The manufacturer Crestron has not yet set up its devicebase profile. Content such as updates, compatibilities and support may only be maintained with a delay.
Update

Updated WebUI to match new “Common Config UI” on all Crestron devices.

Improvements

  • Added support for TLS1.3. Read the “Important Information” section for more details.
  • Updated WebUI to match new “Common Config UI” on all Crestron devices.
  • Added the ability for the control system to automatically restart after regenerating a self-signed certificate after the previous self-signed certificate had expired. Read the “Important Information” section for more details.
  • Upgraded OpenSSH to 9.8p1
  • Added AUPEERVERIFY console command, to enable/disable peer verification for AutoUpdate.
  • Added NTLM Authentication for Proxy. This is only a valid option when FIPS mode is disabled.
  • Added support for remote debugging a .NET6 or .NET8 program using Microsoft Visual Studio. See https://community.crestron.com/s/article/3102 for more information.

Bug fixes

  • Resolved the issue with HomeKit due to the upgrade to OpenSSL 3.0 in firmware 2.8005.00031
  • Resolved the issue with DSC PowerSeries Neo drivers that was introduced in 2.8005.00031
  • Resolved an issue with WebSocketClient class not updating connection state change after physically disconnecting network from device.
  • Resolved an issue in the WebUI that didn’t allow 192.168.0.0/22 to be set as IP address for Control Subnet.
  • Resolved an issue that prevented creating the Broadcast Distribution Table for BACnet.
  • Domain group using Active Directory would fail to be removed from WebUI
  • SNMP SysDescr OID was not populated with the correct value
  • Resolved an issue with the Serial Pacer symbol
  • Resolved an issue with USB-Ethernet link status on RMC4
  • Resolved an issue that prevented the time from being maintained after power was removed.• PROGINFO console command didn’t show all information correctly.
  • Adjusted time zone for Paraguay
  • Resolved an issue that triggered an MC4 to reboot when using the ENERGYSCAN command
  • Resolved an issue that prevented a SIMPL program from adjusting DNS settings
  • Resolved an issue with the AutoUpdate manifest URL that could cause a command injection vulnerability.
  • Resolved an issue with UDP sockets not always being opened correctly on the LAN port of a Control Subnet based control system.
  • Improved response speed of CWS requests on .NET6 / .NET8
  • Resolved an issue that incorrectly displayed headers from a CWS request on .NET6 / .NET8
  • Resolved an issue with CrestronEnvironment.SystemInfo.TotalRamSize and CrestronEnvironment.SystemInfo.TotalRamFree that could lead to a program crash. Please read the “Important Information” section for more details.
Version: 2.8006.00110.01 Link
Receive Important Update Messages Stay tuned for upcoming Crestron CP4 updates

More from the Media Control section

Was the content helpful to you?

Advertisement Advertise here?
Udemy IT certification ad