The manufacturer Loxone has not yet set up its devicebase profile. Content such as updates, compatibilities and support may only be maintained with a delay.
Update

Add a Shortcut to another Miniserver

New

  • Miniserver Shortcut function block
  • Add a Shortcut to another Miniserver within the visualization
  • A3D9-T1036: Status Monitor
  • Keep an eye on your devices, states, and values with our new generic monitoring block
  • Door And Window Monitor:
  • Allow nesting of Door and Window Monitor objects
  • Allow select of gate controller
  • Meter: Detection and prevention in invalid Meter Readings
  • Decreases in the Meter Reading are not allowed anymore
  • Major increases are detected
  • An invalid change is now detected when the single meter change is bigger than the current Meter Reading and bigger than 10000
  • Only if the time difference since the last value change is smaller than 8h
  • User will be informed via System Message
  • System Message can be deactivated
  • Network Devices: Address Resolve Fallback
  • If the Miniserver fails to connect to the defined hostname/address it will try to find the correct address by searching for the device in the network
  • This enables a connection to the device even if the network settings were misconfigured
  • Hostname entered but the device set to a static IP
  • IP entered but the device has gotten a new IP via DHCP
  • Supported on Miniserver Gen.2 for Loxone Network Devices (Audioserver, Intercom)
  • Added Portuguese
  • Loxone Config Instance handling
  • When a config is already running double clicking a project file now will not start an additional instance of Loxone Config
  • NFC Authentication Block: Import NFC Tags and Access Codes from CSV
  • BG-I25937 Scene: Added LineIn action
  • BG-I27642 Burglar Alarm: add support for combined window contact
  • New Miniserver Connect Dialog
  • New Miniserver Keychain Dialog
  • A3D9-T1121 User Import: Import NFC Tags and Access Codes from CSV
  • Hardened security: Webservices need to be authenticated with a token with the proper rights, when a token is used
  • A3D9-T1085 Window: Added output for target position and input for current position (Can be used with Schüco Windows)
  • Matter (0.3.0)
  • various fixes
  • upgraded to Matter 1.2
  • M-Bus Device: Add sequence number property to analogue inputs
  • DALI extension firmware update DALI device types 0-6 support smart actors
  • A3D9-T1035 Automatic Designer: add action “Gate: partially open”

Fixed

General

  • Ac Control: Wrong type text used for gree/sinclair ac control
  • BG-I28029 Admin Interface reachable when configuring via Internet is disabled
  • BG-I27980 Central Shading: Safety-Reason for “Wa” not remanent
  • BG-I27953 Tree-Filter does not compare room/category names
  • BG-I28023 Network Intercommunication: Smart/T5-sensors not received when using encryption
  • BG-I27543 Tuneable white Dali dimmer is not working when the colour temperature is not used
  • Memory Leak when converting document
  • BG-I26050 Device learning dialogs: same device couldn’t be learned out and in again in the same learning session
  • BG-I26046 Saving project to Miniserver while device diagnostics were running left diagnostics in undefined state
  • BG-I28019 room settings (Combobox settings in general) didn’t work as expected in learning dialogs
  • BG-I27690 Devices with a single sub device were merged
  • BG-I27475 Documentation has missing descriptions for IOs
  • BG-I27693 Optical/Audible identify context menu action not disabled when not connected to the Miniserver
  • BG-I27761 Auto Connect to Miniserver does not properly use address settings from project as fallback
  • BG-I27687 Generic View Column filters not showing ampersands
  • BG-I27688 Unable to distinguish Miniserver captions in template insertion dialog
  • BG-I27834 Network device search uses full qualified hostname, this leads to problems when the domain changes
  • BG-I27722 Connection of memory flag gets lost when changing referenced object via settings
  • BG-I26559 External IO/Memory Flags are not sent to other Miniserver when value changes at SPS restart
  • Addon webservice does not check token rights
  • Tokens marked for deletion still work as Bearer Token for some time
  • An Error message is displayed when using multiple virtual UDP inputs with the same port, even if it does not cause any problems
  • BG-I27702 Ac Control Air Dialog: prevent unselecting all items
  • BG-I25264 Device learning dialogs: identify command was sent in too many situations (e.g. after editing of device properties)
  • updated Alexa (0.4.0) and Husqvarna (1.0.8) addons
  • BG-I27413 RS485 Extension shows device limitation
  • BG-I27462 PS & B not in a room from planning tool
  • BG-I27369 Sequence Controller does not output “%” sign
  • BG-I26196 Automatic designer: API connector not working
  • BG-I27739 Window remanence of current position not working
  • BG-I27739 Window has a remanence parameter
  • BG-I22821 Find and Replace All replaces goes through all objects twice
  • BG-I27551 Backup webservice uses too much RAM use SD card for storing files instead
  • Increased some font sizes
  • BG-I27442 Status: Output does not show all decimal places in LiveView/Simulation
  • BG-I27418 Project Backups don’t show full note if project path contains special characters
  • BG-I27507 Managed Tablet: Childs (e.g. Online status) don’t take over room of tablet
  • Virtual HTTP command recognition window cant retrieve data from Miniserver anymore
  • BG-I27506 Error output state of sensors/inputs not remanent
  • BG-I27552 Miniserver search: Increased minimum size for buttons
  • BG-I27553 Exchanged Miniserver search and keychain buttons
  • BG-I27227 KNX Monitor: showed wrong device name for extended actors in some instances
  • BG-I27227 LiveView: no yellow highlight for negative values on analogue sensors
  • BG-I26846 IO from another Miniserver controlled via LiveView shows wrong value after page change
  • Managed Tablets: Version not displayed in device status & battery level shown in red
  • Plugin mTLS authentication not working in some cases
  • BG-I27382 Window without text can be selected in the mode ‘Freely position windows’
  • Program shown as not identical when loading from Miniserver
  • Plugin shown offline in device status
  • BG-I27378 Input references not always sorted in front of function blocks in the list which is handled by the SPS resulting in different behaviours depending on the insertion order
  • M-Bus Extension: devices show invalid secondary addresses starting with 7F:FF:FF:FF
  • BG-I23250 DALI light is turned WHITE and then RED and we send only RED to it
  • BG-I27323 Ac Control: AutoConnect for Temperature and Window Contact
  • BG-I27279 Tree-icon inverted in Device status & Quick search
  • BG-I27455 Unpair warning message is shown when deleting a trusted intercom
  • BG-I27456 Managed Tablet App Location Filter shows duplicate results
  • Disabling default software rendering (since it caused problems on some multi-monitor setups)
  • can be reenabled with LX_SOFTWARE_RENDERING=1 env variable where needed
  • Miele@Home Update translationsBG-I28087 Wrong error message when trying to insert logger/mailer/caller on a different Miniserver
  • Config connects locally with the external address to the Miniserver if the internal address is missing in the Keychain
  • BG-I28117 Config Caption bar shows ‘connecting’ but it already has failed
  • Miniserver Backup via webservice fails due to watchdog timeout
  • Home Connect: Rate limit is hit when plugin starts
  • Removed preselection of save path when saving documents
  • Hidden feature which leads to errors when project was copied
  • BG-I28187 Miniserver is unable to download auto update within the defined timeout of 3 minutes -> doubled the timeout
  • BG-I28130 Miniserver Keychain: Connect to remote connect Miniserver fails with error message
  • Read System messages not set to unread when being retriggered (e.g. Audioserver Spotify info messages)
  • BG-I28329 HealthCheck selection: remove option for MS-Gen1 Miniserver-Diagnosis
  • Device Status: Actions for tree-branches on client miniserver executed on wrong miniserver
  • BG-I28278 Miniserver-Diagnosis fixed typo when client miniserver is offline
  • BG-I28277 Link/Tree Diagnosis stuck when client miniserver is offline
  • BG-I28138 Managed Tablet is not shown with correct name in Control History
  • BG-I28293 Race Condition when starting update on different Miniservers in parallel, resulting in project mix-up
  • BG-I28274 No message when doing search & replace and text was not found
  • BG-I28230 Miniserver Connection: Wrong error message when Miniserver is registered but does not have Internet
  • Converted stored connection data is incorrect for Miniserver Gen.1 which use CloudDNS since it has stored an outdated resolved IP
  • BG-I28354 & BG-I28154 Intercommunication: Empty text or text starting with special characters not sent
  • BG-I28168 LiveView: Intercommunication T5 output can’t be switchedBG-I28148 Sequence Controller: focus lost when renaming variables/inputs/outputs
  • BG-I26198 Sequence Controller: changing variable name does not replace variables in all sequence pages
  • BG-I28318 Connection reference on math function block does not show a value in LiveView/Simulation
  • BG-I28384 Drag and Drop multiselection allows connection of an output to an input and vice versa
  • Possible queue overflows when sending messages to Link or internal Tree of Miniserver
  • BG-I28293 Race Condition when two configs save to a Miniserver in parallel

Devices & Extensions

  • Nano Dimmer Air US
  • BG-I27499 No system status message for short circuit
  • Fix for production test
  • System temperature is sent two times after startup
  • Extend air diagnosis on Door and Window Contact Air, Touch Air and NFC Code Touch Air
  • Dali
  • DALI fading time bugfix for smart actuators
  • BG-I23250 DALI light is turned WHITE and then RED and we send only RED to it
  • DALI address 0 starts identifying when the DALI extensions is identified
  • Reconnect to Audioserver after saving to Miniserver takes very long
  • BG-I27719 Touch Pure Flex: Long button press does not properly reset back to zero when releasing the button
  • M-Bus Extension: Do not monitor 8-bit M-Bus device status field due to a high number of false positives
  • Dali Firmware 14.07.02.08
  • BG-I27853 fixed control of DALI actors
  • Random DALI identify
  • Miniserver, Miniserver Go, Miniserver Compact coprocessor Firmware 14.7.2.14
  • Fixed multiple routing of messages to Link interface
  • Fixed initialization of internal Tree
  • Improved error statistics
  • Tree Extension Firmware 14.7.2.14
  • Fixed multiple routing of link legacy packets causing lost packets under high bus load
  • Fixed possible missed packets on Tree branches under high bus load
  • Fixed possible delays when one Tree branch is faulty or unused causing lost packets under high bus load
  • Improved error statistics
  • Nano DI Tree Firmware 14.7.2.14
  • BG-I18791 Fixed possible packet losses
  • Touch Tree Firmware 14.7.2.14
  • BG-I23335 Fixed possible packet losses
  • Extension Firmware 14.7.2.14
  • BG-I18935 Extension sends inputs delayed
  • BG-I18613 Touch Pure Flex: Config does not allow characters (# & $) even if they are supported by the device

Shading

  • BG-I27030 Geiger SOLIDline ZIP Air: dwc input not working after Obstacle detected

Audio

  • BG-I28113 Audio Player: end of presence does not pause manually started music
  • BG-I28114 Audio Player: presence does not start music during active event
  • BG-I28146 Audio Player: outputs V+/V# trigger when no music is playing
  • BG-I28137 Music Extension: no System messages shown when extension is not used on a Player
  • Music Extension: add System message for high CPU Temperature
  • Miniserver creates invalid init message when connecting to network devices (Audioserver, Intercom) causing pairing errors (invalid Base64 encoding)
  • BG-I28305 Audio Player: Bell immediately stops on falling edge of input instead of playing the whole file
  • BG-I28353 Audio Central: TTS retriggered on SPS restart
  • BG-I28385 Audio Player: Event stays active after restart
  • BG-I27958 fix USB/SD Content mixed up in wrong order
  • BG-I27892 cleanup of tts files when exceeding 100M, changed to delete files >= 2d (was 7d)
  • BG-I27916 fix crash in TunineSourceFinder
  • BG-I28037 fixed issue with Radio Station that sends stream instead of m3u urls
  • BG-I28404 fixed missing Contextual Info in Queue view
  • BG-I28358 fixed adding custom urls Streaming Servers that do not support HEAD Requests
  • Issue where spotify locally started causes other Players in fixed group (singlemode) to start too.
  • Eemoved Stream Prebuffering causing latency issues in Radio playback
  • Spotify no playback but shows visual playback (former spotifyconnect patch)
  • ‘New Audioserver Software’ reports did not work due to timeouts
  • Stream Error Handling for unplayable streams improved
  • Race conditions that can cause a crash on event playback
  • Performance optimizations for Miniserver Compact Audio distribution on local Tree Turbo
  • Volume+ command on muted playergroup causing the volume to increase on one player
  • Player Default Volumes did not sync on startup could cause unexpected behaviour
  • Issue where System Status Messages and Callback Actions were not reliably forwarded
  • Custom Sound Event Volumes

Climate

  • BG-I27771 Intelligent Room Controller: Multiple history entries when starting timer during manual calendar temperature
  • BG-I28129 Intelligent Room Controller: Presence does not extend Comfort mode started by input “C”
  • Intelligent Room Controller: improved text for history-entry “source blocked”

Lighting

  • BG-I27718 Lighting Controller: Inconsistent Capitalization in English
  • Light controller: invalid output value for rgb-only smartactors

Energy

  • BG-I27409 Copy of Wallbox which is managed by Wallbox Manager
  • BG-I27053 Wallbox: limitation via Api connector not remanent
  • BG-I27525 Wallbox Manager: Change of priority price not directly forwarded to Wallboxes
  • BG-I26303 Wallbox: Lcl output doesn’t use specified unit
  • BG-I26268 Wallbox Gen.1: wrong calculation of E1/E2
  • BG-I27927 Wallbox: System message Supply drop can’t be quitted
  • BG-I26899 Wallbox behaving incorrectly when Vc output is inverted
  • Wallbox Manager: Loads not activated
  • Quick Search: Energy Flow Monitor not shown as top result
  • BG-I27705 Energy Flow Monitor: Rest node does not use defined units

Multiplicator

  • BG-I27242 Multiplicator: Miniserver dialog allows duplicate serials
  • BG-I27508 Multiplicator: Disinheriting also goes across input references this results in disinheritance of large logic blocks even if they only connection is using the same inputs
  • BG-I28153 Multiplicator: Custom Changes (Expert mode) on disinherited controls removes them from project when loading from Miniserver

Trust

  • BG-I27820 Trust user group disappears
  • Trust Webservices not working anymore
  • Trust Link authentication not working

Auto Configuration

  • BG-I27314 Dali outputs used even if they are already in a group
  • Managed Tablet can get created multiple times
  • BG-I27684 Removed unnecessary control hint text

Diagnostics

  • BG-I27867 Tree Monitor does not show all information for intercommunication packets
  • Link Monitor displays wrong commands

Project Planning

  • BG-I27402 Special characters in room and category names
  • BG-I28028 Audio products are planned with the peak power usage

Stability

  • High SPS CPU load when there are lots of online states in the project
  • Miniserver reboot when receiving invalid text memory value from a client
  • Miniserver reboot when syncing of files to SD card takes too long
  • Config hangs when saving project
  • BG-I27532 Config crash when starting dali learning dialog
  • BG-I27538 Config crash when deleting entries from Miniserver Keychain
  • BG-I27339 Config crash when loading from Miniserver
  • BG-I27589 Config crash when opening default screen setting of managed tablets from setting dialog
  • Trust: Miniserver reboot when user is deleted due to race condition
  • BG-I27619 Config crash when importing project
  • BG-I27821 Config crash when saving to Miniserver
  • BG-I27909 Config crash when loading from Miniserver
  • BG-I27639 Config crash when doing an Undo while Monitor was opened
  • BG-I28182 Config crash when opening Wallbox Manager or EFM dialog out of setting edit dialog
  • BG-I28018 Config crash when resetting multiplicator changes
  • BG-I27821 Config crash when saving to Miniserver
Receive Important Update Messages Stay tuned for upcoming Loxone Miniserver Go updates

Was the content helpful to you?

Advertisement Advertise here?
Basalte Fibonacci Banner