Upload your projects to the cloud

New

  • Loxone Exosphere Integration
  • Upload your projects to the cloud
  • Save Credentials to your Exosphere workspace and share them with your colleagues
  • Support for Master/Client Speakers
  • Dali Extension DALI2 support
  • Only for certified Extensions
  • BG-T3186 Audio Player: Control History
  • A3D9-T1110: NFC Code Touch authentication method parameter
  • The authentication method can be changed through this parameter via logic
  • Health Check for Audio
  • A3D9-T1193 Audio Player: Setting “Room favourite priority”
  • If checked the Audio Player always starts with the first favourite
  • Multiplicator: Allow reset changes of a setting on all managed Miniserver with one action within edit dialog in Multiplicator project
  • Ventilation: Use a PI controller for CO2 control
  • Parameters depending on room size
  • A3D9-T975 Energy Flow Monitor: Automatic Designer support
  • supports conditions for grid power, production power, storage power and more.
  • A3D9-T1156 Wallbox Manager: more intelligent distribution
  • Energy of not actively charging Wallboxes is allocated to other Wallboxes
  • New binary for Water Sensor Air and Door and Window Contact Air: display system message when button is stuck
  • A3D9-T1164 Wallbox Price Inputs
  • added webservice (/dev/sys/updatetolatestrelease) to update Miniserver to latest release
  • A3D9-T1046 Window Handle: Tilt Position (Tilt Before Open)
  • A3D9-T1076 Negation of digital Inputs
  • A3D9-T1155 Admin Password Reset Protection
  • New Project Setting ‘Disable Password Reset’ that prevents resetting of admin password
  • BG-T3288 Autoconfig: Energy Improvements
  • New Comfort Function for Energy Flow Monitor
  • Creates Energy Flow Monitor
  • Meters are added
  • Grid Meter is set to ‘Grid’
  • Wallbox meters are added
  • Power Supply & Backups are added
  • Version 15 Splash Screen
  • Added button for manual connect to ribbon connect submenu
  • BG-I13568: RGBW Dimmer Tree is now able to be added to a lightgroup
  • Nano IO Touch V1: buttons can be pressed longer than 20sec
  • Ceiling Light Tree: different brightness sensors are supported

Fixed

General

  • Some texts in Project management View were not translated correctly
  • BG-I28145 System Schematic: dependency loop possible to configure where one system schematic uses the visualization of the other
  • BG-I28386 NFC Authentication: Off input does not reset all outputs
  • BG-I21712 Remanence: Remanence of T5 input was saved which caused Lighting Controller to change mood when saving into MS
  • BG-I23142 Climate Controller: Does not sort list with selected objects on top
  • Project Size calculation makes big jumps when adding many clients
  • System Status: Many changed events on gateway systems even if nothing has changed
  • BG-I28451 Watchdog Reboot while doing Miniserver backupBG-I28401 Device status: add “start diagnosis” for Tree2Air-Bridge
  • BG-I28247 Network Device Pairing: improved System-Message when encountering errors
  • BG-I28155 Gate Controller: renaming control does not rename referenced Hörmann-Device
  • BG-I28910 corrected misleading appearance of tabs user permissions dialog
  • BG-I28486 incorrect encryption column data and removed misleading error column in NFC monitor
  • BG-I28897 long startup time when Config tries to load backups stored on network drives
  • BG-I28583 possible deadlock in Matter plugin
  • BG-I25884: tree communication fixes when falsely connected
  • BG-I28523: Techreport starts orientation light
  • BG-I15326 Format Dialog close button is named “Cancel” after finishing a format
  • BG-I28963 Switching time can’t be edited with double click
  • BG-I28732 Managed Tablet dialog: Button text not translatable
  • BG-I28995 System messages: Added more info to entries in def.log (serial number, room)
  • Meters: Automatic statistic deletion enabled per default
  • BG-I18120 Copy-Pasting BACnet IO causes duplicate IDs
  • BG-I25288 & BG-I16183: SIA keeps old failed messages across sps restarts and continues to retry them
  • BG-I23285 RS232/RS485 learn dialog also adds checksums (if enabled) to the command recognition
  • BG-I28584 Systemstatus Dialog: read indicator incorrect when reopening dialog
  • BG-I29030 Threshold Switch: undefined behaviour when input value to large
  • BG-I28912 Display Settings: Status-text not shown in certain configurations
  • BG-I29109 Status Monitor: No text generated at output Txlc when logic block was connected
  • BG-I29024 Block History: Lock by user in App does not show the user
  • BG-I26201 “Device assigned” text on blocks with common Api connectors
  • BG-I26720 Operating times with / in name cannot be edited via app
  • BG-I29057 Window: Target position not updated during protection movement
  • BG-I29032 fixed cover page for DI Extension
  • BG-I28968 AC Control Air: Invalid Device Type in App-Search
  • BG-I27934 Print Document: page order of devices now represents order in tree
  • BG-I27085 Emergency/AAL Alarm: device name instead of sensor name used for text output
  • Digital Inputs: Inverted input text not marked red
  • BG-I28993 Status Monitor: Description text not used for function block history and Txlc output
  • BG-I28808 Status Monitor: App navigation not possible for objects connected to input ‘Stat’ without visualization enabled
  • Restricted Visualization: Attribute was not removed if object didn’t need it anymore
  • Exosphere: corrected mTLS connection handling
  • BG-I22854 Tree Extension: old popup message when activating tree intercommunication on dummy tree extension
  • BG-I28631 Miniserver Keychain: Credentials not saved when connected via Miniserver Search
  • BG-I28466 API/Webservices: /astate returned value from /state
  • BG-I28738 Status Monitor: Tlxc output used name of device instead of input
  • fixed crash learning multiple XAL devices
  • BG-I28740 Belimo Datapool device does not have unique connection ID
  • BG-I28749 Virtual input switches between analogue and digital after first connection
  • BG-I28773 DeviceStatus: Duplicate entries for Music Server Zones
  • BG-I27240 Property Window not updated after closing Intelligent Room Controller Dialog
  • BG-I27236 Expert Mode: user can move objects to rooms without permission
  • BG-I28473 Device command context-menu not available for Miniserver-Tree
  • BG-I28549 Sequence Control Dialog: Adapted Tab-size
  • BG-I28650 Cabinet of Tree Turbo cannot be used from Audioserver or Miniserver
  • BG-I28595 Device Status: removed context-menu “diagnosis” for single devices
  • BG-I24011 Text Generator: line breaks not properly set on output
  • BG-I28373 System Message: No message when automatic update fails
  • BG-I28441 Connect Miniserver: Wrong error message displayed because validity of Miniserver serial number not being checked
  • BG-I28571 Property Window: Editing Miniserver serial number of trust manager did not update serial number in trust section
  • BG-I28083 HTTP Monitor: some ok http codes marked red in monitor
  • BG-I28625 Status Monitor: deleting linked status monitor does not unlink from master
  • Status Monitor: unconfigured status incorrect in App
  • BG-I28325 Wrong page ordering after importing project
  • Wrong http return value for system status webservice when confirming custom system message
  • BG-I28539 Adding Miniserver as a client preselects an old address
  • Removed switch to program tree when searching via F5
  • BG-I29275 System Status: Historic Message is set to unread
  • Loading from Miniserver is slow when having a lot of system schematics
  • BG-I29471 Device Status has a slow performance and expands items which don’t have an error
  • BG-I28836 Push is sent delayed due to failing DNS resolves (Resolved IP is now kept updated)
  • BG-I29289 Alarm Clock: Alarm activates for past entries when operating modes change
  • BG-I29310 Alarm Clock: Tna output shows wrong time when next alarm is after a daylight savings change
  • BG-I29334 Monitors are not properly docked at the bottom of the config
  • BG-I28624: Door & Window Monitor Faulty app status on Client Gateway System when Gate or Window blocks are in use
  • BG-I29135: Intercom Search Dialog Configure device button enabled without search results
  • NFC Learn Dialog NFC Code Touch not preselected in certain cases
  • BG-I25498: NFC Learn: NFC Code Touch Air in battery operation doesn’t get learn mode packets
  • BG-I29346 Integrated shading: output set to 1.1 in config simulation
  • BG-I29285 Expert Mode: changes on input reverted when saving
  • BG-T2728 items are automatically collapsed in Device Status dialog
  • Client/Gateway: User update received via Trust sent via UDP to client resulting in a possible loss of the command
  • BG-I29092 HTTPS-Encryption: Removed unsecure TLS ciphers (TLS_DHE_RSA_WITH_AES_256_GCM_SHA384 & TLS_DHE_RSA_WITH_AES_128_GCM_SHA256)
  • BG-I28803 Webservice fails when it contains certain text parts
  • BG-I29248 Property window scrolls up when saving project
  • BG-I27950 Intercom: Shift auto update time depending on SN when default is used
  • BG-I29632 Tree diagnostics skipped when Tree2Air was the only device on the tree branch
  • Virtual Text Input can’t be inserted on another Miniserver
  • BG-I29266 AirDiagnostics: fixed wrong webservice call for Tree2Air devices
  • BG-I29215 NFC learning dialog: added error dialog if NFC tag couldn’t be be learned encrypted
  • BG-I29297 Status Monitor: duplicate Virtual Input in visualization when connected and visualization turned on
  • BG-I29243 EnOcean: Extension from Clients not selectable in Learn Dialog
  • BG-I29128 Configure Miniserver: Miniserver related tabs excluded from dialog when opened from configuration tree
  • BG-I29159 Cover page: Relay extension not displayed correctly
  • BG-I29439 Tree Search: Hardware version missing
  • Config crash when updating periphery tree when there is a touch & grill
  • BG-I29547 User created via App can’t login on a Client
  • BG-I29527 Burglar Alarm: Remanence when alarm is triggered by single sensor
  • BG-I29434 Lines to nowhere when cutting & pasting control which uses API connector
  • BG-I28449 Tesla Powerwall uses imbalanced Meter reading calculation added info to documentation
  • BG-I29573 Error message during Auto Update process directly set to historic
  • PicoC: Serial stream not created when name is ambiguous
  • BG-I29227 Meter for Storage: Storage level missing in automatic designer
  • BG-I28702 Sorting: Options of combo box not correctly alphabetically sorted
  • BG-I28029 Miniserver Configuration: could be changed remotely when remote configuration was disabled
  • BG-I29509 Lumitech Standard actor: invalid value in liveview for certain colour-temperatures
  • BG-I29219 Belimo Devices: Merged to Parent if only a single device was used
  • BG-I29174 Easter Incorrectly set in PL-Calendar
  • Modbus
  • BG-I26875 Modbus sensor unable to be read as digital
  • BG-I27973 Modbus RTU Function 15 not working
  • BG-I28170 Modbus RTU sending, but unable to receive
  • BG-I28695 Modbus Test Command
  • BG-I28843 Device Status: Diagnosis button does nothing when there is no item in the tree is selected
  • BG-I29241 Automatic Designer: Objects with room/category ‘do not use’ are not shown in dialog
  • BG-I22809 Changed ‘Allow password edit’ right of a user via app is not properly loaded from Miniserver
  • BG-I29497 Managed Tablet not shown with proper name in control history on gateway client system
  • BG-I29507 Learning Dialog shows no columns
  • BG-I29311 Dali Fade Rate setting has a misleading description
  • BG-I24495 Automatic Designer rule is triggered when saving to Miniserver on a client gateway system
  • BG-I29549 Remove Support community button from ribbon since it’s not valid anymore
  • BG-I29521 Monoflop: Remanence not working when time parameter is set via logic
  • BG-I29554 Connection references in a gateway system result in name in the visualization including the abbreviation
  • BG-I29619 Connect to new Miniserver preselects wrong address
  • BG-I29308 Miniserver thinks that Air device is asleep after keeping it awake via Device Status in some cases
  • BG-I29117 Config Auto Connect: uses external connection instead of internal in some cases
  • Display of device Tree View in HealthCheck dialog

Devices & Extensions

  • Touch Pure Air
  • BG-I24686 incorrect temperature/humidity measurement
  • Touch Pure Tree
  • internal improvements for error handling
  • BG-I28530: false clicks during tree diagnosis
  • BG-I29208 Webservice setting error
  • Touch Tree
  • Buzzer sound reverted to last release version
  • fix for old touches not reacting anymore
  • BG-I29208 Webservice setting error
  • Touch Pure Tree CO2
  • internal improvements for error handling
  • BG-I29208 Webservice setting error
  • Valve Actuator Air V2
  • learn button for 15sec active after power reset instead of 5, other various improvements
  • Valve Actuator Tree
  • BG-I26764 hardware error not shown in system status
  • AC Control Air Firmware: 14.07.02.09
  • BG-I26759 Mitsubishi Electric supports Aircons with different baud rate
  • BG-I25684 Daikin P1P2 vane position would affect fan speed when set to 0
  • Mitsubishi Heavy Industries force temperature range
  • Nano IO Air
  • BG-I26173 goes offline sporadically
  • Touch Surface Air
  • BG-I23268 no click sounds on T6 when LEDs aren’t visible
  • BG-I20671 visual feedback in calibration dialog not working
  • KNX Extension
  • BG-I27277 it’s possible to add more than 500 actors/sensors by cut/paste
  • XAL Light Air
  • fix for device feature readout
  • M-Bus
  • BG-I27408 M-Bus device Techem Type 4.1.1 can’t be learned in
  • Windows Handle Air V1
  • BG-I25470 Closed position “up” functions the same as “down”
  • Nano DI Tree
  • general communication improvements
  • Presence Sensor Tree
  • PIR sensitivity settings improved
  • BG-I28540/BG-I25543 implemented additional brightness value check to prevent excessive sending of brightness values
  • Presence Air
  • BG-I25344 Sensor not reacting during overrun time leading to sending of inactive even though motion is present
  • BG-I24985 Device sending move is active while being kept awake
  • Analog Out Extension:
  • BG-I17291 Sporadic change of output range
  • RGBW Dimmer Tree:
  • BG-I24397 Calculation of colour temperature and brightness values has been changed to a linear approach
  • BG-I18960 Firmware has been adapted, that the initial output state of the LED pins is disabled

Energy

  • BG-I24212 Energy Manager: not marked unconfigured when no valid load was defined
  • BG-I21676 Energy Manager: Minimum state of charge change in App doesn’t update in Config
  • Wallbox: Remanence not used for target power of manual mode 99
  • BG-I29033 Wallbox Manager has statistics activated by default even if it has none
  • BG-I29326 Wallbox Manager: Wrong calculation during phase switch of wallbox
  • BG-I29185 Spot Price Optimizer: Negative values do not work in simulation
  • BG-I29124 Wallbox Manager: Wallbox can no longer be added if previous Wallbox Manager was deleted in some cases

Trust

  • BG-I28315 Local admin does not see any objects in visualization
  • BG-I28570 Trust: Custom change after replacing trust manager leads to config crash
  • BG-I28413 Replace Miniserver Dialog: Trust Manager serial number not adapted
  • BG-I29165 Trust: Same user multiple times in project
  • Trust added logging to def.log when User management data update was not sent to another member
  • Added retry when update of user management data fails

Auto Configuration

  • BG-I28771 Incomplete ToDo for power failure operating mode
  • BG-I29022 Adapted tooltip for Audio-Column

Project Planning

  • BG-I28908 Added tooltip for installation location describing the creation of lighting groups for light products
  • BG-I28543 Damper has invalid name
  • BG-I29510 Project Planning: PWM channels with different names create additional dimmers

Climate

  • BG-I27790 Intelligent Room Controller: Initial value for ϑch / ϑcc not adapted for touch flex when changed via app
  • BG-I27886 Intelligent Room Controller: fixed setpoint not resetting after manually cancelling timer
  • BG-I28615: Intelligent Room Controller: valve output reduced when reaching heat protection temperature
  • BG-I29235 Intelligent Room Controller: Removed Climate controllers are not unregistered
  • BG-I29360 Climate Controller programmed on Gateway doesn’t see IRC blocks programmed on Client
  • BG-I29191 Intelligent Room Controller: Outputs shortly set to 100% on startup
  • BG-I29322 Climate Controller: always use current outdoor temperature as “average” in config simulation
  • BG-I29557 Locked Intelligent Room controller activates Climate Controller on Startup
  • BG-I29121 Intelligent Room Controller changing to fix target value causes invert of actual mode

Lighting

  • BG-I28860 Lightcontroller: incomplete history-entries created by central-block

Audio

  • BG-I28407 Audio Player: Music is not stopped after Event when input “Off” is active during Event
  • BG-I28511 Audio Player: invalid “off” command after multiple bell events
  • BG-I28527 Audio Group Fix und Central: V+ output not triggered
  • BG-I28408 Audio Group Fix + Central Music: Added Parameter Double-Click-Time (Tdc)
  • Music Extension: Temperature Shutdown sensor by CPU overtemperature reset by AMP thermal protection
  • Audioserver: “Separate Stereo Output” enabled for Line-In and SPDIF channels
  • BG-I23372 Audioserver Search Dialog Columns order not correct
  • BG-I28745 Audio Central doesn’t forward TTS events to Music Server zones
  • BG-I28724 Audio Player: TTS not executed when text contains ‘/’
  • BG-I23450 Audio Player: default room is only respected for first block when inserting multiple outputs unto the page
  • BG-I28780 Double klick on Audio Player Fixed Group’s inputs V+ and V causes pulses on Audio Player’s outputs V+ and V-
  • BG-I28850 Audio Central/Audioplayer group fix: Add property “ignore room off gesture”
  • BG-I28826 Audio Fixed Group Input Off does not stop Player after Event
  • BG-I28693 Missing Documentation for Stereo Extension
  • Split Audio Outputs cannot be assigned a speaker type
  • BG-I28994 Stereo Extension: System message does not contain serial number or room
  • BG-I23449 Stereo Extensions not sorted alphabetically
  • BG-I23436 Stereo Extension search: enable continuous search
  • BG-I29225 Audio Player: Update Player names after Expert Mode / Visu changes
  • BG-I29186 Audio Fixed Group: LineIn not forwarded to players
  • BG-I29083 Audioserver: Miniserver tries to send grouped command while websocket is not connected
  • BG-I29497 Audio Player History shows room next to Audioserver
  • BG-I29559 Audio Central doesn’t show TTS input when linked to a MuS zone

Diagnosis

  • Diagnosis Miniserver: Skip Internet-check if configured in system variable
  • BG-I28437 HealthCheck: stops on empty Air-Base

Multiplicator

  • Trust users have duplicates in programs with different permissions
  • BG-I27963 Changes in Logger/Mailer/Tracker settings not serialized
  • BG-I29470 Can’t add more than one API actor reference
  • BG-I29258 Assigning NFC or code to user is not serialized

Gateway/Client

  • BG-I28623 Gate Central can’t control gates on a client when it’s also used in door and window monitor

Stability

  • BG-I28537 Config Crash when cancelling diagnosis
  • Fixed config crash when saving into gateway-client with trust users
  • BG-I28690 Config Crash: loading from Miniserver while Air diagnosis is running
  • BG-I28858 Config crash when opening a config file via file browser
  • BG-I29236 Config crash when running for a longer time
  • Config crash during Link Health Check
  • BG-I29645 Config crash when learning tree device
  • Miniserver reboot when accessing invalid object via serial stream in picoc
  • BG-I29517 Miniserver update fails due to less RAM
  • BG-I29604 Miniserver Gen.1 Watchdog reboots when having a lot of systemstatus entries as a client
Version: 15.0.5.11 Link