Setting icon for objects in periphery tree is now displayed
Improvements
- A3D9-T1347: Ac Unit Controller: Added History
- DALI Extension: DALI2 support for DALI Extension with HW Id 4
- A3D9-T1344: Support for Sending Error Codes to Backend
- A3D9-T1339: Support for Reporting Wallbox Model properly
- A3D9-T1338: Support for Reporting Serial number and Firmware Version
- A3D9-T1337: Support for Remote Start/Stop Transactions
- A3D9-T1371 Setting icon for objects in periphery tree is now displayed instead of normal icon for better accessibility
- Added Wever & Ducré Light Tree
- A3D9-T1388: Audio Volume Fading
- A3D9-T1250: Garage/Gate Central: Added “Partially Open” Input
- A3D9-T1336: Audioplayer: Added Bluetooth pairing output
- A3D9-T1335: Parameters can now be added as a Combo Box
- A3D9-T1335: Changed Parameters to Combo boxes in some blocks
- BG-I30796 NFC Code Touch Block: Deleting all entries is now possible
- BG-I30795 NFC Code Touch Block: CSV Template now uses the time formats of system locale
- A3D9-T1393: Message Center: showing recent messages with thumbnails and added possibility to delete messages
- A3D9-I10: Audio Diagnosis performs basic network checks and serial verification for offline Audioservers
Bug fixes
General
- Cloud Services are reported as inactive when request fails
- Auto connect to Miniserver does not use addresses from project
- BG-I31336 Virtual HTTP input can’t be fetched in config when using only a username and no password
- Settings of Alarm Siren Tamper input not correctly set for new devices
- Import of User can’t parse NFC tag when it contains quotes
- Connection to Miniserver fails and no message is generated
- Analog Sensor not directly displayed as offline anymore after a Miniserver restart
- RC Key view dialog setting suggests editing
- Miele token timeouts resulting in a re-login
- NFC Codes stop working when updating from an older version
- BG-I31023 OCPP Wrong formatting in Description of server address setting
- BG-I30924: Fixed Config crash when creating Belimo Devices
- BG-I25014: Missing/invalid entries in Belimo Monitor
- BG-I31367 Gusts of weather service not working on client/gateway
- BG-I31350 Add of Miniserver to a Gateway does not preselect an external address
- BG-I27375 RS485 call command
- BG-I25234 RS485 does not receive more than 512 characters
- Row in Generic View (e.g. Miniserver search) shown as selected but not actually selected
- BG-I31297 Periphery tree jumps when editing an item
- BG-I31339 All Plugin actors (e.g. Home Connect) are set on a reboot instead of only the used ones
- BG-I30868: Expert Mode: Users with direct access to control can’t select all available rooms
- BG-I31149: Permission Dialog shows wrong data after changing room of control
- BG-I30896: Automatic-Designer conditions for NFC-text outputs only triggered once
- BG-I30928: Energy Meter Tree: Add sensor-information to tree monitor
- BG-I31025 Virtual Input stayed red after changing Min/Max
- BG-I31142 Central Controls: ‘Off’ in combination with DisPc permanently blocks configured controls
- BG-I31196 Invalid or missing options for AC Unit Controller in automatic designer
- BG-I31144 Equal block ON because of rounding error
- BG-I30969 Too long control commands to a client may file (e.g. editing schedule block which is on a client)
- Older version can’t be installed over newer version of Loxone Config
- BG-I20283 Online status not monitored system message gets shown
- BG-I30784 Monoflop getting stuck on On
- BG-I30815 New documents don’t have country set, resulting in wrong preselected air channels
- BG-I31100 Selection gets lost, when pasting multiple controls
- BG-I31036 fixed slightly mismatching font-size between App and Config in system schematic
- BG-I30976 ensuring that HTML entities are encoded to Unicode for display in MessageCenter
- BG-I31037 System Schematics: fixed handling for moving of items and scrolling of view by keyboard
- BG-I30382 Login with Loxone account in Config wasn’t possible if username/password contained ‘+’ sign
- A3D9-T1331 Improved some bugs with the auto positioning
- BG-I30786 Window Block not closing if Weather Protection input is on and miniserver restarts
- BG-I30854 Fetch of backup file list from devices fails occasionally
- Connection to Miniserver cant be established sometimes when connecting out of keychain
- Invalid Jsons when values are invalid
- Cloud Mailer continues to send emails despite quota already reached
- BG-I26940: Detailed Device Information for some AIR devices is not working
- CloudDNS request is now done with HTTPS and in a more general manner
- BG-I31630: Gate Controller has wrong options for type
- BG-I31631: IRC is shown as unconfigured in project analysis when only AC Controllers are connected
- BG-I31632: AC Central Controller is shown as an error in project analysis
- BG-I31586: Automatic Designer: missing translations for Heating and Cooling Controller
- BG-I31471: App Search tree: keep search results after automatic end of search
- Miniserver configuration dialog shows wrong current address, when connected externally
- BG-I31345: Certain values can’t be set via expert mode on some settings
- BG-I31507: IR sensors can’t be controlled via LiveView
- BG-I31346: System schematic has a visualization password setting
- BG-I31523: NFC Tag not exporting when exporting users (only first tag will be exported)
- Single click on text ‘Edit…’ in property window does not open the edit dialog
- BG-I31399: Hörmann Air: Invalid visibility of travel duration parameters
- BG-I31595: Config locks up when dragging a constant to a parameter
- BG-I31599: Connecting from Miniserver Keychain does not use project data when internal and external address is empty
- BG-I31375: Message Center view was incorrectly hiding some messages in some situations
- Certificate fetch on Miniserver Gen.1 not retried fast enough
- BG-I31658: Update of internal Audioserver on Miniserver Compact fails
- BG-I31400: Normal Config search can’t find objects with diacritics
- BG-I31667: ‘Delay after start’ setting is not used on Burglar alarm, when before the reboot a sensor was active
- BG-I31757: Io names not displayed depending if the category or room is set
- BG-I31761: Miniserver Replace does not properly create a backup anymore
- BG-I25252: New-Device-Bubble in Gateway documents shows wrong or no data
- User management dialog does not have a proper title
- Tooltip in Tree does not always show a text when colour of item is not green
- Selection in User management dialog jumps when a Username gets edited
- Users and Groups in User management dialog not properly sorted
- Dialog does not open centred on the screen
- Connection reference shown as active, when connected to API output
- Error message when saving to Miniserver
- BG-I31707: MIN/MAX Commands not handled in Sequence Controller
- BG-I31460: Miniserver search dialog showed encrypted Exo credentials, instead of asking user for master password for decryption
- BG-I31483: items in system scheme view couldn’t be aligned properly after changing the scale of the image
- Fixed data loss in interprocessor communication for Miniserver Go Gen2, Miniserver Compact, Miniserver Gen2
- BG-I31615: Intercommunication learn dialog didn’t update count column on package reception
Lighting
- BG-I30183: DALI single actuator (not group) min dim level does not work as described
- BG-I29018: DALI 8 fade rate jump not working with daylight control
- BG-I28842: Dali lamp -> Online in the periphery tree Offline in the device status
- BG-I28606: Device Status Dali Devices shown as offline
- BG-I27520: Periphery Tree Dali Device shown with red dot
- BG-I25345: Human Centric Lighting Dali DT8 parameter Ft causes last manual change to get stuck
- BG-I25237: Dali offline device replace function
- BG-I30304: DALI groups not working on firmware 15.0.3.25
- BG-I29042: Dali Air does not send all commands
- BG-I31569: Light controller displays no states after disconnecting output
- Fixed Miniserver crash when DALI Broadcast Actor is used
- Fixed DALI Min/Max brightness settings for Smart Actuators
Planning
- BG-I31275 Wrong Master/Client count calculated
- BG-I31055 Energy Meter type for Wallbox Meter incorrect
- BG-I31191 Power usage of extensions does not match datasheets
- BG-I31251 Stereo Extension has a colour setting
Stability
- BG-I31377 Auto Save of project may interrupt opened dialogs
- BG-I31477 Config crash when opening Backup/Update dialog
- BG-I31391 Config crash
- Config crash when loading Touch Pure Flex configuration
- BG-I31360 Config crash when opening project
- Config crash when connecting to Miniserver via search
- Config crash when loading from Multiplicator Miniserver
- BG-I31099 Miniserver reboot when Dali group actor changes
- BG-I31056 Config crash when opening Multiplicator file with a deleted climate block
- BG-I29486: Increased stability of Loxone Config when saving large project files
- BG-I31626: Config crash when opening project
- BG-I31705: Miniserver reboot when receiving text memory changes from another Miniserver
- BG-I31228: Watchdog Reset while creating Backup via /dev/sys/createbackup
Climate
- AC Unit Controller Silent Mode overrides manual timer
- AC Unit Controller timer not properly remanent
- BG-I31459 Weatherserver does not have data anymore of previous hours (needed for weather data with absolute hour set)
- Learning per default disabled on IRC but room presets overwrite that preset
- BG-I31019 Flow Temperature Calculator not having a hysteresis for calculation with buffer temperature
- BG-I31223 Ac Control: do not cancel timers when ending silent mode
- BG-I31057 Fixed race condition in copying IRC data
- BG-I31198 Intelligent Room controller: allowed Range for Input ϑExc not documented
- BG-I31170 Mixing Valve Controller: improved description of Error-Output
- AC Unit controller now has a settings-state for the app, which enables the app to faster display the settings page
- AC Unit Controller: Silent Mode not working when set to Off and AC is controlled by IRC
- Text in IRC dialog cut off
- IRC is blinking when dragging an AC Control Air onto the page
- BG-I31312: Remove cyclic mode message to device
- BG-I31266: AC Control does not update IRC-Data after lock
- BG-I31369: Hvac controller triggers prepare phase without excess heating/cooling
- Intelligent Room controller: invalid target temperature when using excess heating/cooling in eco mode + Fahrenheit
- Intelligent Room controller: Single comfort temperature not always converted to Fahrenheit
- BG-I31581: Shown weather in the app starts at the start of the day instead of current time
- BG-I31398: Fixed incorrect translation in Mode-dropdowns for Heating/Cooling Controller and AC Central
- BG-I31686: Old weather entry is shown in the app
- BG-I31381: Invalid Device type for AC Control Toshiba in device information response
- BG-I31751: Heating & Cooling Controller / HVAC controller does not calculate average temperature when locked
- BG-I31771: Intelligent Room Controller: expensive source used even if prioritized less
- BG-I31628: AC Central Controller is wrongfully shown as cause in AC/IRC History
- BG-I31719: AC Unit Controller: change on parameter not immediately applied
Shading
- BG-I30203: Invalid calculated position when using Nano2Relay
- BG-I31123: Automatic Shading: Missing history-elements when calculating shading period
- BG-I31378: Parameters don’t disappear anymore when shading type is changed
Devices
- Gentle Mode for Valve Tree only active if user hasn’t manually increased force
- R20-T287 Dimmer Extension: Refactoring for better ZX Detection and more stable with ripple control signals
- Relaxed Extension update error system message
- Dimmer Extension adapted dim curve to older version
Audio
- Miniserver Compact Audio is shown as offline after a reboot
- Compact Audio not shown as rebooting directly after a restart
- BG-I31060 Setting “Automatic highpass-filter” not shown on Audioplayer when connecting Audioserver-Stereo-Output
- BG-I31101 Wrong resolved address of Audioserver sent to the App resulting in slow connection process
- BG-I31587: Permanent OFF of Audio Central not properly forwarded to Music Player
- Music Player Group + Central Music: Volume command sent when saving into Miniserver
Diagnostics
- Modbus Monitor shows device ID 0 when server is offline
- Select per default the Tree view in the Health Check
- BG-I31048: No proper error message when air route could not be queried from Miniserver
Gateway
- Client shown as offline even if its back online again
- BG-I31610: Can’t add client to gateway, when https is not working or disabled
- BG-I31560: File fetch (e.g. def.log) from a client is rather slow
Energy
- BG-I31007 Spot Price Optimizer Cv Output is now rounded at 3 decimal places
- The buffer target temperature offset ‘B’ now will be used as hysteresis
- If the actual buffer temperature rises above the buffer target temperature (AQf + B) the pump (Qp) will be activated
- If it falls below the target flow temperature (AQf) the pump will be deactivated again
- BG-I30937 Wallbox2 Mr output not incremented after Energy Meter Tree wasn’t used anymore and only Cp Input is connected
- BG-I30929 Energy Manager Output not being correctly displayed as Analog/Digital if Priorities are changed
- BG-I30989 Load Manager Settings are not updated when operating mode is changed
- BG-I31394: Wallbox Off input does not reset Cac output
- BG-I31652: Wallbox2 standby consumption included in next charge
OCPP
- BG-I31193: OCPP Charging Session not resumed when charging allowed output of Wallbox was off
- BG-I31473: OCPP EV Connection Timeout did not disable charging allowed on Wallbox
- BG-I31472: OCPP local billing would get lost after “remote stop” was used
- BG-I31197: OCPP Rejected authorization from OCPP when starting charging via App displayed wrong, local billing lost
- OCPP connection to unsecure OCPP backend via ws:// not possible
- OCPP Charging point would not connect if Wallbox function block had no Tree devices connected
- OCPP Charging point would not pass Selfcheck in some cases
- OCPP Suspended EV/EVSE not sent
- OCPP Authentication after Miniserver reboot caused multiple authentication requests
- OCPP Charging Point not displayed as dummy device in some cases
- BG-I31535: OCPP Chargepoint API Connector does not automatically connect to Wallbox and Authentication NFC Code Touch function block
- OCPP Meter values: Timestamp of meter value was sent instead of current timestamp which caused problems on OCPP backend
- OCPP Reset: Charging station model and serial number not properly sent after soft and hard reset
- OCPP Changing TxUpdateInterval not possible and changes not persistent
- OCPP Transactions not restarted after power outage in rare cases
Multiplicator
- Client Miniserver can be added
- BG-I31039 Trust search does not work externally
- BG-I31745: Config crash when editing intercommunication setting
Trust
- BG-I31752: When trying to takeover users from Trust Manager, always Manager takeover is preselected
BACnet
- BG-I31382: Miniserver does not respond to requests on the devices BACnet port
Auto Configuration
- Undo not properly saved before doing Auto Configuration
Home Connect
- BG-I31527: Oven can’t be added when it does not support the preheating program
- Slowed down requests when having a lot of devices, to prevent rate limiting by API
Project Planning
- BG-I30973 Master/Client not having a need for power
- Plugin has high memory usage
- NCF Authentication: new authorization request sent when another authentication is in progress
- not all states sent to Plugin after reboot