Bug Fixes
- This hotfix addresses the following anomalies:
- In Designer release 4.7.35, whenever the Coverage Map of a live 920 is displayed, the lobe placements are incorrect when Auto Coverage is Off. All the lobes are “stacked” on each other.
- Meanwhile, the web UI for the 920 in this scenario is correct, as well as the Designer 4.7.35 SDC for the 920. It’s only the Designer 4.7 Coverage Map that is the issue (and only when Auto Coverage is Off).
- For this issue, in the Designer 4.7 Coverage Map, the x/y/z values for each lobe are correct (even though the visualization is incorrect). However, if a user tries to manually overwrite the x/y/z positions, they will still take effect, but the visualization in the Coverage Map will not change.
- For this issue, in the Designer 4.7 Coverage Map, if the user clicks and drags a lobe, the change will take effect on the actual 920, and the updated position will be shown correctly in Designer (but only for the lobes that have been manually clicked and dragged).
Pre-Upgrade Requirements
- Multiple versions of Designer cannot be installed on the same computer
- Designer and SystemOn cannot be installed on the same computer
- Before you upgrade Designer:
- Export project files
- Certain endpoint protection software may block the installation of Designer. If you encounter this issue, whitelist the Designer Installer, or application.
Platform Requirements
- Supported Operating Systems
- Windows 10 and 11 (Professional or Enterprise), 64-bit edition
- Supported Web Browsers
- Chrome
- Safari
- Windows Edge
- Minimum Hardware Requirements
- 8 GB RAM (16 GB may be required when hundreds of devices are being accessed)
- 2 GB hard disk
- i5 dual-core processor
Upgrade Path
- Designer versions 3.0 and 3.1 must be upgraded to 3.2 first, before upgrading to this version of Designer. Download Designer 3.2 here.
- If you encounter an Installer failure during upgrade, allow the uninstaller process to finish, then restart installation.
Notes
- To update firmware, please download Shure Update Utility
- Project files and database are not backward compatible with versions prior to 4.5
- Templates saved in earlier versions of Designer are moved to a project named ‘Templates’ beginning in version 4.5.0
- This version of Designer is compatible with the following recommended software and firmware versions:
- IntelliMix Room 4.2.0
- ANIUSB-MATRIX 4.7.23
- MXA310 4.7.8
- MXA710 1.5.16
- MXA910 4.7.13
- MXA920 1.5.24
- MXA902 5.0.115 (please see the FAQ for more information)
- MXA-MUTE 1.5.23
- MXN5-C 1.5.21
- P300 4.7.24