Update

Trust Members can now be sorted and grouped together for a better overview in the periphery tree

Improvements

Trust

  • Trust Members can now be sorted and grouped together for a better overview in the periphery tree
  • Assign Usermanagement right automatically to members
  • Trust Link: Switch to other Trust Members where you user has permissions for the visualisation easily within the app without any need to reauthenticate

Health Check (Menu > Diagnostics > Health Check)

  • The Health Check integrates the diagnostic tools of Link, Tree and Air into a unified user interface.
  • It allows for a comprehensive review during and at the end of a project,
  • ensuring that the wiring and other critical aspects meet the standard.

A3D9-T1066 Added Control History for Auto Jalousie, Light Controller and Intelligent Roomcontroller

A3D9-T1062 Climate Controller add output for average outdoor temperature

Export Users to CSV

A3D9-T1055 Modbus High Performance Input

  • reduce common minimum polling-cycle to 1s (except Air-Devices)
  • up to 2 Sensors per Modbus-Server or Extension allow a minimum time of 0.1s
  • if multiple modbus-servers with same IP (TCP) or multiple devices with same Device-ID(TCP + RTU) exists, performance sensors are disabled for these devices

Intercommunication: Added support for Smart Actuator values

Memory Flag: Added support for Smart Actuator values

Spot Price optimizer: Added CZ market (uses OTE as source)

A3D9-T1034 added setting for automatic deletion of statistics

  • Enabled per default for new controls

Added new Config HTTP client (e.g. used for connection to Miniserver)BG-I23356 Control Linking dialogs: Show device name to better distinguish IOs

A3D9-T991 New outputs for Meters: add new outputs for meters for last day/month/year

A3D9-T947 NFC Tag Diagnostic Tool add new tool for reading and formatting nfc tag

A3D9-T888 New Mode for ClimateController (OFF = -1) (Needs new app version)

BACnet:

  • Invalid properties (time, date, utc offset)
  • Adapted Model name
  • Adapted vendor name
  • Added support for device reinitialization command
  • Added support for foreign device properties
  • Removed unsupported IPv6 mode

Ping: Added support for statistics

A3D9-T1059 Add new interval for statistics 15 min

A3D9-T948 Templates can be downloaded and inserted via Quicksearch now

A3D9-T1073: Add last day/month/year outputs for wallbox

Fixed

General

  • Config transfers update file for wrong type to Miniserver
  • BG-I25574 User object has phone attribute twice in xml
  • BG-I25576 Kosovo can’t be selected as country
  • BG-I23749 System Status: Webservices in client/gateway systems return an error
  • BG-I25544 SPS not restarting after saving to the Miniserver
  • Pages of gateway project are not sorted alphabetically anymore
  • BG-I25488 Presence Sensor MaxTime between Motion not working anymore
  • BG-I25311 Touch&Grill: wrong naming for Inputs of Room 2
  • BG-I25371 Automatic renaming of device + referenced control does not work when appending numbers
  • Device Status Dialog: title not translatable
  • BG-I25499 Periphery Tree: Cabinet not displayed for network devices (e.g. Audioserver)
  • BG-I25514 Edit all Extensions only lists extensions of gateway
  • BG-I25421 Selection Switch (+/-): Entered Parameters not validated
  • BG-I25428 Page window: Uses different sorting than page tabs and program tree
  • BG-I25391 Touch Flex: Controls from other Miniservers are displayed in selection dialog
  • BG-I25084 Drag and Drop of multiple API actors not working
  • BG-I25478 Miniserver Replace/Convert: Onboard Digital Inputs/Outputs and Analog Inputs are not replaced by an equivalent Extension
  • BG-I25519 EFM dialog: Selection after removing a meter
  • BG-I24995 Combobox shows wrong items when opening drop down
  • BG-I25405 Miniserver allows invalid subnet mask
  • BG-I15045 NFC Code Touch: deactivated user name not showing in history
  • BG-I17819 NFC Code Touch Air: “access denied” message after firmware update
  • BG-I22661 Fixed drawing error in Lightcontroller-dialog
  • BG-I24685 Control Drawing: show part of additional connector-text if there is room
  • BG-I24377 Options Dialog: editing first selected item does not work
  • BG-I25455 Central (Old) moving blinds not stopped with Cu/Cd
  • BG-I25380 Miniserver Gen.1 can’t download web interface when its too big
  • Monitor: Empty device combobox shown
  • Settings icon for first item in periphery tree was hidden behind collapse icon
  • BG-I25275 search dialogs of plugins display the provided name for each search result
  • BG-I25425 Creating room via API creates a different room on a client
  • BG-I25424 Special characters not correctly converted by http client
  • BG-I25324 Belimo sensors not listed in reference selection dropdown
  • Plugin IO: Invalid unit after creation
  • BG-I25263 Control Preset: Select current preset when opening manage dialog
  • BG-I25395 Nano Motor Controller: There is no systemmessage when an overcurrent is detected
  • BG-I25405 Config allows invalid subnet mask
  • BG-I25480 Quick Search shows wrong top result in languages with diacritics
  • BG-I25284 Project Planning: Creation of config file fails when there are power supplies in rooms
  • BG-I25398 User Import/Export: Added custom fields
  • BG-I25435 SD Format dialog: Version combobox not shown in some cases
  • BG-I25411 Miniserver reboot when learning Hörmann Air via App
  • BG-I24938 added Ctrl-O shortcut to project management view
  • BG-I24828 corrected click behaviour of menu items in project management view
  • BG-I24587 initial filtering in monitors only worked correctly on empty views
  • BG-I24866 HTTP VOut Off-Cmd did not send POST request when body data was set empty
  • BG-I25086 Sauna target temperature not saved when changed via API Command
  • Load from Miniserver with custom external address does not use HTTP connection
  • BG-I24840 Deactivated automatic rule is executed
  • BG-I24591 Intercom Search: results without valid serial number shown
  • BG-I24496 Nano 2 Relay: Api-Connector not working on Roof Window Shading
  • BG-I24781 Roof Window Shading: Automatic not restarted with daychange
  • Roof Window Shading: change of Sunshine-State not immediately recognized
  • AcControl Txe-irq is disabled after last byte in Tx-buffer
  • BG-I25168 Learning dialog: Automatic device selection not always working
  • BG-I25273 Function blocks show a unit in their description
  • BG-I25304 SD Format: Allow version select for Miniserver Compacts
  • SD Format Dialog: Version combobox not updated when downloaded firmware packages are modified
  • BG-I25136 Program Tree: Multi Selection does not properly select items
  • BG-I25270 Invalid selection after paste
  • BG-I25342 Touch Pure Flex control selections get lost after adding project to a gateway
  • BG-I24953 Periphery tree filter gets removed after inserting something
  • BG-I25150 Resetting password does not work properly, if there’s a user ‘admin’ without permissions
  • BG-I25254 Touch Pure Flex configuration is not automatically loaded when learned via app
  • BG-I25277 No error message when Loxone Config fails to load the icon library
  • BG-I25281 Tree to Air Bridge Room not displayed and gets lost after saving project to Miniserver
  • BG-I25218 No info on how to proceed after changing gateway
  • BG-I24622 Drag and Drop of multiple system variables not always working
  • BG-I24695 LoxoneFormat not starting when there is already a instance open
  • BG-I25356 Statistic dialog: Difficult to fetch very old statistics added ‘until’ date selection
  • Air Base encryption key changes after first save to Miniserver
  • BG-I25292 Pool Controller: Delay is not considered when pump was started due to a temperature control cycle
  • BG-I24280 Sequence Controller does not get started with start pulse
  • BG-I24511 Room filter does not expand stereo childs
  • BG-I25854 New user does not receive all states via websocket
  • BG-I25203 HTTP Request with Basic authentication with User only
  • BG-T3187 Nano Motor Controller: Increased maximum for current settings to 5000 mA
  • BG-I25857 No proper return code when client does not respond to app command
  • BG-I25764 Alarm Clock: Tna output does not update after midnight
  • BG-I25814 AC Control: API Get Value commands not working
  • BG-I25791 Device Update available message gets triggered constantly
  • BG-I25856 Wrong object type and icon for user caption
  • BG-I25808 Problems when correction is set to all same values
  • BG-I25823 Miniserver always sends a ‘Content-Type’ HTTP header for http requests (e.g. Http input) even if there is no body
  • BG-I25781 Hide references that should be hidden (conversion of invalid documents)
  • BG-I25896 Virtual HTTP input has invalid polling time
  • BG-I25889 Automatic scrolling in view does not stop
  • 1-Wire DS2438 does not get a proper name when created from search
  • BG-I25758 Home Connect: Devices of type ‘oven’ don’t have an actor to start the current selected program
  • NFC Tag which is also learned on a disabled user is not directly skipped
  • UDP Monitor: Sent intercommunication packet shown as received
  • NFC Credentials generated when first needed, instead of at document creation. Fixes duplicate credentials when using default document as basis
  • BG-I25750 Sequence Controller: Active sleep not aborted when changing mode
  • BG-I25749 Audioserver: send Miniserver-Timezone on init
  • BG-I25722 No error message when setting same encryption key on a second Air Base
  • BG-I25743 Modbus Monitor shows invalid text when an error is received
  • BG-I25697 Generic Table: Paste of text value with comma on numeric edit not working
  • BG-I24702 1-Wire Extension: Detailed device information is missing 1-Wire statistics
  • BG-I25620 Caption Bar displays that no project is opened even if one is open
  • BG-I25681 Tree and Air devices: Panel not displayed in periphery tree
  • BG-I25696 HTTP Input: Onlinestate input missing when inserting template
  • Permitted Users dialog: Added Multiedit line
  • BG-I25489 Generic Table: Non editable cell is emptied
  • BG-I23749 System Status: Webservices in client/gateway systems return an error
  • BG-I25652 Automatic file name stops at 99 (“Untitled 99.Loxone”)
  • BG-I25691 Runtime Counter: Maintenance Interval defined by logic not properly handled
  • BG-I25627 User is immediately deleted when expiration action is set to delete and user is not yet in the enabled timespan
  • BG-I25602 Text Generator: Trust-Userid not recognized
  • BG-I25427 Air/Treedevices/Music Zones have no api-actor after conversion
  • BG-I25572 Operating Mode: sensor creates an edge after restart
  • BG-I25559 Text generator: autoconnect of userid to supported controls
  • BG-I24804 Device Status: no battery value for Internorm Devices
  • Device update abort after only one try. “Update failed” message will show up after five tries have been unsuccessful
  • QU1-I356 Devicestatus: increased timeout for audioserver/intercom diagnosis
  • BG-I25847 Intelligent Roomcontroller: adapt Heat/Frost Protection temperatures when comfort-temperature is above/below
  • BG-I25617 Textgenerator: output is not empty when using unconfigured properties
  • BG-I25703 Belimo Air/Tree: invalid object type in context menu
  • BG-I25752 AC Control: disconnect API-connector keeps entries disabled
  • Loading of Custom changes from Miniserver fails (resulting in invalid or lost data)
  • Loading is now done via HTTP which is more reliable
  • No error message when loading of custom changes from Miniserver fails
  • BG-I25931 Periphery tree sorting not correct after insert of Miniserver Compact
  • BG-I25834 Miniserver Gen.1: Detection if SD card is broken not reliable
  • BG-I25711 Monitor: Device filter not working for all technologies
  • Monitor stops when changing device filter
  • BG-I24245 Extension learning: Modbus Extension cant be replaced
  • Manually editing serial number in extension learning dialog may show ‘Duplicate serial’ error
  • BG-I25930 Periphery Tree: Objects disappear after renaming one directly on the page
  • BG-I25857 Return client name when web service fails
  • Miniserver: Improved startup speed during loading of permission infos
  • HomeKit Plugin does not display proper name in property window description
  • Insert of objects is slow
  • BG-I25805 Daytimer-Dialog: Color-Info text cut off
  • AcControl Mel Fanspeeds, DaiS21 Mode Auto, refixed Uart IRQ, communication watchdog time
  • BG-I26017 Miniserver fails to load new configuration after update (Config transferred invalid file)
  • Control History
  • IRC: duplicate entries if climate controller blocks additional output
  • added entry when additional outputs are enabled
  • LiCo: Added entry when mood is edited
  • Adapted RSSI limits for air devices
  • BG-I25694 Ac Control: Airflow, Fanspeed not restored after reboot
  • AC Control: Added Fan Speed “Silent” for standalone controls
  • BG-I26023 Control History: invalid timestamp after web service + additional fixes
  • Trust Link: Peers are shown which have not yet joined
  • Tree diagnosis slow when there are dummy devices
  • BG-I25983 Misleading error message when connection gets lost during saving to Miniserver
  • BG-I25997 Program: Increased length limit for PicoC text output to 4096 bytes (from 1023)
  • BACnet:
  • Remove High/Low Limit property for analog outputs since its not conform with the standard
  • Fixed change of network port properties
  • BG-I25888 Window: Movement by Weather-Protection is not finished
  • Ac-Control: Add mode “Silent” for Mitsubishi Electric

Devices & Extensions

  • New binary (14.03.08.02) for Modbus Air (Fix Watchdog, Offline blinking)
  • New binary (14.03.08.02) for Hörmann Air (Fix Watchdog)
  • New binaries (14.03.08.03) for Wallbox Tree/Air (activated HW-Watchdog; removed Modbus debugging feature)
  • BG-I24056 Nano IO: Change of usage causing no reaction of relays
  • improved performance of access codes in big trust installations
  • new binaries for NFC Code Touch Tree (Gen. 1 and Gen. 2) and NFC Code Touch Air (Gen. 2):
  • improved performance in big trust installations
  • improved NFC performance
  • improved firmware update process
  • new valve tree binary: fixed valves increasing force slightly after saving into miniserver
  • new Touch Pure Flex binary: improved wakeup handling for temperature/humidity measurement
  • BG-I20160 NFC Code Touch: NFC Credentials not random

Energy

  • BG-I25279 Wallbox: new value on limit input changes manual limit
  • Epex Spot: Miniserver thinks data is outdated after day change
  • BG-I25678 Wallbox: manual limit not set when started via app
  • BG-I25593 Energy Manager: User cant decide manually if the load is analog or digital (added a selection box)
  • BG-I25714 Wallbox: charging session-user lost after reboot when connection to input Uid is not remanent
  • Wallbox 7.4kW: invalid default values after drag&drop

Shading

  • BG-I25950 Automatic Shading: Parameter Dts/Dte handled incorrectly for 2nd shading period of north-oriented windows

Belimo

  • BG-I24769 Belimo Addressing: device not assignable
  • BG-I25383 Belimo configuration dialog: cursor position not restored

Audio

  • BG-I25283 Audio Server: Stereo Outputs cannot be separated if Audioserver was a Compact before
  • BG-I24327 Music Zone: UPNP Settings not shown

Lighting

  • BG-I24728 Light Controller: incorrect moods when connecting unconfigured lighting group
  • BG-I25837 Light Controller: Memory flags with Smart Actuator Type not properly detected
  • BG-I25957 Central Light: Unselected Lightcontroller Gen. 1 turned off

Climate

  • BG-I24852 Climate Controller Dialog: Roomcontrollers updated without changes
  • BG-I24943 Climate Controller not turning on with IRC demand
  • BG-I24507 Room Ventilation: percentages shown with three decimal places
  • BG-I25401 Invalid default values for Intelligent Temperature Controller / Heat Curve in Fahrenheit
  • BG-I24896 Mixing Valve Controller: outputs not updated after OFF
  • BG-I24946 Intelligent Room Controller switches rapidly between heating and cooling if temperature is exactly heat protection
  • BG-I24633 Intelligent Roomcontroller: wrong target temperature
  • BG-I25566 Intelligent Roomcontroller: too many debug-outputs while reset is active
  • BG-I25560 Intelligent Roomcontroller: do not cancel timers when
  • BG-I25694 AC-Control: negative edge on Input ‘Off’ does not restore last settings
  • BG-I25611 Ac-Control: Temperature-outputs not restored after reset

Client-Gateway

  • BG-I25193 Gateway/Client: Manual change in Live View does not update IO on page
  • Gateway fails to send command to client since its too long (e.g. update of user group)
  • Gateway/Client: Update of user from trust spams client connection

Trust

  • Trust User Group: Does not contain a user which has been transferred to the local Miniserver
  • BG-I25501 Trust Members are displayed offline when online state input is used in project on a gateway/client system
  • Trust User/Usergroup suddenly a local object
  • All user groups updated when a user is removed from any group
  • Miniserver sends hello to each trust member on each reboot
  • BG-I25789 Trust IO not properly handled when it comes from a Multiplicator Miniserver (duplicated unique IDs were not distinguished)
  • BG-I25663 Trust: changed UserID is not synchronised
  • Allow to view user authentication settings when its a trusted user

Multiplicator

  • BG-I25338 Multiplicator: Temporarily added users will never get removed
  • Conversion to Multiplicator project resets serials of internal devices
  • BG-I25169 Trust update in Multiplicator project fails when connected externally
  • BG-I25861 Connection references not shown when opening base file out of inheriting project
  • BG-I25844 Multiplicator requests timeout and fail when internal address is not reachable
  • BG-I25591 Multiplicator: Closing project also closes all child projects

Project Planning

  • BG-I23871 Changed Bedroom types in UK default file
  • BG-I25583 Audioserver not created anymore
  • BG-I24544 Project Planning: US default file contains additional speakers
  • Project Planning: Exported file for Schrack also exports unsupported products

Auto Configuration

  • BG-I24957 Auto Configuration Dialog: Check/Uncheck via column header always changes all rows including filtered ones

Stability

  • BG-I25354 Config crash when moving object on page
  • BG-I24753 Miniserver reboot when using Intercom Gen.1 and Gen.2 in the same project in a certain order
  • BG-I25277 Config crash when loading icon library
  • BG-I25313 Config crash while device search is active and Miniserver connection gets lost
  • Miniserver reboot when object is deleted by program change
  • BG-I25458 Config crash while using quick search
  • Miniserver reboot when using Belimo devices
  • BG-I25492 Config crash after deleting wallbox
  • BG-I25490 Miniserver reboot when loading custom changes
  • Miniserver reboot caused by access function block
  • Config crash during startup
  • BG-I25811 Config crash when selecting an onlinestate input of an IR module
  • BG-I25658 Miniserver reboot when Trust user group or user gets deleted which was directly permitted to rooms on a client gateway
  • Race Condition in gateway after saving to Miniserver causes a deadlock
  • Miniserver reboot when receiving invalid answer from client
  • BG-I25658 Miniserver reboot when loading custom changes
  • BG-I25754 Miniserver reboot after learning Aquastar Air
  • BG-I25472 Config crash when LiveView button is used in quick access toolbar
  • Miniserver reboot when applying out of range values via parameters
  • BG-I25969 Config crash when loading from Miniserver
  • BG-I25927 Miniserver reboot loop due to missing nfc credentials
Version: 14.4.9.25 Link