Firmware Update Required for ULXD4D and ULXD4Q Receivers
New Features:
- Nothing known
Enhancements:
- Firmware versions 1.4.8 and 2.0.28 are critical updates before upgrading to newer versions.
- All ULX-D devices should be updated to the same firmware version for compatibility.
Fixed Bugs:
- A false failure may be reported when downgrading to 1.5.6; workaround available by using Shure Update Utility.
Open Issues:
- Group Scan Deployment and Custom Group Load may not function with older ULXD4/ULXD4D/ULXD4Q firmware versions.
Update Instructions:
- Users must update ULXD4D and ULXD4Q receivers with firmware prior to 1.4.8 to version 1.4.8.
- For receivers between versions 1.4.8 and 2.0.28, update to 2.0.28 before proceeding to the latest firmware.
- To update ULXD1/2 transmitters, access the receiver menu:
- <code>DEVICE UTILITIES > TX FW UPDATE</code>,
- Align infrared ports and press <code>ENTER</code>.
- Recommended versions for compatibility include:
- ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers: 2.7.3
- Axient AXT600 Spectrum Manager: 2.1.41
- SBC250/450/850 Networked Charging Stations: 2.7.3
- Shure Update Utility: 2.7.2
- ShurePlus Channels iOS: 1.5.2
- ShurePlus Channels Android: 1.1.1
- Wireless Workbench: 6.15.0