Update

Display Intercommunication ID next to Intercommunication caption in periphery tree

New

  • M-Bus Extension
  • BG-I26526 Expand childs of memory flag when selecting memory flag
  • Display Intercommunication ID next to Intercommunication caption in periphery tree
  • Nano Dimmer (US)
  • A3D9-T1029 Energy Flow Monitor: Provide statistic for rest
  • Wallbox Manager
  • Distribute available power to multiple Wallboxes
  • A3D9-T997 Simplification of math blocks: now all connections are considered for calculation in add, multiply, minmax and average operations
  • previously only the last changed value was used when an input had multiple connections
  • DALI data preparation changed for DALI Air support
  • DALI Air
  • Push Notifications: Support for new handling on iOS and Android devices
  • Separate permission to allow a user to trigger a Miniserver backup
  • Wallbox
  • Priority input (when used in combination with a Wallbox Manager) no behaves like the Enable charging input
  • Attention: This may change behaviour if you have already used the Prio input!
  • Priority charging is started with a short pulse (<1s)
  • When the pulse is longer then 1s charging is stopped again with the falling edge
  • Current mode output ‘M’ is now also available when managed by a Wallbox Manager
  • 0 = Charging not allowed
  • 1 = Eco charging allowed
  • 2 = Priority charging allowed
  • Access NFC Code Touch
  • Output Uidla now uses username as fallback when no User ID is set
  • XF1-T8 Add Support for XAL Lamp
  • Managed Tablets
  • Pair your wall mounted tablet with your Miniserver
  • No need to remember login credentials
  • Function Block support
  • Activate screen
  • Do not disturb
  • Screen brightness
  • Battery Level
  • Configure Ambient Mode in Loxone Config
  • A3D9-T1087 Added Miniserver-Healthcheck
  • Checks basic functionality like Network, Timeserver, CPU/Memory/SD-Usage

Fixed

General

  • BG-I26469 Recovery of communication loss
  • BG-I26492 Schedule-Dialog: no colour-info for access schedule
  • BG-I26317 Sequence Controller Return statement is ignored when opening dialog during simulation
  • BG-I26497 Text of merged object not updated in tree when dragged to page
  • BG-I26295 Mouse position is offsetted when a banner is displayed
  • BG-I26009 Update may fail
  • BG-I26192 Statistic deletion interval of meters of a power supply & backup is reset when loading from Miniserver
  • BG-I23901 HomeConnect update states after device was offline
  • BG-I26285 Mouse wheel scrolling changes selected ribbon while another dialog is opened
  • BG-I26325 Memory flag inputs don’t have automatically the colour of the output
  • BG-I26398 Miniserver deletion from client search dialog breaks project
  • BG-I26410 Usergroups not updated after a trust user is transferred
  • BG-I26403 Exporting client project creates unusable memory flags for connection references
  • BG-I26424 Objects not showing central info when used in Door and Window Monitor
  • BG-I26418 Internal tree of Miniserver tree not usable
  • BG-I25615 NFC function block shows a strange output name when deleting name of connected output in GUI
  • BG-I24914 NFC Code Touch does not react on off input
  • BG-I24106 Access denied now shows in the Config “Code …” or “NFC …”, also the user is shown if available
  • BG-I24267 Door and Window Monitor Fixed NOT function block filtering description of connected input
  • BG-I24873 Confirming burglar alarm configuration dialog sets program status to not identical
  • BG-I26124 Text for deactivated codes in the overview of authentication attributes
  • BG-I26202 Gate Controller: API connector not at last position
  • BG-I26221 Sequence Controller: tabulators in set commands are removed
  • BG-I26272 AC Control: Common devicetype shown when learned in with app
  • BG-I25589 Automatic designer: mode-names different to documentation
  • BG-I26386 Update Italian Calendar names
  • BG-I26417 Presence Control: output Pc not resetted with “off”
  • BG-I26370 Window: after Wp input Pc and Po no longer works continuous pulse
  • BG-I23136 Touch and Grill T5 missing from Room 2
  • BG-I26244 PLK calendar: typo fixed
  • BG-I26176 Virtual output does not automatically adapt type (analog/digital) after being connected
  • BG-I26142 Update of clients on a Gen.1 gateway fails due to less memory
  • BG-I26270 App Learning: Tree to Air Bridge re-appears in search results after creation
  • BG-I26291 Link caption displays wrong device count
  • BG-I26179 Default user right automatically gets re-added
  • BG-I26295 Page Banner overlay overlaps function blocks
  • A3D9-T649 added switchboard and installation location columns to diagnostic views
  • BG-I26119 closing a device diagnostic dialog didn’t stop the running diagnoses in all cases
  • A3D9-T557 view settings are now stored and reloaded for all compatible dialogs (device diagnostics, device learning, …)
  • Webengine view unable to load fonts from local resources (e.g. MessageCenter)
  • ProjectManagement view had incorrect font applied
  • centering of widgets/windows in parent didn’t work correctly in all cases
  • BG-I22968 updated Husqvarna Plugin v1.0.7
  • more logging
  • fixed potential auth issues
  • BG-I26067 Edit Settings dialog: visual identification context menu for unsupported devices
  • BG-I26011 Rooms from client not visible in user management
  • BG-I26117 Invalid page selection after closing search dialog
  • BG-I25946 No Color-Info for digital schedule
  • BG-I26140 Repair visibility of internal Air/Tree-IO’s
  • BG-I21204 Automatic Scene: invalid scene after adding project as client
  • BG-I24750 Intercommunication output send wrong value after SPS restart (may happen on client gateway systems)
  • BG-I26055 1-Wire last received timestamp not remanent
  • BG-I26024 Miniserver keeps coloured background in periphery tree after removing client object
  • BG-I26159 Caller not sent when text is too long
  • BG-I26204 HunterDouglas cant be added
  • BG-I26192 Statistic deletion interval of meters of a power supply & backup cant be set
  • BG-I25266 App Learning: No proper error in app when device is unable to be paired on a client
  • BG-I26219 Page tabs not updated after load from Miniserver
  • BG-I26189 Config connection via remote connect fails due to timeout
  • WA1-T426 Wallbox Air/Tree: Add systemmessage for supply voltage drop
  • BG-I26656 Access Keypad: auto connect UidLa to Uid of Wallbox
  • BG-I26381 opening air diagnostic dialog now only shows single route if air device is selected in document tree
  • Some device learning dialogs didn’t set modified flag when unlearning a device
  • BG-I18876 limiting data in GenericView to not grow infinitely and keep filtering performance up
  • BG-I26021 raising device diagnostic windows when showing warning that a device diagnostic is already running
  • BG-I25712 Intercommunication device wasn’t resolved correctly in UDP monitor for incoming packages
  • BG-I26523 tree branch in Tree learning dialog was named “right” for single internal branches
  • BG-I25530 improved key navigation directly from search input to table view in MyProjects view
  • BG-I26449 it is possible to delete Dali “Gruppe”
  • BG-I26572 Description of objects not used for reference drawing
  • BG-I25853 Touch Pure Flex: Degree sign takes up two characters
  • BG-I26530 App Learning: Devices don’t identify audible
  • BG-I26674 Login to Miniserver fails when previously connected to a Miniserver with same address
  • Wallbox and AC Control configuration dialog have untranslatable texts
  • Wallbox User not reset when charging is ended
  • BG-I26618 Air Base Channel Free Input does not have correct name
  • BG-I26591 LiveView can’t be stopped when ribbon is minimised
  • BG-I26703 PicoC Editor shows wrong string highlighting
  • BG-I26689 Connector window pops up when changing page while connection referencing
  • BG-I26509 Passwords to Miniservers now not contained anymore in files saved to Multiplicator Miniservers
  • BG-I25852 Touch Pure Flex: Allow asterisk in display text
  • BG-I26615 Status: comparing text with analogue values was not working properly
  • Object intercommunication fails after a power outage (Miniserver starts faster than the network)
  • BG-I26942 Frequency counter on digital input of Miniserver causes incorrect edges which causes incorrect values on metering function blocks
  • BG-I26522 Alarm History does not use description of alarm trigger instead name is always usedBG-I27011 Drag and drop of device causes visual glitches while doing auto connection
  • BG-I25582 Burglar Alarm: Confirming alarm resets window states set from parameter ‘Aoc’ which triggers alarm again
  • BG-I23915 Visualization shows data of last hour in the app in the first minutes after the full hour
  • Grill Thermometer shows offline error message even if online state is not monitored
  • Text Generator: Missing documentation textsBG-I26612 Climate controller dialog: change in prohibition settings changes settings on room controllers
  • BG-I26298 User management: user cannot be added to a group if the same group-uuid was imported from trust member
  • BG-I26952 Text generator: improved search for userid for trusted users
  • Belimo configure dialog: cursor jumps while verifying input
  • BG-I26317 Closing sequence dialog during running simulation stops sequence execution
  • BG-I23563 Alarm Central: disarm command unlocks Burglar Alarm Control
  • Freshly inserted Schedule objects now only contain Monday till Sunday operating modes per default
  • BG-I26670 Value correction could show -0 in some instances
  • BG-I26918 Wallbox missing when creating partlistBG-I26795 Invalid configured virtual output commands not working anymore
  • BG-I26718 Toilet Ventilation Controller: Doesn’t turn off again after a save to Miniserver
  • BG-I26784 Linked controls not shown in app
  • BG-I26868 Project Backups window renamed close buttonBG-I26762 EFM: Missing states after auto update (visualization not working)
  • BG-I26763 HTTP client didn’t return error to caller properly in all cases
  • BG-I26807 fixed possible value overflow when resetting values in Tree/Link diagnostics view
  • BG-I27191 Smoke & Water alarm: Texts do not use description of alarm trigger instead name is always used
  • BG-I27192 SD Test fills Miniserver SD card
  • BG-I27192 No error message when trying to update Miniserver but SD card is full
  • BG-I27109 SD Format: Better button texts for message box
  • BG-I27202 Warning message when saving new project to Miniserver is confusing
  • BG-I27114 Adding client project may create an invalid project
  • BG-I27223 Air learning: Removed deprecated IP column & time column is empty
  • BG-I26661 Memory flag shows invalid value in visualization
  • BG-I26946 Import Users: importing users with duplicate user-id possible
  • BG-I26973 Periphery Tree: duplicate Touch & Grill references
  • Text generator does not handle UserID fallback to username which is used by the NFC access
  • Allow more information for virtual http input
  • NFC Key and ID not in documentation
  • BG-I27175 Network search does not show actual type of found Miniservers
  • DALI AIR DALI search dialog bugfix
  • fixed DALI extension configuration data

Devices & Extensions

  • Air updates:
  • Fixed CRC error packets appearing 24 times in a row (Air monitor)
  • Broadcast update verification is now done separately to improve reliability and reduce traffic
  • Monitor packets for Air updates are now more descriptive
  • BG-I25481 AcControl: some Daikin S21 Aircons not communicating
  • BG-I26154 Touch Night Light Watchdog resets
  • BG-I25759 Touch Night Light Display briefly turned on after POR
  • BG-I21717: Nano IO and Nano Dimmer: improved touch handling
  • BG-I26173: Nano IO going offline
  • BG-I17870: Nano update fixed
  • New NFC Code Touch Binaries:
  • Better error checking during nfc learn mode (trust data not written correctly was not detected)
  • Better error logging
  • New Touch Pure Flex Binaries:
  • BG-I18724 Touch Flex time out of sync
  • BG-I26476 Valve Tree: actuators losing calibration data
  • New binaries (14.05.11.08) for Belimo Tree/Air (Fix: Startup error messages, Online state handling)
  • Dali Air: Conversion for devices created in older versions
  • BG-I26448 Ac Control Air: Mitsubishi Heavy Industries loses address of aircon
  • NFC Code Touch Tree: overhaul of NFC handling, quicker response and better diagnostics

Shading

  • BG-I26280 Dts handled incorrectly
  • BG-I17902 Automatic Jalousie does not fully close after manual slat position

Audio

  • BG-I26744 Audio Central: DisP not forwarded to Music Players
  • BG-I26540 Audio Central: Lock not forwarded to Music Players if DisPc is set at the same time
  • Miniserver Compact
  • TuneIn Ads Jingle removed
  • Prebuffering for Radio removed

Climate

  • BG-I22318 Climate Controller selection dialog: inherit-flags not set when using check all / uncheck all
  • BG-I26194 Intelligent Temperature Controller: fixed inconsistencies when using fahrenheit
  • BG-I26251 Intelligent Roomcontroller: invalid mode selected when current temperature is above heat protection
  • BG-I25940 Ac-Control: first target temperature not assigned
  • BG-I26096 Ac-Control: Invalid values on inputs(Mode,Fan,Adir) select next possible value
  • BG-I26013 Climate controller dialog: disable unassignable room controllers
  • BG-I26415 AC Control Air: invalid type-name after loading from miniserver
  • BG-I26383 IRC: Presence Button has no function when Dwc is active
  • BG-I26373 Disable heating/cooling ban not considered in calculating mode
  • BG-I26363 AC Control Air adds Vane 5 to Mitsubishi Electric
  • BG-I26553 IRC: invalid temperature info when window contact changes to off
  • BG-I26853 IRC: Prepare phase not started when fixed setpoint calendar entry
  • BG-I26842 Climate Control doesn’t save changes made by the “unselect everything” option
  • BG-I27134 Intelligent Room controller: learning of heat up times disabled by presence input
  • Intelligent Roomcontroller: Systemmessage “Big Difference” comes too early when comfort mode is started with presence

Lighting

  • BG-I26364 Hotel Light Controller: Remanence not working
  • BG-I25837 Lico does not detect Memory flag set to Smart
  • BG-I27070 Light controller: sequences not properly unmixed for moods with multiple sequences

Energy

  • BG-I26145 Spot Price Optimizer no status update sent to app after reset
  • BG-I26316 Wallbox Gen1: Output Cpl set to 0
  • BG-I26229 Modbus on Wallbox doesn’t pick up Modbus settings from template
  • BG-I26271 Spot Price Optimizer: Old limits are used when trigger is exactly at hour change
  • BG-I26271 Spot Price optimizer: Wrong categorization of values after a reboot
  • BG-I26395 Spot Price Optimizer: Show data source and unit next to spot market options
  • BG-I27065 Energy Manager causes Miniserver reboot when priority input is out of bounds
  • BG-I27066 Energy Manager: Assumes power is available when a load was activated by something else (That power is now not used anymore for calculation of the available managing power)
  • Wallbox: Connection fee provided by Manager not correctly set
  • BG-I26977 Wallbox displays wrong state in app
  • BG-I27053 Wallbox: charge limit not assigned via API-Connector
  • BG-I26044 Spot Price Optimizer: Spot source has problems with values at midnight in specific time zones

Multiplicator

  • BG-I26504 System schematic image not transferred to Miniserver
  • Connection flags missing when loading from Miniserver
  • BG-I26318 Audioserver added via program change not working
  • BG-I26792 Editing of global project settings may cause a config crash
  • BG-I27018 Language not changed when saving via Multiplicator project to the Miniserver

Trust

  • BG-I26273 Trust Member Miniserver version not set
  • BG-I26235 Trust Link does not use description for name of members
  • BG-I26269 Changes of transferred users not sent to trust
  • BG-I26269 Trust data not synchronised due to race conditions or high data load
  • Trust IO: Miniserver sends same command to a Miniserver multiple times
  • BG-I26372 Trust: Already created IOs shown again in the search
  • Trust: No proper internal name for created IOs
  • Miniserver now caches resolved clouddns address
  • This results in faster send of messages when a trust member is using clouddns
  • Trust Link Authentication more robust
  • User change from another Trust Member
  • Reverify the certificate from a Trust Member before using public key to improve security
  • BG-I26568 Trust search: Members not sorted
  • BG-I26917 Trust communication race condition causes Miniserver reboot

Belimo

  • BG-I26308 Belimo Air: IO’s not sorted alphabetically

Diagnostics

  • BG-I26103 Health Check description is used instead of name for some inserted items in tree view
  • BG-I26089 stopping air diagnosis were blocking Config for few seconds in some cases
  • BG-I26304 Air Diagnostics view was cleared when diagnosis has finished
  • BG-I26116 Diagnostic views had empty column filters for columns only showing an icon or checkbox
  • BG-I26016 Diagnostic views were missing Device type column content for device under diagnosis

Control History

  • Do not use device-source for certain device-types (Nano Di Tree, Air)
  • Show origin-control/device when using api commands
  • Invalid recalculation-entry on end of shading period
  • BG-I25976 Do not create locked-entry for short pulses
  • BG-I26321 Shading block floods with entries
  • BG-I26810 Auto Jalousie: History-Entry for preparing times written after saving remanence
  • Invalid source name directly after reboot

Project Planning

  • BG-I26327 LineIn-Id of created Audioserver not immediately set
  • BG-I26787 Wrong power was used for LED Spot WW PWM in calculation

Stability

  • BG-I26314 Config crash when editing light controller master colour
  • BG-I26290 Config crash when opening user management dialog
  • Several memory leaks
  • Miniserver reboots due to race conditions when updating user objects from trust
  • BG-I26525 Config crash when opening file
  • BG-I26233 Config crash when closing tree learning dialog
  • BG-I26214 Config crash in light controller dialog
  • BG-I26218 Config crash when selecting range in tree
  • BG-I24802 added possible fix for some crashes caused by System’s graphics driver in some rare cases
  • BG-I26622 Config crash when restoring template preset of intelligent room controller
  • BG-I26277 Crash when opening sequence control dialog
  • Several config crashes
  • Miniserver reboot when saving to Miniserver after Trust was deleted
  • Miniserver reboot when replacing device via app learning
Version: 14.5.12.7 Link
Receive Important Update Messages Stay tuned for upcoming Loxone Miniserver updates
The manufacturer Loxone has not yet set up its devicebase profile. Content such as updates, compatibilities and support may only be maintained with a delay.

Was the content helpful to you?