Update

This update only contains maintenance work

Resolved Known Issues

  • Audio: The issue of excessive QIO log notifications when switching from primary/backup using the button in QSD has been resolved.
  • Amplifiers: Resolved the issue when adding PL-LA8 or PL-LA12 components to a new design and editing the number of segments, the number of input pins does not increase correspondingly as expected.
  • Video: Improved Dell 5440 compatibility with USB driver errors within Windows Device Manager.
  • Video: Reduced the occurrence of the "offline" message shown when; unplugging and replugging a USB-C laptop video source with a camera video bridge; or soft rebooting the NV21 and Core simultaneously.
  • Video: Reduced the occurrence where the NV-21-HU Decoder goes missing followed by the Encoder while using Shift streams.
  • Video: Addressed an issue where Camera status would report "OK - Camera started"; Camera status now reports "OK".
  • Video: Resolved the issue where, upon redeployment, cameras were resetting to coordinates (0, 0, 0) instead of retaining their privacy position.
  • Video: CEC function on NV-21-HU no longer reports a "Fault - Command not acknowledged" status.
  • Video: Addressed the issue where, during camera privacy mode, IP streams were not blank as expected, and after exiting privacy mode, the live preview remained stuck.
  • Video: Resolved the issue where the HID Conferencing Controller could disrupt USB Bridging functionality on the NV-32-H Encoder.
  • Video: An issue that would cause the error "Fault because Output stream LAN A Streaming Error (Packet Missing)on NV-32-H has been resolved.
  • Video: NV-21-HU devices no longer fails to output video if HPD never goes low or off when HDMI Enable is toggled on or off.
  • Video: Resolved switching AV router performance when rapidly switching no longer causes the Core to become unresponsive.
  • Video: The issue regarding USB device connection failures, previously experienced on NV-32-H devices with Windows Code 43 error, has been resolved.
  • Video: Improved USB connection reliability where NV-21-HU devices would experience USB enumeration failures or show "Valid Format" detection failures.
  • Video: Control within Q-SYS Designer no longer becomes sluggish when running scripts with NV-32-H devices.
  • Video: Resolved an issue where NV-32-H Decoder encounters an error “Fault- Not Receiving video from <encoder name="">”.
  • Control: Resolved an issue where TSC-G2 touch panels enter a reboot loop and would not negotiate on 100Mbps.
  • Control: Resolved the issue where attempting to delete the Monitoring Proxy status component, added in Q-SYS Designer v9.10.0 and then opened in v9.9.0, resulted in an error "Error updating Monitoring Proxy".
  • Control: An issue that caused rendered text and other controls to appear blurry in HTML-based UCIs only has been resolved.
  • Control: Resolved the issue where customers experiencing unexpected core failovers, C++ exceptions with scriptable controls, and premature deletion of Timers in Lua scripting.
  • Platform: Resolved an issue where the Core Status block will report a “Compromised - System performance utilization has hit a critical value”.
  • Platform: Resolved the issue where Q-SYS Media Stream Receivers in v9.10.0 were unable to accept streams from Visionary Solutions network video encoders.
  • Platform: Resolved the issue where Q-SYS Cores were sending factory-default hostnames instead of user-specified ones to DHCP servers.
  • Management: Renaming a Q-SYS device no longer results in both original and new names appearing in Configurator.</encoder>