Updated WebUI to match new “Common Config UI” on all Crestron devices.
Improvements
- Added support for TLS1.3. Read the “Important Information” section for more details.
- Updated WebUI to match new “Common Config UI” on all Crestron devices.
- Added the ability for the control system to automatically restart after regenerating a self-signed certificate after the previous self-signed certificate had expired. Read the “Important Information” section for more details.
- Upgraded OpenSSH to 9.8p1
- Added AUPEERVERIFY console command, to enable/disable peer verification for AutoUpdate.
- Added NTLM Authentication for Proxy. This is only a valid option when FIPS mode is disabled.
- Added support for remote debugging a .NET6 or .NET8 program using Microsoft Visual Studio. See https://community.crestron.com/s/article/3102 for more information.
Bug fixes
- Resolved the issue with HomeKit due to the upgrade to OpenSSL 3.0 in firmware 2.8005.00031
- Resolved the issue with DSC PowerSeries Neo drivers that was introduced in 2.8005.00031
- Resolved an issue with WebSocketClient class not updating connection state change after physically disconnecting network from device.
- Resolved an issue in the WebUI that didn’t allow 192.168.0.0/22 to be set as IP address for Control Subnet.
- Resolved an issue that prevented creating the Broadcast Distribution Table for BACnet.
- Domain group using Active Directory would fail to be removed from WebUI
- SNMP SysDescr OID was not populated with the correct value
- Resolved an issue with the Serial Pacer symbol
- Resolved an issue with USB-Ethernet link status on RMC4
- Resolved an issue that prevented the time from being maintained after power was removed.• PROGINFO console command didn’t show all information correctly.
- Adjusted time zone for Paraguay
- Resolved an issue that triggered an MC4 to reboot when using the ENERGYSCAN command
- Resolved an issue that prevented a SIMPL program from adjusting DNS settings
- Resolved an issue with the AutoUpdate manifest URL that could cause a command injection vulnerability.
- Resolved an issue with UDP sockets not always being opened correctly on the LAN port of a Control Subnet based control system.
- Improved response speed of CWS requests on .NET6 / .NET8
- Resolved an issue that incorrectly displayed headers from a CWS request on .NET6 / .NET8
- Resolved an issue with CrestronEnvironment.SystemInfo.TotalRamSize and CrestronEnvironment.SystemInfo.TotalRamFree that could lead to a program crash. Please read the “Important Information” section for more details.