SCD file import function like SICAM PAS (Subset for SICAM)
V26.10, release date: 03.2026
Engineering for SICAM A8000 series:
New Features
Device Manager functions
IEC 61850
- SCD file import function like SICAM PAS (Subset for SICAM)
- Import filter for attributes used in static data sets
CP-8030
- Support of CP-8030 device type (successor CP-8021)
Remote Device Configuration
- Export of RTU parameter
Logging
- Syslog and Event log (UDP Protocol)
Multilanguage Translation Tool
- SICAM WEB support (without diagnosis texts)
SICAM 8 Help Documents
- SICAM Device Manager
- SICAM Logic Editor
- SICAM 8 Core Functions & Hardware
- SICAM 8 Applications Communication
- SICAM 8 S8000 RTU Automation & Telecontrol Functions
- SICAM 8 Application Visualization & Operation
- SICAM 8 Administrator Security
- Function Point Manager FPM
Logic editor functions
CP-8030
- CFC - no retained attribute for certain function blocks and local/global variables
Structures and global library
- Global library update performance improvements
- Structure editor performance improvements
Improvements
Info attributes
- Attribute fields restricts the maximum value to 1000000 for FLOAT and INTEGER types [250131]
- Info attributes are not copied when using device template [233497]
Logic editor
- ACG Import, when validating the sheet bar size, the current page size is now taken into account. [250125]
- During ACG import, cells are now also imported when the text is stored directly in the cell rather than in a shared string. This is especially important for XLSX files that were created from Access. [248967]
- The UFB instance selector combobox has been widened so that longer UFB instance paths can be fully displayed. Users can now select which UFB instance should be used even while offline, when choosing Simulation or Go Online. Users can open a UFB instance directly via the “Open” context menu from within the CFC or UFB editor window. A resource compilation is required to update UFB instance paths if changes have been made. [247251]
- Partitions are now updated properly [233467]
- CFC -partition names are unique after re-import [233039]
- The depth of control structures is now unlimited [233015]
- Structured Text - use of complex expressions in WHILE conditions are supported [232876]
- Data types - positive DINT constants are casted implicitly to DWORD, other constants or connections result in a type mismatch error. [228824]
- Performance of import to global library is improved [226233]
SNMP
- Password does not work when containing special characters (e.g. "<", ">") [249536]
- Type error in SNMP Manager settings [245187]
Signal import
- Error importing signal list from signals2csv created import file (SICAM TOOLBOX II) [246911]
- Import of Info attributes doesn't work correctly [233493]
- Crash when importing a large number of signals and assignments (including a large number of parameter columns, memory overflow) [230578]
- Sporadically fatal error when importing signals and assignments (memory consumption problem) [230577]
Expert mode
- Exception by switching to expert mode and reopen device overview [246642]
IEC 61850
- The existing signal description is retained during the IEC 61850 server update [244014]
- GOOSE late binding error after update of IID-file within System Configurator Tool [233002]
Hardware
- No error message when configuring unsupported HW-module for CP-8021 [233058]
Download
- Downloading problem of CP-8050 configuration (description parameter has more than 256 byte) [226770]