Various improvements and bug fixes
API based configuration
- In addition to the manual configuration of the SIMATIC CC7, a REST based API is now also available, which can be used to automate or script all settings of the SIMATIC CC7 via tools such as cURL, Postman etc.
Access to the configuration of the SIMATIC CC7 via cloud interface.
- The P1 cloud interface can now also optionally be used for reconfiguration of the SIMATIC CC7 via WBM or API.
Arbitrary distribution of the same process value over different topics
- Process values can now also be assigned across different topics and cloud profiles. This simplifies project planning enormously, especially for distributed cloud systems, since double project planning of the data points is no longer necessary.
User-defined payload templates
- User-specific payload templates can be created and stored in the SIMATIC CC7.
- This simplifies the project engineering, if e.g. several topics have to use the same user specific payloads or the format changes regularly.
Additional extensions for IPv6
IPv6 can now also be used at the process data interface e.g. for the connection of IPv6 based process stations.
New filter options in the configuration interface
Data point and topic overviews in the web interface can now be filtered using SQL syntax. This makes it much easier to work with large quantity scaffolds.
Extended import functions for data points
Data imports from S7 data sources can now include nested structures and Array of Structs
Additional feature enhancements / improvements / security fixes:
WBM: 2 active parallel web sessions can be established per user.OPC-UA-Client: Discover functionality now also sets IP address, hostname + path if selected.WBM-User: The previously fixed session timeout of 10min can now be set manually. Possible values are 10min, 30min, 1h, 1day, 1 week.MQTT TLS1.3: Support of the cipher TLS_AES_128_CCM_SHA256.WBM: Overview pages for clear activation / deactivation of profiles and stations added.OPC-UA-Server: Correction of an error that when setting a too small sampling interval after activating the configuration, the sampling interval was set to 5s.S7-Char-DP-Trigger: Correction that the data point trigger can be used correctly for CHAR data points in the range 0-254.OPC-UA-Server ArrayDimensions: Fixed bug that for array datapoints the array dimension was always set to 0.OPC UA Server Certificate: Diagnostic message added if the IP address or DNS name in the certificate of the CloudConnect OPC UA Server does not match the current configuration.RTF: When resetting to factory settings, the diagnostic buffer is now cleared as already described in the manual.DHCP+IPv6 Support P2: The interface P2 has been adapted to the functions of P1 and can now also successfully use an IPv4 and/or an IPv6 address via DHCP or a fixed configuration.Modbus IPv6: Modbus process stations can now also be used via an IPv6 address.Modbus: Several Modbus devices with different RTU addresses but the same IP address can be created as stations.