Safety applications IO-Link modules release
Important notes
The ET200AL IO-Link I/O modules are approved for use in safety applications up to SILCL2 or Cat 3/PL d.
The IO-Link I/O modules of the ET200AL are not performing any safety functions, so the safety-oriented tripping of the digital outputs is performed via the shutdown of the load current supply by the higher-level safety relay.
With the DIQ modules, the digital channels are shutting down by switching off the additional power supply of the IO-Link Port Class B, and in the DQ module by switching off the additional power supply of the M12-L power connector.
In the event of safety-oriented tripping, communication with the IO-Link master remains in place, so that a shutdown can be reported as a diagnostic event.
Product information
The following IO-Link modules can be used for safety applications:
- ET 200AL, IO-Link, DIQ 4+DQ 4x 24VDC/0.5A, 8XM8 - 6ES71435BF000BL0
- ET 200AL, IO-Link, DIQ 16x24VDC/0.5A, 8XM12 - 6ES71435AH000BL0
- ET 200AL, IO-Link, DQ 8x 24VDC/2A, 8XM12 - 6ES71425AF000BL0