Project management view, certificates, Epex, and more.
Improvements
- New Project Management view with new Message Centre
- Spot Price Optimizer:
- Added Epex Spot integration
- Select Epex Spot as mode to get the current spot prices via the Loxone cloud
- All european Epex markets supported
- Enter a formula to calculate your actual price (e.g. apply surcharge on the spot price)
- BG-I22429 Miniserver Search: Added clear button
- Code Signing Certificate
- Improved Performance of Miniserver when loading program
- Project Planning: Added Hörmann Air
- Energy Flow Monitor: Spot Price Optimizer can be source for price import & export
Bug fixes
General
- BG-I23060 AT holidays contain ‘Good Friday’
- BG-I23014 Usermanagement-Dialog: Columns cant be resized
- BG-I23048 Intercom configure in Config not working when intercom is on client
- BG-I23070 App Air Learning: Learning not properly restarted when it was stopped by a second app
- BG-I21835 Nano Dimmer: doesn’t respect button behaviour set in config
- BG-I22597 forwarding from within user authentication edit dialog to 1-Wire learning dialog didn’t work
- BG-I22211 fixed incorrect parsing of HttpVirtualIn URL when path contains colon character
- BG-I22201 RS232/RS485 learning dialogs did only show extensions of the first found miniserver
- Version on cover page not updating
- BG-I22659 Wrong page selected after aborting connection referencing
- BG-I22202 RS485/RS232 Sensors and actors don’t have the fitting icon
- BG-I22026 Tree selection: When an item is selected the tree is only scroll so far that the item is visible but not its parent
- BG-I22692 Generic View: Empty filter not working
- BG-I22729 Miniserver search: Identify not stopped when closing dialog
- Threshold switch has statistic option
- Application signed with SHA1 signature switched to SHA256
- BG-I22731 Update/Backup Dialog: No information to what document the dialog belongs
- BG-I22549 Autoconnect Shading-Api-Actors to invalid shading type
- BG-I22316 Automatic designer: empty page created when loading from miniserver
- BG-I22577 Automatic designer dialog: show info when no supported controls
- BG-I22596 User: Enable/disable time in config displayed in UTC
- BG-I22566 Sequence control dialog: example sequence saved pressing OK without changes
- BG-I22228 Modbus Server: Sensors are still polled after being deleted
- Wallbox: Charge-session not ended when disconnected during load-shedding / limitation below min-value
- BG-I22656 Statistics with interval are not activated with expert mode
- BG-I22676 Deleting user connected with config doesn’t logoff from config
- Invalid Size for Name-Options-Dialog
- Simulation/Live View use default unit if not defined by control
- BG-I22715 Sequence Control Dialog: if in set string value causes indentation
- BG-I22894 Disabled user not logged off fast enough (check now done each minute instead once an hour)
- BG-I22879 Peripherie tree scrolling with keyboard not possible
- BG-I22710 Power Supply & Backup: Internal connections get lost when doing a cut & paste
- BG-I22871 Modbus TCP: receive buffer not processed completely
- BG-I22636 Modbus TCP: automatically reconnect with permanent receive-errors
- BG-I22847 Modbus TCP: Actors with repetition-interval are sent before remanence is ready
- BG-I22575 Automatic Designer Dialog: invalid style for Date-Picker
- BG-I22576 Scene not shown as locked in app
- BG-I22226 Connection to hidden error output of input reference goes to the top left corner
- BG-I21835 Nano Dimmer: doesn’t respect button behaviour set in config
- Hungarian texts missing
- BG-I23116 Device Status: Rooms String not uniform because of missing space
- BG-I23112 Configure Volume-Threshold-dialog: current values are zeroed after closing dialog
- BG-I23137 Rename of intercom with a number not working
- BG-I22749 Wrong active page after undo
- BG-I22750 Position of controls after undo/redo not always correct
- BG-I22821 Invalid pages after search & replace
- BG-I22670 Value of Weather inputs cant be edited in LiveView
- BG-I22917 Auto configuration: Thresholdtriggers of Wind and frost protection have no remanence
- BG-I22915 Tree selection:
- Scrolling with keys makes unwanted jumps
- Showing of parent objects which was added with BG-I22026 not properly working anymore
- Poolcontroller: Safety shutdown system message does not have a confirm action
- BG-I23252 Usermanagement: Remove of access code not forwarded to clients or trust members
- BG-I23153 Remote Air: Button 3&4 switched in simulation
- BG-I23204 Exported Statistic CSV Time empty when 00:00
- BG-I23214 No error message when starting air search on dummy tree to air bridge
- BG-I22956 RS485 & RS232 extensions show test command button in ribbon
- BG-I23212 Authentication NFC Code Touch has different room than device
- BG-I23128 Invalid selection after object was deleted from tree
- BG-I23099 UDP Monitor does not display sent data
- BG-I22427 IR Actors/Sensor dont have a room or category setting
- BG-I23223 API actors of devices missing
- Unable to load from Miniserver which was updated from an old version
- BG-I23308 LiveView not possible during backup
- BG-I23261 Rooms/Controls of Clients disappear in the visualisation when the usergroup of a user which is has full access rights gets updated (e.g. from trust update)
- BG-I23452 Auto Configuration: Power Supply & Backup is created with connection reference
- A07R-I403 Hörmann Air invalid unit for opening/closing setting
- BG-I23476 Power Supply & Backup: Automatic positioning not correct
- Project not set to modified when adding user to user group via drag and drop
- Modbus TCP: Invalid values not discarded when received length less than expected
- BG-I22777 Adding more than 16 NFC Tag in Config causes visible names of Tags above project title
- BG-I23046 Bbr input of the NFC block is multiplied by 10
- BG-I22600 Access controller block information assign device is visible despite device is assigned
- BG-I23215 Access Code NFC: Time schedule gets lost after reactivation of code
- BG-I23255 BG-I23199 VIN HTTP cmd learning window did not show content when server replied with chunked transfer encoding
- BG-I22040 VIN HTTP cmd learning didn’t consider content encodings other than UTF-8
- BG-I23271 Gate: Unlock from Central block lifts active lock on individual gate
- BG-I23329 Add support for analog/digital values connected to text-inputs of control
- BG-I23313 Fixed simulation crash when starting invalid sequence
- BG-I22995 Empty Error-Output for some invalid set commands
- BG-I23382 Icons missing after auto update
- BG-I23319 Adapted text of identification button for devices which do an audible and a visual identification
- Prevent access to system by setting invalid configuration settings via webservice
- BG-I23288 Temperature shutdown input can’t be set via LiveView or webservice
- BG-I22722 Connection to error output displays a unit
- BG-I23398 Not all Monitors docked when opening with device webservice
- BG-I23421 Text in Dali search not translatable
- Serial ‘Auto’ handling improved
- Auto is now displayed in serial setting
- First ‘Auto’ Air Device is learned (previously only dummy device was learned)
- Handling is now always done if there are ‘Auto’ devices (previously only when Extension was also on ‘Auto’)
- Fixed handling of tree with different branches
- BG-I23369 PI Controller: Prevent sample in one of the first cycles where inputs are not yet loaded
- BG-I23503 VIN HTTP learn dialog doesn’t work when url contains certain delimiters
- BG-I23499 missing customer address in ‘My projects’ view
- BG-I23508 right after adding Multi Extension Air, 1-Wire devices couldn’t be learned in correctly
- BG-I23507 1-wire search now stays active instead of being automatically stopped after last search result
- BG-I23570 update buttons for older versions were displayed in ‘My projects’ view
- BG-I23538 VIN HTTP learning dialog highlighting was incorrect if the boundaries of the found pattern spanned multiple lines
- BG-I23571 project management view was closed in some situations (e.g. when removing a project)
- Miniserver when starting the action via the Multi Edit row
- Document not modified when replacing Extension
- No warning prior to the update when the utilisation of the Miniserver is already very high
- Adapted utilisation calculations for gateways
- Generic View (Monitors): New items are shown even if they don’t fit the current active filter
- BG-I23575 Generic View: Copy of password
- BG-I23468 Config-Tree: Systemstatus bubble not emptied after disconnect
- BG-I22485 deprecated “no devices to assign”-message shown
- Presence Control: Place of configured Presence controls not shown in gateway-client-systems
- BG-I23529 Name option dialog: validate strings on opening
- BG-I23448 Central (old) Triple click on Light Controller does not turn off other configured Lightcontrollers
- BG-I23009 Modbusserver: suspend regular communication during test-commands
- BG-I23509 Project not set to modified when changing access schedule
- BG-I22566 Reset sample sequence when creating new tab
- BG-I23374 IO’s of Devices learned in with app visible after miniserver-update via app
- BG-I22807 Sequence Control: enable remanence input
- BG-I23479 Lighting Group: reason for unconfigured control not shown in property window
- BG-I23477 prevent jump to device-page when deleting reference on page
- BG-I23500 Tree Search: Red Circle start Search on all Branches.
- BG-I23474 Cancelled drag-operation of Actor leaves “referenced” state
Devices & Extensions
- new binary for Touch Flex Air: fixed timekeeping issues
- new binary for Roomsensor Air V2: fixed timekeeping issues
- BG-I18960 LED stripes are flashing after power on reset from RGBW Dimmer Tree
- new firmware for valve tree: improved position stability
Lighting
- BG-I22584 Lightcontroller-Dialog: allow id’s between 1 and 90 for all inputs
Energy
- Wallbox: prioritise Enable-Input over app-commands when disconnecting
- Spot Price Optimizer: Improved use of current value when inputs are not updated often enough
- Spot Price Optimizer: Output not activating often enough when inputting decimal hours
- BG-T3005 No proper information when meter objects have nothing connected to their inputs
- BG-I22474 Energy Flow Monitor: Deleting or cutting a control removes it from the Energy Flow Monitor
- Energy Flow Monitor:
- Added statistic of yield so that app can display proper values
- A3D9-T930 Calculation of delivery reading in group node returns 0
- Meter shown as unconfigured when only meter reading is connected
- Wallbox: Separate info for app if power or meter reading is used
- Spot price optimizer: Auto connect of inputs not working when plus sign is the first character
- BG-I22977 Wallbox Tree/Air: Different default Modbus settings than extension
- BG-I23171 Wallbox does not recognize changes on LM5 during charging
- BG-I23175 Wallbox: charging restarted after pausing via app
- BG-I23042 Energy Flow Monitor: Optimised structure when all meters of a Power Supply & Backup are in one group
- The group will be shown added as distribution board to the LoxApp
- This minimises the amount of needed requests for the app
- BG-I23246 Meter does not use actual input reading for total meter reading
- Previously the difference was constantly added, resulting in problems when invalid values were on the input side (e.g. wrong reading via Modbus)
- a negative offset was also not possible because of this
- Now when the meter is non accumulating the offseted input meter reading will be directly set to the output
- Day/Month/Year will continue to be calculated differentially!
- Meter Reading which jumps between an invalid 0 value and the actual value always adds to day/week/month/..
- BG-I23337 Meter for storage: Discharge/Charge output and input naming incorrect (switched)
- BG-I22672 Wallbox: prevent decimal-input for parameter Muv
- Spot Price Optimizer not shown as unconfigured
Shading
- BG-I22489 Autojalouse has Unnecessary device setting
- BG-I22548 Autojalousie: Connecting API connector to As while having relays makes invalid connection
- BG-I22945 Central Shading: column “Description” shows no values
- BG-I23044 Automatic Shading: active Automatic stopped or restarted with SPS/Sunshine when Automatic position is 100%
Client-Gateway
- BG-I22462 Color Favourites not forwarded in client gateway systems
- Increased Client Task watchdog timeouts
- Tree on Intercom not working when there are multiple intercoms on different Miniservers in a Client/Gateway
Trust
- Trust user groups cant be added when users were transferred from another Member before
- BG-I22308 Trust: Identical user names from different trust clients cannot be distinguished in history of NFC Code Touch
- Trust data handling not thread safe
- Trust: Usergroup is immediately deleted when source member removes it unintentionally
- Trust invalid nfc appid/key used when data was inherited from one member
- Trust member online state not hidden per default
- BG-I23049 Trusted intercom is reported as offline when doing an update
- BG-I23418 Trust: Permissions of renamed user not updated on client
- BG-I23418 Trust: Deleting a user and immediately creating it again with the same name may lead to problems
Multiplicator
- BG-I22969 Multiplicator: Endless reboot due to deviating Dali address settings
- Multiplicator: Load from Miniserver not loading program after an update
- BG-I23185 Multiplicator: Collapse button in periphery tree not working
- Devices show status in settings
- Inheriting project can be converted to Multiplicator project
- Managed Miniservers are hidden by filter
- Onboarding: Added more information
- Opening of Touch Pure Flex dialog directly deinherits device
- Editing of transferred devices/pages not possible as long as serial is not entered
- BG-I23481 Config crash in periphery tree
- Ribbon Drop Down: Items not updated and show empty brackets, when no serial is set
- Minimum column width for status column
- Status of Miniserver without working HTTPs connection cant be fetched
- BG-I23343 Miniserver connect and save button list empty
- Connection not shown when loading from Miniserver
- BG-I23354 Multiplicator: Project shown as modified
- Error message when saving to Miniserver after changes where reset
- Miniserver reboot when loading program from Miniserver
- BG-I23514 Devices which were created via app not reintegrated into multiplicator file
- Todo message always appear when one was added by local changes
- BG-I23501 Replace in Miniserver search not consistent to other learn dialogs (name is taken over)
- Not reachable Miniserver with red background
- Temporary devices which are created while learning devices are added as change
- Manage Miniservers dialog: Even when row is filtered save/update/backup is done to that
- Icon missing in ‘My Projects’ view
- Improved sizing of columns in dialog
- BG-I23493 Warning that Miniserver needs an update even if its not reachable and no version is set
- Added ‘Load Changes from all Miniservers’ button
- Deviation dialog: Added/Deleted controls have now coloured cell
- Message popups have placeholder icon
- Search: Replace does not take over name
- Invalid version is displayed as an error (now only version will be shown orange)
- Undo does not always readd Miniserver in management dialog
- Columns not resizable after add of a new Miniserver
- Not all deviations properly displayed as setting
- Opening Web Interface does not open web interface of selected managed Miniserver
Project Planning
- BG-I22586 Project Planning does not create Power Supply & Backup
- BG-I22649 Partlist generation shows dimmer extension 110V
- BG-I22619 Selection ‘None’ not available for presence detection and touch devices
- BG-I22960 Speaker planned when using a different default plan than the german one
- BG-I23058 Speaker with concrete backbox generates backbox for suspended ceiling
- BG-I23249 Generated excel file contains fixed values instead of formulas
- BG-I23012 Project Planning does not create dali devices
- BG-I23286 Lighting devices in wrong power group
- BG-I23043 Planning tool: Power Supply and Backup wrong calculated in the PartList preview
Sequence Controller
- BG-I23320 Fixed rounding bug when comparing IO-Values to hard coded numbers
- BG-I23265 Right term in IF doesn’t accept a variable in division
- BG-I23266 Fixed renaming variables during active simulation
- BG-I23377 Power x^n is not formatted correctly
- BG-I23459 Automatically add end sequence after pasting text
Stability
- Config crash during startup
- Miniserver reboot due to race condition in trust handling
- BG-I22973 Config crash on drag and drop
- BG-I22942 Config crash in statistics dialog
- BG-I22830 Possible Config crash when resetting all Multiplicator deviations
- BG-I22829 Config crash while creating connection reference
- BG-I22892 Config crash while calibrating valve devices
- BG-I22834 Config crash during air search
- Possible Miniserver safety reboot causes
- BG-I23108 Config crash when editing nfc code validity in dialog
- Config crash during startup
- BG-I23124 Config crash in diagnosis dialog
- BG-I23301 Config crash when closing sequence controller dialog directly after editing something
- BG-I23168 Config crash in pages window
- BG-I23114 Modulo with number smaller than 1 causes config crash
- Miniserver reboot when NFC requests unknown credentials
- BG-I23237 Config crash when loading from Miniserver
- BG-I23180 Config crash in permission management dialog when browsing to group/user
- BG-I23307 Config crash when connecting 2 NFC code touches to block
- BG-I23342 Config crash after deleting audioserver
- BG-I23530 Config-Crash when searching for controls during liveview
- BG-I23470 Music Player Group fix: Config crash when deleting all pages containing assigned players