The manufacturer Crestron has not yet set up its devicebase profile. Content such as updates, compatibilities and support may only be maintained with a delay.
Update

Adds Support for a Couple Of Devices Along With Quality Fixes

Improvements

  • Added support for the following products:
    • DM-NVX-E10
    • DM-NVX-E20
    • DM-NVX-D10
    • DM-NVX-D20

Bug fixes

  • Improved POE power negotiation where a continual reboot may occur
  • Added default NAX session name so it will no longer be blank
  • Resolved an issue where DM‐ NVX‐ Director will not come online when port mapping is enabled
  • Improved background image aspect ratio for products that support this feature
  • The Under‐ scan drop down now reflects proper value (Scaler models only)
  • Resolved an issue where the domain name was not being displayed properly
  • NAX audio may be lost if the video Multicast address was set to 0.0.0.0
  • Resolved a device response timeout error when changing device credentials
  • Test pattern generator renders images properly for all resolutions (Supported models only)
  • Security improvements
    • Eliminated a command injection vulnerability from the background image server path
    • Ensured SNMP updates are available when FIPS mode is enabled

Open issues

  • An API change was made in version 6 that modified the stream name from "stream1" to "stream01". A leading zero was incorporated to ensure uniformity across product lines.
  • Some Logitech cameras may have poor audio quality when routed through NVX USB extension
  • In some cases, removing and adding background images may cause a random loaded image to appear. This can be resolved by ing a specific image after loading new images.
  • Clearing the OSD while the feature is enabled, may leave the first character. Setting the feature "off" will resolve this issue.
  • When changing endpoints from point to point mode to traditional configuration, the multicast address will need to be manually changed.
  • Authentication screen may be displayed after a reboot. A refresh may be required to clear this error
  • When downgrading to 4.x or below, you will not be able to create a custom EDID entry in the lower FW version. All other entries will remain operational.
  • When upgrading the DM‐ NVX‐ 35x, if analog audio was the ed audio source, it may revert to "Audio Follows Video". This can be resolved in the web UI, or via SIMPL programming.
  • Streaming settings cannot be changed on the web interface when Statistics are enabled.
  • Unable to delete Active Directory groups with "/" included in the name of the group.
  • When a CA certificate is added to the web interface, the page must be manually refreshed in order to update the list.
  • The DM‐ NVX requires Username/Password for 802.1x "EAP‐ TLS Certificate."
  • Crestron recommends using Google Chrome for firmware updates. When using other browsers, the firmware update may report as failed although it has actually succeeded. Check the firmware version in the status page to confirm a successful firmware update.
  • DM‐ NVX‐ 351 and 363 are unable to down mix some s of Dolby Atmos (MAT 2.0) and DTSX to PCM 2ch audio.

Version: 6.0.4835.00046 Link
Receive Important Update Messages Stay tuned for upcoming Crestron DM-NVX-360 updates