Offers fix to the an LCD touch screen functionality issue
Resolved Issue(s)
✔ ️ Fixed a problem with V4.02 or later firmware, in which a combination of specific operations would cause the LCD touch screen(s) to become inoperable and display the following error message "Software exception has been detected. PLEASE RESTART THIS CONSOLE AS SOON AS POSSIBLE.".
Known Issue(s)
? If a CHANNEL without ANALOG GAIN is copied using the CH COPY function, settings for ANALOG GAIN including Phantom Power and so on will unexpectedly be pasted to the destination channel(s).
? When DSP MIRROR MODE1: TWINLANe MIRROR is used, and HY card slot 2 of RPio is set to ROUTING MODE2, output patches of HY card slot 2 are not taken over automatically by a changeover from A (active DSP) to B (standby DSP).
Workarounds:
- Manually Switch the unit B to the active state.
- Set the same patch to unit B.
- Switch unit A back to the active state.
? MIDI NOTE ON/OFF may not be transmitted correctly if the MIDI Note ON is assigned to a User Defined Key and is rapidly pressed several times.
Note(s)
? When updating CS-R5 from V4.00, first update to V4.02 and then update to V4.20. If CS-R5 is updated directly to V4.20, the touch panels will not respond when the update is completed. If this happens, skip the proper shutdown procedure and turn the power switches off and back on again. The console will operate normally once correctly updated to the V4.20.
? When updating CS-R5 or DSP-RX(-EX) from V4.00 or V4.02, the progress bar may stop or an error may prevent the updating process. If this continues for ten minutes or longer, turn the power off and on again, then re-start the firmware update.
? It is not possible to update DSP-RX(-EX) when using DSP Mirroring and the engine is in 'Standby' state. Please set DSP-RX(-EX) to 'Active' state and then proceed with the update.
? The project file saving method has been changed from V1.20.
When loading a project file saved by V1.16 or earlier, the patching of plug-ins may be unintentionally removed. If this happens, manually patch them again.
? When updating the console's firmware from V1.20 or earlier, the progress bar may stop at the 14/18 status, or an error may stop the updating process. If this continues for five minutes or longer, turn the power of the console to off and on, and then retry the firmware update.
? When loading a project file saved by V1.21 and earlier, the RACK Focus status indicator on the SCENE screen may not light even if effect plug-ins or GEQs are the target of Focus Recall. To indicate the Focus status properly, open the SCENE SETUP (FOCUS) pop-up screen once, and then close it. After doing this, save the revised project file to remove this problem in the future.