New centralized import functionality for Device Certificates

New features

User Interface and Functionality

  • New login mechanism via id.knx.org (Based on OAuth2 and possibility to enable the 2FA)
  • Project Password Manager
  • Licensed App can be now downloaded directly within ETS
  • Multiple Apps can be now licensed at the same time
  • New centralized import functionality for Device Certificates
  • SDK and App-related improvements for ETS 6.3

Improvements

User Interface & Functionality

  • Change Main Window Tab Bar to have a Title Tab where the currently used license, version, and build number are shown
  • Certificate dialog: Allow selecting an external camera to scan a device certificate
  • Rearrange the 'burger' menu and the button spacings of the workplace
  • Improvements for handling bus interface associations
  • Updates on the Manufacturer license types (The management URL is here)
  • Multiple Windows Improvements
  • Security Proxy Improvements
  • Improved KNX Secure Workflows for 6.3
  • Improve KNX IoT Point API Support
  • Improvements to Online Diagnostics tools
  • Project Archive Improvements
  • Allow to enter the actually assigned IP address for KNXnet/IP devices
  • Allow to link Group Ranges to Bus Interfaces
  • Deprecation the "Current Line" functionality in ETS6
  • Deprecation of free level group address structure
  • Deprecation of Manual Filter Tables
  • ETS6 is wrongly claiming that a device is having a download plugin and Compatibility Mode would be required
  • Group Address Panel --Allow to copy and paste one group address association to another
  • Re-enable max associations validations
  • Update NonRegRelevantData also when versions are equal
  • Add list of services and list of tasks to Diagnostic output
  • Allow Group Address write for multiselections for identical datapoint types
  • Allow IP routers with non-matching medium type to be added to the building part
  • Allow editing of tags for password protected projects
  • Automatically restart ETS after App-uninstallation
  • Busload indication drop to 0 after some time
  • Do not show update information if the running ETS version is newer
  • Self troubleshooting Connection Manager improvement for USB
  • Improved RF USB Interface
  • Improve order in download queue
  • Improve tests for sort order of Comobjects and Channels
  • Project Details: Add a hover effect for the sub-page headers that are navigation buttons (Details, Security, History, Attachments)
  • Online Catalog Server: Include a Request Header Field to Identify the ETS Version
  • Sending Group address using "Write Value" to Monitor is not displaying correct value in Monitor
  • Show technical details of IoT telegrams in the sidebar only
  • TCP only remote connection
  • Align interface configuration with disabled IA edit
  • Monitor: Add Building Functions and Building Part to the Sidebar Properties
  • Use of the Culture instead of the UiCulture in all input fields
  • Reverse the position of the ‘-' and '+’ buttons when adding rows
  • Password strength indicator
  • Move the "Diagnostics" Toolbar next to the Download button
  • New option "Create default topology" when creating a new project
  • Re-enable the default workspace saving button
  • Check that all ETS object types are copied correctly in the selection order
  • Link With dialog: Allow to confirm selected Group Address with 'Enter' key
  • Improve Group Object Detail View columns ("Linked with" and "Other Linked Groups" columns)
  • Linked folder improvements
  • IoT Point API implementation updates
  • Monitor conditions: Add "contains" and "does not contain" operators for string properties
  • Set Project counters while import
  • Show IA of used interface during download
  • Display available cloud connections in Monitor connection menu
  • Streamline loading of knx_master.xml in Falcon
  • TransferParametersAndFlags in ETS6 significantly slower than in ETS5
  • Persist assigned IP address after download
  • Automatic use of Interfaces not discoverable via Multicast
  • Update MT/ETS to KIM 1.3.8
  • Add a column "ModuleInstance" to the Parameters and Object Lists
  • Add Microsoft.Extensions.DependencyInjection.Abstractions.dll to setup

Bug fixes

User Interface & Functionality

  • RF Multi Device in Ready Mode cannot be downloaded via RF Multi Interface
  • Submodules are hidden in the Parameters dialog
  • Entering a time parameter value out of parameter type range does not show user feedback
  • Download through 2 Media Couplers to RF Segment does not work
  • ETS takes a long time to start after pressing "Skip Login" with a specific Archive
  • Out of memory exception
  • Group address import issue when importing same file twice
  • Delete button does not work when try to delete tunneling interface
  • Wrong warning when compressing an open project twice
  • No close button in exported dialog when exporting several projects and click on skip all
  • Replace Device not working correctly with Modular Application Programs
  • Project Export: The default project export shall be “knxproj”
  • Successive connections to multiple devices via RF USB interface fail
  • Ready coupler is being downloaded as multi link (fast on slot 0) in the TX tables of multi devices
  • Trade- Paste option is not enable
  • Sidebar IP tab--Does not show selected IP address options correctly for IP router/IP interface
  • Group address: Unable to rename Group Address name
  • Backbone Key is not listed in Security report
  • Segments in security domain over backbone not correctly determined
  • The text in the dialog for the connection selection overlaps
  • Keyboard up/down arrows are not working while changing Group Address
  • Ctrl + W keyboard shortcut is closing the window
  • Toolbar: Cannot add folder for device templates
  • Labels: It is possible to create labels for a line but not for a segment
  • Project Wizard creates additional empty Building part with project name
  • Building Panel: Unsorted numbers in Detail View
  • Devices in the tree view without child elements show an expander
  • Treeview: Unlink is not available for devices in the backbone
  • Find (from find and replace) does not work in the treeview
  • Hawk waits only 5 seconds for restart when connected via tunneling
  • Unload All via local connection for devices not supporting MasterReset
  • Deleting Individual Address from sidebar is not updating
  • Decimal value in the monitor seems to be wrong (DPT 8.010)
  • DCA tab- Error shown instead of DCA content
  • ETS 6.2.0 freezes with a specific ETS App
  • ETS crashes while linking the group objects
  • Wrong Interface Information Export
  • Bus monitor statistics report incomplete when started from Group Monitor
  • Diagnostic panel: After saving the telegram in xml, panel stops working
  • Monitor: Do not display AdditionalAddresses as "Unknown"
  • Split & Merge: NullRef on merge, when Function is deleted from main project
  • Fails to write Individual Address
  • Wrong Caption in Collapsed Tree View
  • DeviceCompare does not honor CheckLimit (for BCU1)
  • Named Collection Tree Nodes are not expanded when collection receives first element
  • Unable to merge projects
  • "Add rooms" dialog: The numerical control buttons are not shown correctly
  • "X" (Close) is missing when we uninstall ETS app
  • Export group addresses does not register filename changes
  • Show sending Group Address name on Objects on Project and Device Reports
  • Detail view line selection issue
  • Catalog exception: When Deleting the added device
  • Catalog panel: Issue with result
  • Device Info progress bar does not work in Diagnostics panel
  • ETS ignores help topic in manufacturers help file
  • Line scan: Gracefully handle mask versions not in knx_master
  • Second "Download All" of secure device with BCU Key fails
  • When reading TargetPath from Baggage.xml the default value has to be string.empty instead of null