Added MQTT client integration
New
Exosphere: Session & Event Database Connector
- write custom data to a database table defined in Exosphere
- Configure table in Exosphere and add a Table object under Exosphere plugin in Loxone Config
- Configure the data you want to write
- Can be used for Billing, Logging, Monitoring
Added MQTT client integration
- insert MQTT integration under network periphery
- one single connection to the same broker per Miniserver
- 16 subscription inputs, max. 16 publish outputs
- No real time communication
Honeywell Plugin
- seamlessly integrate Honeywell MB-Secure and MB-Secure Pro security systems with the Miniserver
- support for arming and disarming, Detector groups, Macros, Doors
Gardena Smart System integration
- Receive states and control your Gardena smart devices (SILENO mowers, irrigation control, sensors, …)
R20-T372 Dali Broadcast Mode for Dali Extension
BG-T3514: M-Bus enable Primary Address Search
A3D9-T1434: When switching through settings with tab, combo box drop-downs are now opened
- A3D9-T1402: Load Manager Improvements
- New “Peak Load Manager & Overload Protection” which combines peak load management with overload protection
- New Load Shedding Delay Setting
- General Improvements
Logger: Send daily/weekly/monthly logs per email
- File size is limited to 1 MB
A3D9-T1410: Added columns for room and installation location to device status dialog
- Installation location column is hidden per default
- Added table settings button to show/hide columns
A3D9-T1408: Grid preselection in project planning now allows to use 1-Phase Meter Tree
A3D9-T1386: The advanced miniserver search now allows to use CIDR representation for ip ranges
A3D9-T1433: New Output “Rest” in Energy Flow Manager
- Shows rest power of the top group
A3D9-T1348 Communication Monitor for AC Control
Removed gentle mode from Valve Actuator Tree
Added support for wave packet control to Dimmer Extension
A3D9-T1391 Improved Auto Configuration
- Presence Simulation is an option you can choose
- Throughfares can have a presence block
- Improved descriptions for options
- Light moods ‘Relaxed Bright’ and ‘Creative’ no longer created
- Button 6 on Touch Nightlight toggles Night Mode and LED Status represents if Night mode active
- Water alarm does not call Fire Brigade
- Panic Alarm has Touches of Sleeping Room connected
- Air Devices used in Emergency Alarm automatically set to On/Off button behaviour
- Power Supply & Backup function block created even when not yet fully configured
- Adapted default values for Presence Sensors (volume (250 / 1000) and Presence Duration without movement (1800s))
- Air Devices which get connected to Long Click function block are automatically set to On/Off button behaviour
- Automatic Shades which don’t have yet a proper Dir parameter does not lock the app and can be still controlled
- Audio Master/Client get a configuration dialog when inserted
A3D9-T1403 Meters Calculate Power from Meter Reading when no power is connected
Touch Pure Flex Gen.2
Valve Actuator Gen.2
AC for LG
NFC Code Touch: added support for variable length tags with OCPP
A3D9-T1491: Cloud Services now get Miniserver serial, version and update-level when Miniserver requests data, for better staging/production possibilities
Fixed
General
- BG-I32214 configure device button in network device learning dialog was in wrong state initially
- BG-I32308 HTTP body gets truncated when https request has no content length (virtual outputs, virtual http inputs)
- BG-I32302 Media Controller didn’t switch to a mode on power-on when there was never a mode set before (first use)
- BG-I29112 NFC Authentication auth via App not working with Two-Factor
- BG-I32232 Text Generator Connecting Uid outputs of Wallbox and NFC Authentication did not automatically connect to Uid input
- LiveView activates when Miniserver state changes
- BG-I32067 Custom Object-Permissions get lost when copy/pasting controls
- BG-I32296 Connecting multiple actors at once does not work via Connection-Window
- BG-I32411 Display Echo command on light controller is not as long active as before which breaks custom logic
- Hoermann Air commands not sent to device
- Some Air-Devices can’t be added
- Some diagnosis inputs are visible per default when learning the device via app
- BG-I32108 Internal Api commands visible in Flex Api Generator Dialog
- BG-I29892 NFC Authentication Value not verified in Config for parameter “Bbr”
- BG-I31907 NFC Authentication Wrong tooltip shown for inputs
- BG-I32200 NFC Authentication Connecting input via (+) does not always connect it to a correct input
- BG-I32189 NFC Authentication Dialog wrong output prefix ‘Q’ when output connected to outputs O1-O6
- BG-I31943 Status Monitor no check for invalid characters which could break structure file of app
- No info in caption bar when client Miniservers are not yet ready
- BG-I32101 Sequence Controller spaces get lost when concatenating text elements
- BG-I32012 App-Device-Search Tree of Intercom not shown
- BG-I31917 App-Device-Search missing switchboard-options for extension-search results
- BG-I31918 App-Device-Search Link Devices not replaceable
- BG-I3215 Multiple connections between same connectors possible
- BG-I31980 Presence Control delay activation via Touch Flex to avoid concurrent commands
- BG-I31830 Miniserver Gen.1 does not get an IP address from DHCP when it takes too long to answer (Increased timeouts)
- BG-I32053 Home Button not translatable
- Connection reference can be moved by selecting other objects
- BG-I31930 Insert of Audio devices not always enabled
- BG-I31148 HealthCheck got stuck in endless loop when executing diagnosis on Miniserver Compact with no stereo extensions connected
- BG-I32094 main menu in Project Management view is cutoff on small screen resolutions
- BG-I31910 when loading a project directly from Exosphere cancel didn’t always work as expected
- BG-I31174 reapply active filters when DeviceStatus data is updated
- BG-I32158 improved scrolling in MyProjects view
- Removed info message box when creating a trust
- Remanence of Analog memory not active per default
- No changes warning when trying to save to Miniserver and there are changes for a Trust
- BG-I31938 Statistics sent to app contain a duplicate entry on month change
- Text Inputs can’t be set via post webservice
- Touch Pure Flex LiveView cannot properly display ° sign
- BG-I31936 Config Tooltip shows device as offline when it just has come back online
- BG-I31982 T5 causes a new edge when closing view after controlling it via LiveView
- BG-I31979 State Text condition not working when a text is set
- BG-I31852 Renaming Intercom Gen.1 with a number does not work
- Spread up send of statistics mail among Miniservers so that not all send at the same time
- BG-I31957 Connecting with dns.loxonecloud.com/{serial} as address throws an error
- BG-I20837 Internorm analogue sensor shown as if correction is active in LiveView
- BG-I31936 Config Tooltip shows device as offline when it just has come back online
- BG-I32342: Home Connect added logging for rate limiting errors
- Fire- / Wateralarm has statistics setting
- BG-I32414: Device Status set default focus to search bar
- Door and Window Monitor invalid text at output Txu
- Logging properties not shown when control has a referenced device
- BG-I32084: Windows & Status Monitor Wrong states when references from client were used
- BG-I32484: Touch Pure Flex brightness is disabled as soon as actor is used in visualization
- Presence detection tracker entry not clear enough when started by app
- Missing texts for new inputs of Window and Window Central
- HTTP Query parameters do not work over WebSocket, causing logout of app
- BG-I32840: Project Validation Statistic entries not used in calculation when connected to Gen.2 Miniservers
- BG-I32735 prevent insertion of TAB characters in System Scheme
- BG-I32991: slow config performance when rebuilding connection flags
- BG-I32805: Password quality check in Loxone Config shows green if the username appears in password
- BG-I32455: Wallbox Manager no target power on Wallbox, if Wallbox and Wallbox Manager on different clients
- Valve Tree does not update its hardware version when it’s learned in by entering the serial manually
- FTP server fails to start on Miniserver Gen.2 when certificate setting is invalid
- BG-I32875: Device status shows new icon for old valve actuator
- Exo Database Connector: Allow Api-Actor on client Miniservers
- BG-I32959: Air Sensors maximum button press duration has no effect
- Tree tooltip shows device as offline even when being online
- BG-I32711: Device Status invalid last receive time of air devices when refreshing status
- Device Status Dialog showed devices without online state as online
- BG-I32611: Hunter Douglas Gen.3 not working with alpha
- BG-I32426: Reference name not updated when function block name changed via App
- BG-I32540: Search for Config ID is now possible
- Fixed login for Admin-Interface
- Minutes Impulse not always triggered
- BG-I32651: Analog sensor completely yellow and no selection visible
- BG-I32331: Permissions of app connections get change when editing control in expert mode
- Device status: wrong icon from M-Bus Extension
- Schedule not immediately recalculated when operating mode changes
- BG-I31910: ESC key didn’t cancel loading of project from Exosphere properly
- BG-I28956: BACnet input reference can’t be copied
Lighting
- BG-I32299 Smart TW Dali actor shows not-supported fade rate in settings
- BG-I31870 Daylight Responsive Lighting step size can be larger than defined maximum steps
- BG-I31976 Light-Circuits configured as Switch are handled as analogue for connected Trackers, Loggers, …
- BG-I32485: Invalid description for XAL Luminaire head caption
- BG-I32922: XAL Light Air Invalid IO’s after converting document
- BG-I32411: Lighting Controller add scene name to RINFO-Command
- BG-I32548: Light Controller output 2C not working if Tdc = Mmd
- BG-I30183: DALI single actuator (not group) min dim level does not work as described
Climate
- BG-I32217 AC does not use adapted target temperature when Eh/Ec is active
- Intelligent Room controller doesn’t validate mode set by app based on capabilities
- BG-I32103 Heating and cooling control Calculation of visualization is not correct
- BG-I31770 Blocked Room controllers are not visible in Heating and Cooling Controller after reboot
- BG-I31959 Mode “Fixed Setpoint” reset after saving into Miniserver
- BG-I32073 Heating and Cooling Controller set to Auto via app does not adapt parameter-value
- BG-I31770 Blocked Room controllers are not visible in Heating and Cooling Controller after reboot
- BG-I32103 Heating and cooling control Calculation or visualization is not correct
Shading
Automatic Shading new parameter ‘Rdd’ to enable reference drive for Complete Up ad Complete Down
- Activate this parameter if you have special shades which need a reference drive down to fully close, often the case when the shades have different physical dead times for up and down
Auto jalousie: change of sunshine state recognized with a delay
BG-I32076: Automatic Shading goes back to shading position
BG-I32394: Automatic Shading Motor lock duration (Mld) affects the same direction using Po/Pc
Devices
Wallbox Tree/Air:
- try using the workaround solution to wake up vehicles that have fallen asleep.
- (Air): Wallbox Air not responding when not charging
Touch Air
- Sometimes not sending temperature/humidity
Dimmer Extension
- BG-I32029 Dimmer Extension restarts when there are unconfigured outputs
RGBW Dimmer Air / Tree
- Adapted dimming curve to old behaviour
Touch Pure Air V3
- improved sensitivity (BG-I30552, BG-I29663)
Valve Actuator Gen.2 Air & Tree:
- improved reference drive
- fixed status led patterns
- fixed input button handling on battery powered valve air
AC Control Air
- BG-I31531 & BG-I31561: Toshiba stuck in initialization sequence
M-Bus Extension
- BG-I30294: M-Bus device can’t be found
- BG-I29380: M-Bus extension can’t find specific device
- BG-I28704: M-Bus values are jumping
Valve Actuator Air
- BG-I32439, BG-I32313, BG-I31981: Poor air communication performance
Audio
BG-I32277 Audio channels visible when using stereo group
Off does not lock TTS
BG-I32035 Forward Lock-State to app
BG-I32341 Music Player shows Airplay/Spotifiy settings in Expert Mode when managed by Playergroup
BG-I32340 Send Room Favourite Priority as individual command when changed via Expert Mode
BG-I32162 Audioservers which will not allow pairing shown in search-dialog
BG-I32036: Player Group Fix Setting for handling service by group not disabled when using master-client players
Off Input of player was not correctly handled
Event Playback was truncated in certain configurations
Spotify gets distorted after approx. 4h playback
LineIn gets out of sync over time
Playback after Event was not correct, could show playing but was muted
Migrated to newest library for playback & sync audio
Soundsuit files are not deleted correctly from RAM disk leading to an out-of-memory condition
Radio stations not correctly playing again after paused (SRF-3, maybe others too)
LineIn stop when transit to Bluetooth
Possible Remote Code Execution Vulnerability in the Communication between Miniserver & Audioserver
Handle permanent Input on ‘Off’ for Audio Player, Audio Central, Audio Group fixed
- When On, Playback and events were stopped
- Services like Spotify connect, Airplay and Bluetooth are actively disconnected and disabled
Multiplicator
- BG-I32087 Trust IOs created in inheriting project inserted on wrong parent
- BG-I32086 Can’t permit users to Trust IOs
Diagnostics
- BG-I28670 Internorm Monitor does not display anything when button is pressed
- BG-I31864 Device information contains duplicate data
Gateway
- BG-I31560 Fetch of def.log from client via device status does not always work
Energy
- Spot Price Optimizer may use intervals further in the future instead of earlier ones when the price is the same
- BG-I32278 Wallbox Enable state and target power not correctly sent when managed by Wallbox Manager
- BG-I31135 Wallbox Meter reading input reset when receiving data from device
- BG-I30324 Default name for Total Meter of Power Supply & does not fit Control-name
- BG-I32480: Energy Flow Monitor Config dialog shows invalid items in rare cases
Auto Configuration
- BG-I32204 Humidity and CO2 does not get connected to IRC
- BG-I32381: Table lamp in Shading blocks
- BG-I32380: House in Deep Sleep and Party not creating mode
Trust
- App has no information when user was disabled by Trust source
Security
- Path Traversal in WebSocket allows access for authenticated users to system files
Stability
BG-I32365 Config crash when searching for AC
BG-I32041 Miniserver starts emergency program after a freshly formatted SD card
BG-I32150 Miniserver has a watchdog reboot when flushing statistics (e.g. at midnight)
BG-I32168 Config crash when creating Undo
BG-I32173 Config crash after changing room
Config crash when setting a serial which is already used
BG-I31939 Config crash when window control is connected to IRC
Config crash when setting a serial which is already used
BG-I31939 Config crash when window control is connected to IRC
BG-I32154 Config crash when changing IRC template
BG-I32445: Safety reboot when Hint-Text contains %-characters
BG-I32193: Miniserver watchdog reboot while statistics are fetched
BG-I32733 fixed possible crash when opening System Schematic dialog
BG-I32634: Config crash when starting update
Send of statistics mail is now further spread to improve stability of send
- Mail will be sent between 00:00 and 03:00 depending on Miniserver serial number
BG-I32704: Miniserver reboot when alarm clock gets unlocked
BG-I32549: crash when received data of HTTP input too large