Configurable number of reports
SICDM SICAM Device Manager
V05.20, release date: 10.07.2025
New Features
Device Manager functions:
IEC 61850
- Update IEC 61850 server data model from SCD file (Top-Down-Engineering)
- Configurable number of reports
SICAM HMI - Signal parameters in SHMI tile
Device templates - Create remote device configuration data incl. archives with and without applications
Others - Context menu for project overview
- Rebranding SICAM S8000 & SICAM S8000 RTU Apps
- Show SICAM Device Manager release notes incl. history in SICAM Help tab (link in About dialog)
- Support of system extensions for applications (e.g. PODMANEXT)
SICAM 8 Help
- Documents
- SICAM Device Manager
- SICAM Logic Editor
- SICAM 8 Core Functions & Hardware
- SICAM 8 Applications Communication
- SICAM 8 S8000 RTU Automation & Telecontrol Functions
- SICAM 8 Application Visualization & Operation
- SICAM 8 Administrator Security
- Function Point Manager FPM
Compatibilty:
The following combinations of the SICAM Events & Alarms, SICAM HMI, SICAM WEB and SICAM Device Manager applications are compatible:
- SICAM Device Manager V04.40, SWEB00 06.40, SEVA 1.50.0, SHMI 1.50.0
- SICAM Device Manager >=V05.01, SWEB00 >=06.51, SEVA >=2.0.0, SHMI >=2.0.0 (precondition CPCI85 >=06, RTUM85>=06 and SICORE >=2.0.0 for SICAM S8000) [204714]
Logic editor functions:
Sequential Function Chart (SFC)
- Support of SFC Action block: ACTION
Structured text (ST) - Function calls with array arguments
Others - TIA Update v20 [196230]
Improvements
- CFC: performance improvement when using global variables with structures [214120]
- CFC: Help (GER) missing Topic not found [211044]
- SICDM: Signal assignments: Wrong text color in case of column selection [210208]
- CFC: If the module MODIFY_S is not completely connected, compilation will now return correct error messages. [210194]
- SICDM: A more detailed message is shown in case that the assigned SIAPP is not found. [210075]
- CFC: Correction of RETAIN behavior when calling a ST block [209941]
- CFC: correct SFC block checks [209940]
- SICDM: Upload/Download correct text update [208825]
- SICDM: IEC 61850 Server - open reports-tile on a redundant B device causes an UI-exception [208780]
- CFC: For the type test during the consistency check, block inputs are now also considered. [208092]
- SICDM: When deleting signals in the table view, empty nodes are also removed [206648]
- SICDM: Nodes & their contents cannot get expanded in tree view [206615]
- SICDM: Signal table - incorrect filling and incrementing (unassigned entry) [206588]
- SICDM: Error loading due to parameter files being too large [205835]
- SICDM: SCC visualization problem - bulgarian characters [205776]
- SICDM: Recent projects list not complete [205224]
- SICDM: Error when filling down for RTU signals - processing type [194294]