Bringing new functionality improvements with multiple resolved issues
Improvements
- Energy Flow Monitor
- Wallbox function block
- New Meter function blocks
- Pulse Meter (Unidirectional, Bidirectional and with Storage)
- Meter (Unidirectional, Bidirectional and with Storage)
- Calculated Meter (for loads where only the On/Off status is known)
- App does not yet fully support the blocks!
- Energy Manager Gen.2
- Variable outputs
- Simpler configuration
- Input for forced recalculation
- Output for seconds until next recalculation
- Loxone Icon Library
- Select an Icon for your room, category, function block, or status out of more than 500 available icons
- Import custom Icons (png, jpg)
- All existing used icons will be converted to new ones
- Custom icons will remain untouched
- Icon editor has been removed from Config
- Icons for visualised state only objects need an updated app to be properly displayed!
- Icons for the status function block need an updated app to be properly displayed!
- New Monitor windows & learning dialogs
- Air Monitor
- Tree Monitor
- IR
- UDP
- DMX
- Dali
- Internorm
- EnOcean
- RS232/RS485
- NFC
- 1-Wire
- Link Monitor
- Modbus Monitor
- HTTP
- IR Meter Reader
- Air Added M-Bus support
- Sontex Supercal 739 and Itron CF Echo II can no longer be selected as meter types (use M-Bus instead)
- Added send interval property
- Some meter types can no longer be selected in new installations
- For Landis+Gyr E350/E550/E650, Itron ACE2000, Elster AS1440 and Iskra MT174 please use IEC62056-21
- For EMH 300L, EMH eHZ-I meters and Easymeter Q3C, please use SML
- For Itron CF echo II and Sontex Supercal 739, please use M-Bus
- Project Planning: Added Tree Intercommunication
- BG-I16697 Aquastar Air: Added cyclic sending for voltage input (every 15 minutes)
- New Setting for Air Touch products “ ButtonBehaviour”
- Behaviour of already existing projects not changed. Newly added devices will be set to pulse behaviour.
- When On/Off is set:
- Behaviour not changed compared to previous versions
- When pulse is set:
- automatic reconnect is deactivated pressing a button for more than 1 sec will trigger a reconnect
- battery consumption reduced to a minimum, packets are not retransmitted on packet loss
- New Firmware (13.01.07.12) for Air Touch products to support ButtonBehaviour option
- Nightlight Air
- Touch Air V1 & V2
- Touch Pure Air V1, V2 & V3
- NanoDimmer V1 & V2
- NanoIO V1 & V2
- NanoIO-US
- Touch Surface
- Added new EIB/KNX monitor and learning dialog
- Tunable White Feature added for Multi Extension Air and DMX Extension
- Text generator
- Create texts and trigger them by an event
- e.g. for TTS messages
- A3D9-T9 Added description of the device in object selection dialog window
- A3D9-T21 Added function to enable/disable validation system message
- A3D9-T849 Display a tooltip when a device/item has an active systemmessage and the user hovers with the mouse at the icon of the device
- Use new Weather-Service Server for testing of new service
- Automatic Air Pairing
- On Airbase for offline devices (e.g. unpaired devices where the mac address is entered manually)
- Learn Mode starts after Ms-Reboot (5 to 10 min delay) and is executed once per hour for 2 Minutes if there are any devices to pair
- Learn Mode stops if the given Date Setting on Airbase is passed
- A3D9-T558 Added category in cover page
- A3D9-T717 Added edge detection for the threshold switch
- A3D9-T407 Added toggle input for roof window
- A3D9-T407 Added synchronisation of central gate and roof window
- BG-I17949 Project Planning: Added pwm spots to preselection
- A3D9-T232 Formula Parser: Added IF functionality
- Examples:
- IF(I1>1;1;0)
- IF(I1*I2==0;I3;I4/2)
- A3D9-T573 AlarmClock: Added new output for next alarm time
- HTTP VirtualIn Command Recognition Edit dialog
- live testing of command recognition pattern
- only available when connected to Miniserver, otherwise the old dialog will be shown
- Reworked Devicestatus-Dialog
- A3D9-T858 Added text-to-speech input for central audio
- Convert Energy Monitor to separate new Meter objects via action in context menu
- BG-I18671 added initial column filtering based on selected control to monitors
- A3D9-T896 Added new operating mode for load manager: peak load manager (Beta)
- A3D9-T625 added search next/previous buttons and display of search result index/count to search in TechDoc and Changelog dialogs
Bug fixes
- BG-I17524 Plugin Child devices not shown in learning dialog
- BG-I17504 Update: Credential dialog after update may appear multiple times at once
- BG-I17492 Update: Credential dialog sizing improved
- BG-I17469 Invalid connector letters for devices (Weatherstation and IR Meter)
- BG-I17385 Modbus RTU: Add recovery for Rx overrun errors
- BG-I17259 Extension learning dialog allows add of more than 30 Extensions
- BG-I17188 Light Controller dialog: Initial scroll position not at the top BG-I17221 Extension serial cant be deleted
- BG-I17309 Control Linking Dialogs: Columns cant be resized
- Husqvarna: fixed sporadically not updating values of husqvarna mower objects
- BG-I16069 Device-Learning via App: unconfigured control after replacing dummy-device
- new Device information not shown on tree/link caption
- BG-I17284 Audioserver: Systemmessage shown on wrong music player
- Status-Dialog: Device-Command not available for Internal Airbase
- BG-I17311 Media Control: selected cells not visible, editing difficult
- BG-I17237 Events with Client/GW and AS in Stack Audio Player Fixed Group TTS not sending command
- BG-I17236 Events with Client/GW and AS in Stack Intercom Bell
- Category Icon colour cant be set to default
- BG-I17385 Modbus TCP: fixed 64Bit-Integer sensors
- BG-I17403 Stereo Extension has no visual identify option
- BG-I17347 System status action ‘ Show’ shows too many items
- BG-I17194 Selection Tables: Added text to checkbox column
- BG-I17370 Permission management dialog: Columns cant be resized
- BG-I17410 Project Validation shows statistics mailer as unused
- BG-I17420 KNX Sensors/Actors cant be created from monitor window
- BG-I17355 IRC: Better description when object is not completely configured
- BG-I17421 Expert Mode Light Controller: Current brightness is shown with too many decimals
- BG-I17332 Alarm: Window Handle from another Miniserver not displayed properly
- BG-I17443 Category dialog: Invalid description for category group
- Trust: User for member created twice when same Miniserver is member of different trusts
- BG-I17437 Modbus TCP: unreferenced actors are sent on startup
- QU1-I208 MS Compact conversion: create dummy extensions for omitted IO’ s
- Modbus Server: 64bit signed integer handled incorrectly
- Led Stati (expect Identify) for Touch Air and Touch Pure air only available in the first 10 minutes after a power on reset
- Delay Startup data for Touch Nightlight to avoid air channel overloading
- Generic Table: Invalid sorting in some dialogs (e.g. Touch Pure Flex, Load Manager,… )
- Saved Air & Tree Monitor cant be loaded
- BG-I17656 Touch Pure Flex: Calculation for text display duration not exact
- BG-I17586 LiveView has hidden buttons for controlling of outputs even when manual value change is not enabled
- BG-I17535 Auto Configuration: Tunable white actors in the same room are converted to smart actor
- BG-I17552 MS Compact: App cannot connect to Audio Player initially
- BG-I17566 Intercommunication outputs are sent even when they are not used
- BG-I16156 Client weather activation status overrides gateway status after some time, making it impossible to create automatic rule in the app with weather
- Utility Meter is now hidden please use new Meter function blocks instead
- BG-I17551 Audioserver: visual identify not working correctly
- TreeMonitor: Digital state displayed inverted
- AirHost (AirBase, MiniserverGo,… ) crashes: New Firmware for AirHosts Version 13.01.09.05
- WindowhandleV2: new firmware (Version 13.1.9.5) add recovery on communication loss
- BG-I17863 SMTPS mailer not working
- BG-I18226 T5 inputs get stuck in LiveView
- BG-I16590 KNX Gateway: invalid telegrams tunneled
- BG-I14614 NFC Code Touch: Assigning different NFC Code Touch version makes graphical bug
- BG-I17971 KNX/EIB: actuator sends once 0 after reboot
- BG-I18182 & BG-I18183: Weather Server not properly created in new projects
- A3D9-T407 fixed error in synchronisation for shades
- Improve drawing of additional names next to output abbreviations
- Window does not auto connect outputs
- Window Central: Dialog does not automatically open after inserting control
- BG-I18055 Extension Learning: Program still identical after learning
- BG-I17778 API Command generator: GETOUTPUT correct output is not selected when opening dialog
- BG-I17782 MENU Api Command: Selected value toggles between zero and defined start value when there is no value:text pair defined for the start value
- BG-I17741 Radio Button 16: Menu API command skips OFF
- BG-I17773 No room next to 1-Wire devices in document tree
- BG-I17793 Abbreviations not renamed in auto configuration todos
- BG-I18019 Invalid characters in configuration ID produce wrong error message
- BG-I17930 Random number generator: Minimum can be set above Maximum and vice versa
- BG-I17999 DMX Extension has invalid icon
- BG-I18027 Invalid currency symbol in new czech projects
- BG-I17979 State: Abbreviations not renamed in dialog
- BG-I17932 Disabling HTTPS on Miniserver does not remove all information for app connection
- BG-I18023 First activate of Default Alarm Clock entry resets alarm time to 00:00
- BG-I18076 Property Window: Disabled ComboBoxes have a drop down arrow