Update

Add a Shortcut to another Miniserver

New

  • Miniserver Shortcut function block
  • Add a Shortcut to another Miniserver within the visualization
  • A3D9-T1036: Status Monitor
  • Keep an eye on your devices, states, and values with our new generic monitoring block
  • Door And Window Monitor:
  • Allow nesting of Door and Window Monitor objects
  • Allow select of gate controller
  • Meter: Detection and prevention in invalid Meter Readings
  • Decreases in the Meter Reading are not allowed anymore
  • Major increases are detected
  • An invalid change is now detected when the single meter change is bigger than the current Meter Reading and bigger than 10000
  • Only if the time difference since the last value change is smaller than 8h
  • User will be informed via System Message
  • System Message can be deactivated
  • Network Devices: Address Resolve Fallback
  • If the Miniserver fails to connect to the defined hostname/address it will try to find the correct address by searching for the device in the network
  • This enables a connection to the device even if the network settings were misconfigured
  • Hostname entered but the device set to a static IP
  • IP entered but the device has gotten a new IP via DHCP
  • Supported on Miniserver Gen.2 for Loxone Network Devices (Audioserver, Intercom)
  • Added Portuguese
  • Loxone Config Instance handling
  • When a config is already running double clicking a project file now will not start an additional instance of Loxone Config
  • NFC Authentication Block: Import NFC Tags and Access Codes from CSV
  • BG-I25937 Scene: Added LineIn action
  • BG-I27642 Burglar Alarm: add support for combined window contact
  • New Miniserver Connect Dialog
  • New Miniserver Keychain Dialog
  • A3D9-T1121 User Import: Import NFC Tags and Access Codes from CSV
  • Hardened security: Webservices need to be authenticated with a token with the proper rights, when a token is used
  • A3D9-T1085 Window: Added output for target position and input for current position (Can be used with Schüco Windows)
  • Matter (0.3.0)
  • various fixes
  • upgraded to Matter 1.2
  • M-Bus Device: Add sequence number property to analogue inputs
  • DALI extension firmware update DALI device types 0-6 support smart actors
  • A3D9-T1035 Automatic Designer: add action “Gate: partially open”

Fixed

General

  • Ac Control: Wrong type text used for gree/sinclair ac control
  • BG-I28029 Admin Interface reachable when configuring via Internet is disabled
  • BG-I27980 Central Shading: Safety-Reason for “Wa” not remanent
  • BG-I27953 Tree-Filter does not compare room/category names
  • BG-I28023 Network Intercommunication: Smart/T5-sensors not received when using encryption
  • BG-I27543 Tuneable white Dali dimmer is not working when the colour temperature is not used
  • Memory Leak when converting document
  • BG-I26050 Device learning dialogs: same device couldn’t be learned out and in again in the same learning session
  • BG-I26046 Saving project to Miniserver while device diagnostics were running left diagnostics in undefined state
  • BG-I28019 room settings (Combobox settings in general) didn’t work as expected in learning dialogs
  • BG-I27690 Devices with a single sub device were merged
  • BG-I27475 Documentation has missing descriptions for IOs
  • BG-I27693 Optical/Audible identify context menu action not disabled when not connected to the Miniserver
  • BG-I27761 Auto Connect to Miniserver does not properly use address settings from project as fallback
  • BG-I27687 Generic View Column filters not showing ampersands
  • BG-I27688 Unable to distinguish Miniserver captions in template insertion dialog
  • BG-I27834 Network device search uses full qualified hostname, this leads to problems when the domain changes
  • BG-I27722 Connection of memory flag gets lost when changing referenced object via settings
  • BG-I26559 External IO/Memory Flags are not sent to other Miniserver when value changes at SPS restart
  • Addon webservice does not check token rights
  • Tokens marked for deletion still work as Bearer Token for some time
  • An Error message is displayed when using multiple virtual UDP inputs with the same port, even if it does not cause any problems
  • BG-I27702 Ac Control Air Dialog: prevent unselecting all items
  • BG-I25264 Device learning dialogs: identify command was sent in too many situations (e.g. after editing of device properties)
  • updated Alexa (0.4.0) and Husqvarna (1.0.8) addons
  • BG-I27413 RS485 Extension shows device limitation
  • BG-I27462 PS & B not in a room from planning tool
  • BG-I27369 Sequence Controller does not output “%” sign
  • BG-I26196 Automatic designer: API connector not working
  • BG-I27739 Window remanence of current position not working
  • BG-I27739 Window has a remanence parameter
  • BG-I22821 Find and Replace All replaces goes through all objects twice
  • BG-I27551 Backup webservice uses too much RAM use SD card for storing files instead
  • Increased some font sizes
  • BG-I27442 Status: Output does not show all decimal places in LiveView/Simulation
  • BG-I27418 Project Backups don’t show full note if project path contains special characters
  • BG-I27507 Managed Tablet: Childs (e.g. Online status) don’t take over room of tablet
  • Virtual HTTP command recognition window cant retrieve data from Miniserver anymore
  • BG-I27506 Error output state of sensors/inputs not remanent
  • BG-I27552 Miniserver search: Increased minimum size for buttons
  • BG-I27553 Exchanged Miniserver search and keychain buttons
  • BG-I27227 KNX Monitor: showed wrong device name for extended actors in some instances
  • BG-I27227 LiveView: no yellow highlight for negative values on analogue sensors
  • BG-I26846 IO from another Miniserver controlled via LiveView shows wrong value after page change
  • Managed Tablets: Version not displayed in device status & battery level shown in red
  • Plugin mTLS authentication not working in some cases
  • BG-I27382 Window without text can be selected in the mode ‘Freely position windows’
  • Program shown as not identical when loading from Miniserver
  • Plugin shown offline in device status
  • BG-I27378 Input references not always sorted in front of function blocks in the list which is handled by the SPS resulting in different behaviours depending on the insertion order
  • M-Bus Extension: devices show invalid secondary addresses starting with 7F:FF:FF:FF
  • BG-I23250 DALI light is turned WHITE and then RED and we send only RED to it
  • BG-I27323 Ac Control: AutoConnect for Temperature and Window Contact
  • BG-I27279 Tree-icon inverted in Device status & Quick search
  • BG-I27455 Unpair warning message is shown when deleting a trusted intercom
  • BG-I27456 Managed Tablet App Location Filter shows duplicate results
  • Disabling default software rendering (since it caused problems on some multi-monitor setups)
  • can be reenabled with LX_SOFTWARE_RENDERING=1 env variable where needed
  • Miele@Home Update translationsBG-I28087 Wrong error message when trying to insert logger/mailer/caller on a different Miniserver
  • Config connects locally with the external address to the Miniserver if the internal address is missing in the Keychain
  • BG-I28117 Config Caption bar shows ‘connecting’ but it already has failed
  • Miniserver Backup via webservice fails due to watchdog timeout
  • Home Connect: Rate limit is hit when plugin starts
  • Removed preselection of save path when saving documents
  • Hidden feature which leads to errors when project was copied
  • BG-I28187 Miniserver is unable to download auto update within the defined timeout of 3 minutes -> doubled the timeout
  • BG-I28130 Miniserver Keychain: Connect to remote connect Miniserver fails with error message
  • Read System messages not set to unread when being retriggered (e.g. Audioserver Spotify info messages)
  • BG-I28329 HealthCheck selection: remove option for MS-Gen1 Miniserver-Diagnosis
  • Device Status: Actions for tree-branches on client miniserver executed on wrong miniserver
  • BG-I28278 Miniserver-Diagnosis fixed typo when client miniserver is offline
  • BG-I28277 Link/Tree Diagnosis stuck when client miniserver is offline
  • BG-I28138 Managed Tablet is not shown with correct name in Control History
  • BG-I28293 Race Condition when starting update on different Miniservers in parallel, resulting in project mix-up
  • BG-I28274 No message when doing search & replace and text was not found
  • BG-I28230 Miniserver Connection: Wrong error message when Miniserver is registered but does not have Internet
  • Converted stored connection data is incorrect for Miniserver Gen.1 which use CloudDNS since it has stored an outdated resolved IP
  • BG-I28354 & BG-I28154 Intercommunication: Empty text or text starting with special characters not sent
  • BG-I28168 LiveView: Intercommunication T5 output can’t be switchedBG-I28148 Sequence Controller: focus lost when renaming variables/inputs/outputs
  • BG-I26198 Sequence Controller: changing variable name does not replace variables in all sequence pages
  • BG-I28318 Connection reference on math function block does not show a value in LiveView/Simulation
  • BG-I28384 Drag and Drop multiselection allows connection of an output to an input and vice versa
  • Possible queue overflows when sending messages to Link or internal Tree of Miniserver
  • BG-I28293 Race Condition when two configs save to a Miniserver in parallel

Devices & Extensions

  • Nano Dimmer Air US
  • BG-I27499 No system status message for short circuit
  • Fix for production test
  • System temperature is sent two times after startup
  • Extend air diagnosis on Door and Window Contact Air, Touch Air and NFC Code Touch Air
  • Dali
  • DALI fading time bugfix for smart actuators
  • BG-I23250 DALI light is turned WHITE and then RED and we send only RED to it
  • DALI address 0 starts identifying when the DALI extensions is identified
  • Reconnect to Audioserver after saving to Miniserver takes very long
  • BG-I27719 Touch Pure Flex: Long button press does not properly reset back to zero when releasing the button
  • M-Bus Extension: Do not monitor 8-bit M-Bus device status field due to a high number of false positives
  • Dali Firmware 14.07.02.08
  • BG-I27853 fixed control of DALI actors
  • Random DALI identify
  • Miniserver, Miniserver Go, Miniserver Compact coprocessor Firmware 14.7.2.14
  • Fixed multiple routing of messages to Link interface
  • Fixed initialization of internal Tree
  • Improved error statistics
  • Tree Extension Firmware 14.7.2.14
  • Fixed multiple routing of link legacy packets causing lost packets under high bus load
  • Fixed possible missed packets on Tree branches under high bus load
  • Fixed possible delays when one Tree branch is faulty or unused causing lost packets under high bus load
  • Improved error statistics
  • Nano DI Tree Firmware 14.7.2.14
  • BG-I18791 Fixed possible packet losses
  • Touch Tree Firmware 14.7.2.14
  • BG-I23335 Fixed possible packet losses
  • Extension Firmware 14.7.2.14
  • BG-I18935 Extension sends inputs delayed
  • BG-I18613 Touch Pure Flex: Config does not allow characters (# & $) even if they are supported by the device

Shading

  • BG-I27030 Geiger SOLIDline ZIP Air: dwc input not working after Obstacle detected

Audio

  • BG-I28113 Audio Player: end of presence does not pause manually started music
  • BG-I28114 Audio Player: presence does not start music during active event
  • BG-I28146 Audio Player: outputs V+/V# trigger when no music is playing
  • BG-I28137 Music Extension: no System messages shown when extension is not used on a Player
  • Music Extension: add System message for high CPU Temperature
  • Miniserver creates invalid init message when connecting to network devices (Audioserver, Intercom) causing pairing errors (invalid Base64 encoding)
  • BG-I28305 Audio Player: Bell immediately stops on falling edge of input instead of playing the whole file
  • BG-I28353 Audio Central: TTS retriggered on SPS restart
  • BG-I28385 Audio Player: Event stays active after restart
  • BG-I27958 fix USB/SD Content mixed up in wrong order
  • BG-I27892 cleanup of tts files when exceeding 100M, changed to delete files >= 2d (was 7d)
  • BG-I27916 fix crash in TunineSourceFinder
  • BG-I28037 fixed issue with Radio Station that sends stream instead of m3u urls
  • BG-I28404 fixed missing Contextual Info in Queue view
  • BG-I28358 fixed adding custom urls Streaming Servers that do not support HEAD Requests
  • Issue where spotify locally started causes other Players in fixed group (singlemode) to start too.
  • Eemoved Stream Prebuffering causing latency issues in Radio playback
  • Spotify no playback but shows visual playback (former spotifyconnect patch)
  • ‘New Audioserver Software’ reports did not work due to timeouts
  • Stream Error Handling for unplayable streams improved
  • Race conditions that can cause a crash on event playback
  • Performance optimizations for Miniserver Compact Audio distribution on local Tree Turbo
  • Volume+ command on muted playergroup causing the volume to increase on one player
  • Player Default Volumes did not sync on startup could cause unexpected behaviour
  • Issue where System Status Messages and Callback Actions were not reliably forwarded
  • Custom Sound Event Volumes

Climate

  • BG-I27771 Intelligent Room Controller: Multiple history entries when starting timer during manual calendar temperature
  • BG-I28129 Intelligent Room Controller: Presence does not extend Comfort mode started by input “C”
  • Intelligent Room Controller: improved text for history-entry “source blocked”

Lighting

  • BG-I27718 Lighting Controller: Inconsistent Capitalization in English
  • Light controller: invalid output value for rgb-only smartactors

Energy

  • BG-I27409 Copy of Wallbox which is managed by Wallbox Manager
  • BG-I27053 Wallbox: limitation via Api connector not remanent
  • BG-I27525 Wallbox Manager: Change of priority price not directly forwarded to Wallboxes
  • BG-I26303 Wallbox: Lcl output doesn’t use specified unit
  • BG-I26268 Wallbox Gen.1: wrong calculation of E1/E2
  • BG-I27927 Wallbox: System message Supply drop can’t be quitted
  • BG-I26899 Wallbox behaving incorrectly when Vc output is inverted
  • Wallbox Manager: Loads not activated
  • Quick Search: Energy Flow Monitor not shown as top result
  • BG-I27705 Energy Flow Monitor: Rest node does not use defined units

Multiplicator

  • BG-I27242 Multiplicator: Miniserver dialog allows duplicate serials
  • BG-I27508 Multiplicator: Disinheriting also goes across input references this results in disinheritance of large logic blocks even if they only connection is using the same inputs
  • BG-I28153 Multiplicator: Custom Changes (Expert mode) on disinherited controls removes them from project when loading from Miniserver

Trust

  • BG-I27820 Trust user group disappears
  • Trust Webservices not working anymore
  • Trust Link authentication not working

Auto Configuration

  • BG-I27314 Dali outputs used even if they are already in a group
  • Managed Tablet can get created multiple times
  • BG-I27684 Removed unnecessary control hint text

Diagnostics

  • BG-I27867 Tree Monitor does not show all information for intercommunication packets
  • Link Monitor displays wrong commands

Project Planning

  • BG-I27402 Special characters in room and category names
  • BG-I28028 Audio products are planned with the peak power usage

Stability

  • High SPS CPU load when there are lots of online states in the project
  • Miniserver reboot when receiving invalid text memory value from a client
  • Miniserver reboot when syncing of files to SD card takes too long
  • Config hangs when saving project
  • BG-I27532 Config crash when starting dali learning dialog
  • BG-I27538 Config crash when deleting entries from Miniserver Keychain
  • BG-I27339 Config crash when loading from Miniserver
  • BG-I27589 Config crash when opening default screen setting of managed tablets from setting dialog
  • Trust: Miniserver reboot when user is deleted due to race condition
  • BG-I27619 Config crash when importing project
  • BG-I27821 Config crash when saving to Miniserver
  • BG-I27909 Config crash when loading from Miniserver
  • BG-I27639 Config crash when doing an Undo while Monitor was opened
  • BG-I28182 Config crash when opening Wallbox Manager or EFM dialog out of setting edit dialog
  • BG-I28018 Config crash when resetting multiplicator changes
  • BG-I27821 Config crash when saving to Miniserver