols.
  • Added a DotCode option to the Symbology Group drop-down, enabling decoding of DotCode symbols.
  • Added an Aztec Code option to the Symbology Group drop-down, enabling decoding of Aztec Code symbols.
  • Added an MSI checkbox to the 1D Symbologies, to enable MSI (also known as Modified Plessey) reading.
  • Added a Code 25 checkbox to the 1D Symbologies, to enable Code 25 (also known as Code 2 of 5) reading.
  • Added a Severe Perspective option to the Decode Settings Perspective drop-down, to decode Data Matrix symbols with severe perspective distortion at reading time.
  • Added a Symbol Damage drop-down to the Decode Settings, to enable 2DMax and PowerGrid and allow reading of low-quality Data Matrix and QR symbols, including symbols with damage to their quiet zones, finder patterns, and clocking patterns.
  • Added a Rectangular Extension checkbox to the Decode Settings, to specify whether the Data Matrix symbol is decoded using Data Matrix Rectangular Extension (DMRE), for symbols used in applications with high data density and limited vertical space available for marking the code.
  • Added a Minimum Decodes Before Output drop-down to the Decode Settings, to specify the number of matching decodes for a successful read of the 1D symbol

Resolved Issues:

  • The GetAllTime Vision Data Access spreadsheet function has been updated to include the preinspection time before the job executes, to more accurately report the time for the image to be acquired and the job to execute.
  • When communicating over TCP/IP or UDP, the QueryDevice spreadsheet function now correctly updates to display the data read back from the TCP/IP or UDP device. Previously, the QueryDevice function only updated if it contained an invalid input parameter and returned #ERR
  • The status bar in the Spreadsheet View and the Results tab in the EasyBuilder View Palette have been updated to display the job execution time and total execution time. The total execution time is the job execution plus any additional pre-inspection and post-inspection time.
  • When the Acquire button is pressed in the Spreadsheet View Profile Job dialog, the Total time correctly displays the job execution time.
  • When using the BeadFind and BeadInspect spreadsheet functions, the bead path no longer always must intersect the bead to correctly find the bead. During the inspection, the bead may move, and both edges of the bead may be positioned on one side of the bead path. Previously, the bead would not have been detected and a “No Bead Found” error was reported.

Open Issues:

  • If the ReadIDMax function is configured to read Data Matrix symbols, the Enable Training option is checked and Train Perspective is selected from the Perspective drop-down, subsequent attempts to read the symbol will fail.
  • Sending the communication settings, such as the IP address, from Mitsubishi iQ Sensor Solution (GX Works) to the In-Sight vision system/sensor is not supported.
  • When you try to connect your vision system/sensor to the Web HMI for the first time, you may receive a permission error, and the connection is denied.
  • For In-Sight 7000 Gen2 series and 9000 series vision systems configured for CIP-Sync/PTP, 1588 synchronization accuracy through a transparent clock-switch might increase to more than 10µs offset from the master.
  • If an industrial Ethernet communication protocol triggers the vision system, the JobPass signal is sent only if the job contains a WriteResultsBuffer function. This issue does not occur with EasyBuilder applications once the Communication application step has been configured.
Receive Important Update Messages Stay tuned for upcoming Cognex In-Sight 8000 updates