Added MQTT client integration
New
Exosphere: Session and Event Database Connector
- write custom data to a database table defined in Exosphere
- Configure table in Exosphere and add a Table object under Exosphere plugin in Loxone Config
- Configure the data you want to write
- Can be used for Billing, Logging, Monitoring
Added MQTT client integration
- insert MQTT integration under network periphery
- one single connection to the same broker per Miniserver
- 16 subscription inputs, max. 16 publish outputs
- No real time communication
Honeywell Plugin
- seamlessly integrate Honeywell MB-Secure and MB-Secure Pro security systems with the Miniserver
- support for arming and disarming, Detector groups, Macros, Doors
Gardena Smart System integration
- Receive states and control your Gardena smart devices (SILENO mowers, irrigation control, sensors, …)
R20-T372 Dali Broadcast Mode for Dali Extension
BG-T3514: M-Bus enable Primary Address Search
A3D9-T1434: When switching through settings with tab, combo box drop-downs are now opened
- A3D9-T1402: Load Manager Improvements
- New “Peak Load Manager & Overload Protection” which combines peak load management with overload protection
- New Load Shedding Delay Setting
- General Improvements
Logger: Send daily/weekly/monthly logs per email
- File size is limited to 1 MB
A3D9-T1410: Added columns for room and installation location to device status dialog
- Installation location column is hidden per default
- Added table settings button to show/hide columns
A3D9-T1408: Grid preselection in project planning now allows to use 1-Phase Meter Tree
A3D9-T1386: The advanced miniserver search now allows to use CIDR representation for ip ranges
A3D9-T1433: New Output “Rest” in Energy Flow Manager
- Shows rest power of the top group
A3D9-T1348 Communication Monitor for AC Control
Removed gentle mode from Valve Actuator Tree
Added support for wave packet control to Dimmer Extension
A3D9-T1391 Improved Auto Configuration
- Presence Simulation is an option you can choose
- Throughfares can have a presence block
- Improved descriptions for options
- Light moods ‘Relaxed Bright’ and ‘Creative’ no longer created
- Button 6 on Touch Nightlight toggles Night Mode and LED Status represents if Night mode active
- Water alarm does not call Fire Brigade
- Panic Alarm has Touches of Sleeping Room connected
- Air Devices used in Emergency Alarm automatically set to On/Off button behaviour
- Power Supply & Backup function block created even when not yet fully configured
- Adapted default values for Presence Sensors (volume (250 / 1000) and Presence Duration without movement (1800s))
- Air Devices which get connected to Long Click function block are automatically set to On/Off button behaviour
- Automatic Shades which don’t have yet a proper Dir parameter does not lock the app and can be still controlled
- Audio Master/Client get a configuration dialog when inserted
A3D9-T1403 Meters Calculate Power from Meter Reading when no power is connected
Touch Pure Flex Gen.2
Valve Actuator Gen.2
AC for LG
NFC Code Touch: added support for variable length tags with OCPP
A3D9-T1491: Cloud Services now get Miniserver serial, version and update-level when Miniserver requests data, for better staging/production possibilities
Fixed
General
- BG-I32214 configure device button in network device learning dialog was in wrong state initially
- BG-I32308 HTTP body gets truncated when https request has no content length (virtual outputs, virtual http inputs)
- BG-I32302 Media Controller didn’t switch to a mode on power-on when there was never a mode set before (first use)
- BG-I29112 NFC Authentication auth via App not working with Two-Factor
- BG-I32232 Text Generator Connecting Uid outputs of Wallbox and NFC Authentication did not automatically connect to Uid input
- LiveView activates when Miniserver state changes
- BG-I32067 Custom Object-Permissions get lost when copy/pasting controls
- BG-I32296 Connecting multiple actors at once does not work via Connection-Window
- BG-I32411 Display Echo command on light controller is not as long active as before which breaks custom logic
- Hoermann Air commands not sent to device
- Some Air-Devices can’t be added
- Some diagnosis inputs are visible per default when learning the device via app
- BG-I32108 Internal Api commands visible in Flex Api Generator Dialog
- BG-I29892 NFC Authentication Value not verified in Config for parameter “Bbr”
- BG-I31907 NFC Authentication Wrong tooltip shown for inputs
- BG-I32200 NFC Authentication Connecting input via (+) does not always connect it to a correct input
- BG-I32189 NFC Authentication Dialog wrong output prefix ‘Q’ when output connected to outputs O1-O6
- BG-I31943 Status Monitor no check for invalid characters which could break structure file of app
- No info in caption bar when client Miniservers are not yet ready
- BG-I32101 Sequence Controller spaces get lost when concatenating text elements
- BG-I32012 App-Device-Search Tree of Intercom not shown
- BG-I31917 App-Device-Search missing switchboard-options for extension-search results
- BG-I31918 App-Device-Search Link Devices not replaceable
- BG-I3215 Multiple connections between same connectors possible
- BG-I31980 Presence Control delay activation via Touch Flex to avoid concurrent commands
- BG-I31830 Miniserver Gen.1 does not get an IP address from DHCP when it takes too long to answer (Increased timeouts)
- BG-I32053 Home Button not translatable
- Connection reference can be moved by selecting other objects
- BG-I31930 Insert of Audio devices not always enabled
- BG-I31148 HealthCheck got stuck in endless loop when executing diagnosis on Miniserver Compact with no stereo extensions connected
- BG-I32094 main menu in Project Management view is cutoff on small screen resolutions
- BG-I31910 when loading a project directly from Exosphere cancel didn’t always work as expected
- BG-I31174 reapply active filters when DeviceStatus data is updated
- BG-I32158 improved scrolling in MyProjects view
- Removed info message box when creating a trust
- Remanence of Analog memory not active per default
- No changes warning when trying to save to Miniserver and there are changes for a Trust
- BG-I31938 Statistics sent to app contain a duplicate entry on month change
- Text Inputs can’t be set via post webservice
- Touch Pure Flex LiveView cannot properly display ° sign
- BG-I31936 Config Tooltip shows device as offline when it just has come back online
- BG-I31982 T5 causes a new edge when closing view after controlling it via LiveView
- BG-I31979 State Text condition not working when a text is set
- BG-I31852 Renaming Intercom Gen.1 with a number does not work
- Spread up send of statistics mail among Miniservers so that not all send at the same time
- BG-I31957 Connecting with dns.loxonecloud.com/{serial} as address throws an error
- BG-I20837 Internorm analogue sensor shown as if correction is active in LiveView
- BG-I31936 Config Tooltip shows device as offline when it just has come back online
- BG-I32342: Home Connect added logging for rate limiting errors
- Fire- / Wateralarm has statistics setting
- BG-I32414: Device Status set default focus to search bar
- Door and Window Monitor invalid text at output Txu
- Logging properties not shown when control has a referenced device
- BG-I32084: Windows & Status Monitor Wrong states when references from client were used
- BG-I32484: Touch Pure Flex brightness is disabled as soon as actor is used in visualization
- Presence detection tracker entry not clear enough when started by app
- Missing texts for new inputs of Window and Window Central
- HTTP Query parameters do not work over WebSocket, causing logout of app
- BG-I32840: Project Validation Statistic entries not used in calculation when connected to Gen.2 Miniservers
- BG-I32735 prevent insertion of TAB characters in System Scheme
- BG-I32991: slow config performance when rebuilding connection flags
- BG-I32805: Password quality check in Loxone Config shows green if the username appears in password
- BG-I32455: Wallbox Manager no target power on Wallbox, if Wallbox and Wallbox Manager on different clients
- Valve Tree does not update its hardware version when it’s learned in by entering the serial manually
- FTP server fails to start on Miniserver Gen.2 when certificate setting is invalid
- BG-I32875: Device status shows new icon for old valve actuator
- Exo Database Connector: Allow Api-Actor on client Miniservers
- BG-I32959: Air Sensors maximum button press duration has no effect
- Tree tooltip shows device as offline even when being online
- BG-I32711: Device Status invalid last receive time of air devices when refreshing status
- Device Status Dialog showed devices without online state as online
- BG-I32611: Hunter Douglas Gen.3 not working with alpha
- BG-I32426: Reference name not updated when function block name changed via App
- BG-I32540: Search for Config ID is now possible
- Fixed login for Admin-Interface
- Minutes Impulse not always triggered
- BG-I32651: Analog sensor completely yellow and no selection visible
- BG-I32331: Permissions of app connections get change when editing control in expert mode
- Device status: wrong icon from M-Bus Extension
- Schedule not immediately recalculated when operating mode changes
- BG-I31910: ESC key didn’t cancel loading of project from Exosphere properly
- BG-I28956: BACnet input reference can’t be copied
Lighting
- BG-I32299 Smart TW Dali actor shows not-supported fade rate in settings
- BG-I31870 Daylight Responsive Lighting step size can be larger than defined maximum steps
- BG-I31976 Light-Circuits configured as Switch are handled as analogue for connected Trackers, Loggers, …
- BG-I32485: Invalid description for XAL Luminaire head caption
- BG-I32922: XAL Light Air Invalid IO’s after converting document
- BG-I32411: Lighting Controller add scene name to RINFO-Command
- BG-I32548: Light Controller output 2C not working if Tdc = Mmd
- BG-I30183: DALI single actuator (not group) min dim level does not work as described
Climate
- BG-I32217 AC does not use adapted target temperature when Eh/Ec is active
- Intelligent Room controller doesn’t validate mode set by app based on capabilities
- BG-I32103 Heating and cooling control Calculation of visualization is not correct
- BG-I31770 Blocked Room controllers are not visible in Heating and Cooling Controller after reboot
- BG-I31959 Mode “Fixed Setpoint” reset after saving into Miniserver
- BG-I32073 Heating and Cooling Controller set to Auto via app does not adapt parameter-value
- BG-I31770 Blocked Room controllers are not visible in Heating and Cooling Controller after reboot
- BG-I32103 Heating and cooling control Calculation or visualization is not correct
Shading
Automatic Shading new parameter ‘Rdd’ to enable reference drive for Complete Up ad Complete Down
- Activate this parameter if you have special shades which need a reference drive down to fully close, often the case when the shades have different physical dead times for up and down
Auto jalousie: change of sunshine state recognized with a delay
BG-I32076: Automatic Shading goes back to shading position
BG-I32394: Automatic Shading Motor lock duration (Mld) affects the same direction using Po/Pc
Audio
- BG-I32277 Audio channels visible when using stereo group
- Off does not lock TTS
- BG-I32035 Forward Lock-State to app
- BG-I32341 Music Player shows Airplay/Spotifiy settings in Expert Mode when managed by Playergroup
- BG-I32340 Send Room Favourite Priority as individual command when changed via Expert Mode
- BG-I32162 Audioservers which will not allow pairing shown in search-dialog
- BG-I32036: Player Group Fix Setting for handling service by group not disabled when using master-client players
- Off Input of player was not correctly handled
- Event Playback was truncated in certain configurations
- Spotify gets distorted after approx. 4h playback
- LineIn gets out of sync over time
- Playback after Event was not correct, could show playing but was muted
- Migrated to newest library for playback & sync audio
- Soundsuit files are not deleted correctly from RAM disk leading to an out-of-memory condition
- Radio stations not correctly playing again after paused (SRF-3, maybe others too)
- LineIn stop when transit to Bluetooth
- Possible Remote Code Execution Vulnerability in the Communication between Miniserver & Audioserver
- Handle permanent Input on ‘Off’ for Audio Player, Audio Central, Audio Group fixed
Multiplicator
- BG-I32087 Trust IOs created in inheriting project inserted on wrong parent
- BG-I32086 Can’t permit users to Trust IOs
Diagnostics
- BG-I28670 Internorm Monitor does not display anything when button is pressed
- BG-I31864 Device information contains duplicate data
Gateway
- BG-I31560 Fetch of def.log from client via device status does not always work
Energy
- Spot Price Optimizer may use intervals further in the future instead of earlier ones when the price is the same
- BG-I32278 Wallbox Enable state and target power not correctly sent when managed by Wallbox Manager
- BG-I31135 Wallbox Meter reading input reset when receiving data from device
- BG-I30324 Default name for Total Meter of Power Supply & does not fit Control-name
- BG-I32480: Energy Flow Monitor Config dialog shows invalid items in rare cases
Auto Configuration
- BG-I32204 Humidity and CO2 does not get connected to IRC
- BG-I32381: Table lamp in Shading blocks
- BG-I32380: House in Deep Sleep and Party not creating mode
Trust
- App has no information when user was disabled by Trust source
Security
- Path Traversal in WebSocket allows access for authenticated users to system files
Stability
- BG-I32365 Config crash when searching for AC
- BG-I32041 Miniserver starts emergency program after a freshly formatted SD card
- BG-I32150 Miniserver has a watchdog reboot when flushing statistics (e.g. at midnight)
- BG-I32168 Config crash when creating Undo
- BG-I32173 Config crash after changing room
- Config crash when setting a serial which is already used
- BG-I31939 Config crash when window control is connected to IRC
- Config crash when setting a serial which is already used
- BG-I31939 Config crash when window control is connected to IRC
- BG-I32154 Config crash when changing IRC template
- BG-I32445: Safety reboot when Hint-Text contains %-characters
- BG-I32193: Miniserver watchdog reboot while statistics are fetched
- BG-I32733 fixed possible crash when opening System Schematic dialog
- BG-I32634: Config crash when starting update
- Send of statistics mail is now further spread to improve stability of send
- BG-I32704: Miniserver reboot when alarm clock gets unlocked
- BG-I32549: crash when received data of HTTP input too large