The manufacturer Crestron has not yet set up its devicebase profile. Content such as updates, compatibilities and support may only be maintained with a delay.
Update

Updated 3rd party lighting driver support

  • CP4-R V1: Please confirm that your processor is a V1 model before loading FW manually. To confirm, connect to the processor via text console in Toolbox and issue the command "ver -v". The model number on the first line will show "CP4-R Cntrl Eng". If wrong file is used there are no side effects, and the Firmware upgrade will fail.
  • CP4-R V2: Please confirm that your processor is a V2 model before loading FW manually. To confirm, connect to the processor via text console in Toolbox and issue the command "ver -v". The model number on the first line will show "CP4-R (HW Ver 2) Cntrl Eng". If wrong file is used there are no side effects, and the Firmware upgrade will fail.

New Features

  • Added support for the Crestron DM-NAX-4ZSA-50
  • Added support for the Crestron DM-NAX-XSP
  • Added support for the Crestron DM-NAX-BTIO-1G
  • Added support for the Crestron DM-NAX-2XLRI-1G
  • Added support for the Crestron DM-NAX-AUD-USB
  • Added support for the Crestron DM-NAX-AUD-IO
  • Added support for the Crestron HD-MD2x1-8K
  • Added the ability to manage blocked users and IP addresses via the Crestron Concierge Service found on the myCrestron portal
  • Improved the capabilities of the device health dashboard available via the Crestron Concierge Service found on the myCrestron portal
  • Added support for Lutron processor model HQP7-RF-2
  • Updated 3rd party lighting driver support to import scenes from 3rd party lighting ecosystems
  • Refer to the driver release notes to determine if the driver supports this feature
  • Added new button feedback for scenes called “On When Any Device On/Open”. This will drive feedback high on the button when any device that supports a scene is in the on/open
  • Updated the “Check for Driver Update” button found in the settings for drivers to indicate that the driver can be disabled
  • Added the ability to assign NETGEAR switches to PDU outlets
  • Added the ability to add and configure Digital I/O Control Modules and Interface Cards via the myCrestron Pre-configuration Tool
  • Added the ability to associate HZ2-AUX keypads with their parent device via the myCrestron Pre-configuration Tool
  • Improved product filter on the search capability in the myCrestron Pre-configuration Tool

Bug Fixes and Behavior Changes

  • Resolved intermittent issues where the child processor would go offline with the parent processor.
  • Resolved rare issue where keypads imported from a child processor reported offline
  • Resolved issue where shade limits could be lost after a processor upgrade
  • Fixed issue with fan controls showing in the Crestron Home application when HZ-THSTAT was not FCU mode
  • Resolved issue where the web interface launcher for Crestron Devices would not function if the network range of the system changed
  • Fixed issue where keypad feedback could blink indefinitely when programmed to control a CLC-1LEDPWM-RGB-EX
  • Resolved issue where after upgrading the processor multiple virtual instances of a gateway could be shown
  • Fixed intermittent issues where user could not discover an apple TV when using the Homekit driver
  • Resolved issue where min and max values on the DIN-A08 will not properly be saved when set via the Crestron Home Setup application
  • Resolved issue where IR devices connected to a C2N-IO would no longer function after a Cresnet scan
  • Resolved issue where tunable lights were not properly changing their values after a user selects “Set all lights in the room to these settings” from the Crestron Home application
  • Fixed routing issue related to rooms that have two separate audio endpoints for the sources located in the room
  • Resolved issue on the paging UX showing empty groups after moving panels between rooms
  • Resolved issue with Scenes not properly functioning if a load included in the scene has been made virtual
  • Resolved a rare issue where Crestron gateways could go offline with the processor after a reboot
  • Resolved a rare issue where Crestron battery shades may move without user interaction
  • Resolved issue with BACnet thermostats not properly turning off when prompted from the Crestron home application
  • Resolved issue with “All Off” scene feedback staying lite when feedback is set to “On when any light on”
  • Resolved issue where HZ-THSTATs could be blocked from communicating with the Crestron Home processor
Version: 4.001.0330 Link
Receive Important Update Messages Stay tuned for upcoming Crestron CP4-R updates

Was the content helpful to you?

Advertisement Advertise here?
Basalte Fibonacci Banner