CFC: Rewiring of connected signals is possible in each case

Release Notes SICDM V05.10

Engineering for SICAM A8000 series:

  • 6MF21010AB100AA0, CP-8000 Master Module with I/O -25/+70 C
  • 6MF21011AB100AA0, CP-8000 Master Module with I/O -40/+70 C
  • 6MF28012AA00, CP-8021 Master Module
  • 6MF28022AA00, CP-8022 Master Module with GPRS
  • 6MF28031AA00, CP-8031 Master Modul
  • 6MF28050AA00, CP-8050 Master Modul
  • 6MF28010AA00, CP-8010 Master Modul
  • 6MF28012AA00, CP-8012 Master Modul with LTE

Engineering of SICAM 8 Software Solution:

  • Linux based industry-PCs

Engineering of Enhanced Grid Sensor

  • Enhanced Grid Sensor (EGS)

Supported operating systems:

  • Microsoft Windows 10
  • Microsoft Windows 11
  • Microsoft Windows 2019 Server
  • Microsoft Windows 2022 Server

New functions:
Device Manager functions:
Device templates and mass rollout

  • Create device template from device
  • Create device from "Device template" incl. signal exchange
  • Create device template for mass rollout

IEC 61850

  • Create IEC 61850 server data model from SCD file (Top-Down-Engineering)
  • Configure mode/behavior hierarchy
  • GOOSE late binding

Improvements

  • SICDM: Redundancy - empty signal nodes are not deleted on B-Device [206639]
  • CFC: When importing ACG (.csv/.xlsx), the import of instance with names including whitespaces is now prevented. A corresponding error message appears in the result file. [199770]
  • CFC: Rewiring of connected signals is possible in each case [205237]
  • SICDM: SICAM Device Manager V5.01 does not start - OPENGL settings [203611]
  • SICDM: Manually configured ENS mapping is retained during IEC 61850 client import [204449]
  • SICDM: Dashboard tiles are wrongly displayed if the RTU Settings are leaved and reopened [204447]
  • CFC: When filtering signals, the DEL (ENTF) key always deletes a character to the right of the cursor [205965]
  • CFC: The comment for global variables is now updated with ACG import (.csv/.xlsx) both on the variable in the TaskCard as well as in the individual charts in the properties of the used variable. [193658]
  • SICDM: Signal import - filters in the error display do not work [206047]
  • SICDM : After updating the redundant devices (devices B), the interface assignments for the protocols are no longer taken over from device A but are used as set in device B. [206763]
  • SICDM: IEC 61850 Server tile does not open for redundant B-devices [202401]
  • SICDM: deactivated license message regarding ALM and FPM [189072]
  • ST: Also non-latin characters may be used in comments in ST-code [202568]
Version: V05.10 Link