Update

Provides some various enhancements that focuses most on Dante variants

Improvement(s)

? (Dante models only) You can now route analog signals to DZR-D and DXS-XLF-D for output to a Dante network.
* Dante firmware also needs to be updated to 4.1.6.7-4.1.6.5-1.1.0.

✔ ️ Improved operation when disconnecting while transmitting information to an external control device, such as ProVisionaire Control or ProVisionaire Touch.

Resolved Issue(s)

✔ ️ Solved a problem in which the operation of the main knob to remove the panel lock was reflected immediately after the lock was removed, when the PIN code had been saved to a USB flash drive.

✔ ️ Solved a problem in which some current parameters could not be loaded, when the data including AMP PRESET in DEVICE BACKUP> RESTORE FROM USB was loaded (V1.1.1 or later).

✔ ️ (Dante models only) Solved a problem in which the Dante settings seemed to have changed when loading a setting file from a USB flash drive while DANTE SETUP was set to lock or DDM (Dante Domain Manager) was set to READ ONLY.

✔ ️ (Dante models only) Solved a problem in which the Dante Rx label was not set to the default value when the connecting mode to the Dante network using USB flash drive was read from Quick Config to STANDARD mode.

✔ ️ (Dante models only) Solved a problem in which the mixer (CL/QL series) was not notified that the maximum number of connectable external control devices had been reached.

✔ ️ (Dante models only) Solved the problem in which the display was not updated even after updating the IP address, when the IP address is set to DHCP and the DHCP server was started after the local address was operated.

✔ ️ (Dante models only) Solved the following problem when using ProVisionaire Control.

  • The OVER in the > Analog > Meter on the ProVisionaire Control would not light.
  • Dante Input Meter on the ProVisionaire Control would be displayed about 1dB lower than the actual value.

✔ ️ (Dante models only) Solved a problem in which the following settings were not reflected when using ProVisionaire Touch.

  • Exclusive setting of (A1, A2, D1, D2) and POST EQ on the ROUTER screen
  • Some EQ Gain values
  • The Time value of >ALIGNMENT on the ROUTER screen
  • HPF/LPF frequency value on the HOME screen

✔ ️ (Dante models only) Solved some minor errors.

Known issue(s)

? When mounted on the CL/QL series, the version number may not be displayed correctly on the I/O DEVICE screen.

? When the delay time is set to DISTANCE [m, ft], the displayed value may change when the power is turned off and on due to a conversion error with TIME [ms].